COMSPHERE 6800 Series Network Management System
2-48
January 1997
6800-A2-GB31-20
Change Exception Reporting Thresholds (chert)
Use the chert command to set or change the failure thresholds for network tests supported by
exception reports. Exception reports are generated when parameters measured for DATAPHONE II
modems exceed the thresholds defined by this command. Results from the following commands
may be run through exception reporting:
Automatic Network Test (disruptive test)
Circuit Loss Inbound (disruptive test)
Circuit Loss Outbound (disruptive test)
Digital Test (disruptive test)
End-to-End Test (disruptive test)
Offline Test (disruptive test)
Receive Signal Level
Receive Signal Quality
Report Terminal Power
Signal Profile
For information about the measurements obtained by these commands, refer to the individual
command description in this chapter.
For most commands, NMS enables you to specify the destination for the command’s results and
schedule its execution. If the last page of the input form cannot accommodate the Destination for
results and Schedule execution fields, an additional page is provided. For a complete description
of these fields, refer to Chapter 1, Introduction.
Access Level:
Data Technician, Manager, System Administrator
Abbreviation:
chert
Restrictions:
None
Routine:
Yes
Schedule:
Yes
Related Commands: Display Exception Reporting Thresholds (dsert)
Exception Reports (er)
Change Exception Reporting Thresholds Input Forms
There are two pages for the Change Exception Reporting Thresholds input form.
Page 1
Page 1 displays the network test parameters for which exception reporting is applicable. For each
parameter, specify the threshold for which the results are to be reported.
Figure 2-13 is a sample of Page 1 of the Change Exception Reporting Thresholds input form.