6. Troubleshooting
6-26
August 2001
9123-A2-GB20-20
Send and Monitor Pattern Tests
The pattern tests enable a FrameSaver unit to either send or monitor a known bit
pattern. These tests generate industry-standard bit patterns that can be used to
determine whether information is being correctly transmitted across a circuit.
The following test patterns are available:
A Send Pattern test cannot be started when the following tests are running:
Any Loopback on the same interface.
Send FT1 Loopback or Data Channel Loopback on the synchronous data port.
Procedure
To send and monitor a Pattern Test:
1. Select Network Physical Tests.
Main Menu
→
Test
→
Network Physical Tests
2. Select the desired pattern in the Send or Monitor field. If sending/monitoring a
user-defined pattern, enter the desired 2-byte hexadecimal value in the field
next to Send or Monitor.
When sending a pattern, the Inject ERR function key appears. Use Inject ERR
if you want to inject a bit error in the transmitted bit pattern.
3. Highlight the Send command to send a pattern, or the Start command to
monitor a pattern, and press Enter to start the test or start monitoring it.
4. View the length of time that the test has been running in the Results column.
An error count is also displayed. When monitoring a pattern, the ResetMon
virtual function key appears. ResetMon resets the error count to zero.
5. Highlight Stop and press Enter to stop the test.
6. View the length of time that the test has been running in the Result column.
—
QRSS
—
511
—
All-zeros
—
2047
—
All-ones
—
2E15-1 (215-1)
—
1-in-8
—
2E20-1 (220-1)
—
3-in-24
—
User-defined 2-byte test pattern (a0a0)
—
63
Содержание FrameSaver FLEX 9123
Страница 1: ...FrameSaver FLEX 9123 User s Guide Document No 9123 A2 GB20 20 August 2001 ...
Страница 10: ...Contents viii August 2001 9123 A2 GB20 20 ...
Страница 24: ...1 About the FrameSaver FLEX 9123 1 10 August 2001 9123 A2 GB20 20 ...
Страница 34: ...2 User Interface and Basic Operation 2 10 August 2001 9123 A2 GB20 20 ...
Страница 98: ...3 Configuration 3 64 August 2001 9123 A2 GB20 20 ...
Страница 194: ...7 Setting Up OpenLane for FrameSaver Devices and Activating SLV Capability 7 10 August 2001 9123 A2 GB20 20 ...
Страница 212: ...8 Setting Up NetScout Manager Plus for FrameSaver Devices 8 18 August 2001 9123 A2 GB20 20 ...
Страница 228: ...A Menu Hierarchy A 6 August 2001 9123 A2 GB20 20 ...
Страница 258: ...B SNMP MIBs and Traps and RMON Alarm Defaults B 30 August 2001 9123 A2 GB20 20 ...
Страница 266: ...C Connectors Cables and Pin Assignments C 8 August 2001 9123 A2 GB20 20 ...