3. Configuration
9123-A2-GB20-20
August 2001
3-51
Session Access Level
Possible Settings: Level-1, Level-2, Level-3
Default Setting: Level-1
Specifies the highest security level allowed when accessing the menu-driven user
interface via a Telnet session. If a login is required for the session, the effective access
level is also determined by the user’s access level. When a login is
not required, the
effective access level is determined by this option. This option does not affect the TS
Access Management Link.
NOTE: The effective access level is always the lowest one assigned to either the
session or the user. For example, if the assigned Session Access Level is Level-2, but
the User Access Level is Level-3, then only level-3 access is allowed for the session.
Level-1 – Allows Telnet access by users with Login ID access levels of 1, 2, and 3, with
the capability to view system information, change configuration options, and run tests.
This is the highest access level allowed.
CAUTION: Before changing the session access level to Level-2 or 3, make sure that
the COM port’s Port Access Level is set to Level-1 and that at least one Login ID is set
to Level-1. Otherwise, access will be lost. If this occurs, you must reset the unit to the
factory defaults and begin the configuration process again. A reset is required if the
Communication Port’s Port Use option is set to Net Link (see
Level-2 – Allows Telnet access by users with Login ID access levels of 1, 2, and 3, with
the capability to view system information and run tests only; they cannot change
configuration options.
Level-3 – Allows Telnet access by users with Login ID access levels of 1, 2, and 3, with
the capability to view system information only; they cannot change configuration options
or run tests.
Inactivity Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Determines whether a Telnet session is disconnected after a specified period of keyboard
inactivity.
Enable – Terminates the session after the Disconnect Time expires.
Disable – Does not terminate Telnet session during inactivity.
Disconnect Time (Minutes)
Possible Settings: 1 – 60
Default Setting: 10
Sets the amount of keyboard inactive time allowed before a user session is disconnected.
Display Conditions – This option does not appear when Inactivity Timeout is disabled.
1 – 60 – Up to an hour can be set.
Table 3-12. Telnet and FTP Session Options (2 of 3)
Содержание FrameSaver FLEX 9123
Страница 1: ...FrameSaver FLEX 9123 User s Guide Document No 9123 A2 GB20 20 August 2001 ...
Страница 10: ...Contents viii August 2001 9123 A2 GB20 20 ...
Страница 24: ...1 About the FrameSaver FLEX 9123 1 10 August 2001 9123 A2 GB20 20 ...
Страница 34: ...2 User Interface and Basic Operation 2 10 August 2001 9123 A2 GB20 20 ...
Страница 98: ...3 Configuration 3 64 August 2001 9123 A2 GB20 20 ...
Страница 194: ...7 Setting Up OpenLane for FrameSaver Devices and Activating SLV Capability 7 10 August 2001 9123 A2 GB20 20 ...
Страница 212: ...8 Setting Up NetScout Manager Plus for FrameSaver Devices 8 18 August 2001 9123 A2 GB20 20 ...
Страница 228: ...A Menu Hierarchy A 6 August 2001 9123 A2 GB20 20 ...
Страница 258: ...B SNMP MIBs and Traps and RMON Alarm Defaults B 30 August 2001 9123 A2 GB20 20 ...
Страница 266: ...C Connectors Cables and Pin Assignments C 8 August 2001 9123 A2 GB20 20 ...