ACCULINK 336x E1 NTU
E-18
June 1996
3360-A2-GB20-10
Table E-1
(3 of 4)
SNMP MIB to Front Panel Command Cross-Reference
Front Panel Command
SNMP MIB Object
Test–>Lpbk–>DCLB–>Prt
n
Test–>Lpbk–>Abort–>DCLB–>Prt
n
Set IfExtnsTestType for port
n to testFullDuplexLoopBack
Set dsx1LoopbackConfig for port
n to noTest
Test–>Lpbk–>DTLB–>Prt
n
Test–>Lpbk–>Abort–>DTLB–>Prt
n
Set IfExtnsTestType for port
n to testLoopDTLB
Set dsx1LoopbackConfig for port
n to noTest
Test–>Ptrns–>Send–>QRSS–>Prt
n
Test–>Ptrns–>Abort–>Send–>Prt
n
Set IfExtnsTestType for port
n to testSendQRS
Set IfExtnsTestType for port
n to noTest
Test–>Ptrns–>Send–>32767
Test–>Ptrns–>Abort–>Send–>NET
Set ifExtnsTestType for NET E1 to
testSend32767
Set ifExtnsTestType for NET E1 to
noTest
Test–>Ptrns–>Send–>1in8
Test–>Ptrns–>Abort–>Send–>NET
Set ifExtnsTestType for NET E1 to
testSend1in8
Set dsx1SendCode for NET E1 to
dsx1SendNoCode
Test–>Ptrns–>Send–>511–>Prt
n
Test–>Ptrns–>Abort–>Send–>Prt
n
Set IfExtnsTestType for port
n to testSend511
Set IfExtnsTestType for port
n to noTest
Test–>Ptrns–>Mon–>QRSS–>Prt
n
Test–>Ptrns–>Abort–>Mon–>Prt
n
Set ifExtnsTestType for port
n to testMonQRSS
Set ifExtnsTestType for port
n to noTest
Test–>Ptrns–>Mon–>511–>Prt
n
Test–>Ptrns–>Abort–>Mon–>Prt
n
Set ifExtnsTestType for port
n to testMon511
Set ifExtnsTestType for port
n to noTest
Test–>Ptrns–>Mon–>32767–>NET
Test–>Ptrns–>Abort–>Send–>NET
Set ifExtnsTestType for NET E1 to
testMon32767
Set dsx1SendCode for NET E1 to
dsx1SendNoCode
Cnfig–>Load Cnfig–>Save
Set devConfigAreaCopy to desired choice (Active to Customer1, etc.)
Cnfig–>Activ–>Edit–>DTE–>DTE–>Frame
Set/Display dsx1LineType for DTE E1 to
dsx1E1 or dsxE1-CRC
Cnfig–>Activ–>Edit–>DTE–>DTE–>Coding
Set/Display dsx1LineCoding for DTE E1 to
dsx1HDB3 or dsx1AMI
Cnfig–>Activ–>Edit–>Port–>Prtn->Port Type
Display rs232PortType for port
n to rs422, v35, or X.21
Cnfig–>Activ–>Edit–>Port–>Prt
n–>TxClock
Set/Display rs232SyncPortClockSource for port
n to internal or
external
Cnfig–>Activ–>Edit–>NET–>NET Frame
Set/Display dsx1LineType for NET E1 to
dsx1E1 or dsxE1-CRC
Cnfig–>Activ–>Edit–>NET–>Mgmt Link
Set/Display dsx1Fdl for NET E1 to
dsx1other or dsx1FDL-none