background image

1

Hotwire

®

 ReachDSL

 v1 (MVL

®

) Modem, 

Model 6310-A4, with Inline Phone Filter 
Installation Instructions

Document Number 6310-A2-GN12-00

September 2001

Contents 

Hotwire 6310 ReachDSL v1 (MVL) Modem Overview

..................................

1

Getting Started

..............................................................................................

4

Installing the Hotwire 6310 ReachDSL v1 Modem

.......................................

5

Power-On

......................................................................................................

8

Troubleshooting

.............................................................................................

9

HomeLink (for ReachDSL v1 Modems Only)

................................................ 10

Increasing the Number of End-User Systems

.............................................. 10

Cables & Connectors

.................................................................................... 11

Optional ReachDSL Modem Wall Placement

............................................... 13

Technical Specifications for Hotwire 6310 ReachDSL v1 Modem

................ 15

Important Safety Instructions

........................................................................ 16

Warranty, Sales, Service, and Training Information

...................................... 21

Hotwire 6310 ReachDSL v1 (MVL) Modem Overview

The Hotwire

®

 6310 ReachDSL

 version 1 (formerly MVL

®

) Modem is a component in 

the Hotwire ReachDSL System and interoperates with the Hotwire 8310 MVL, or 
Hotwire 8312/8314 ReachDSL Card in the DSLAM (Digital Subscriber Line Access 
Multiplexer) system. This system provides high-speed Internet or corporate LAN access 
over traditional twisted-pair copper telephone wiring.

The ReachDSL technology:

„

Utilizes an inline phone filter on the ReachDSL modem’s PHONE jack.

„

Operates over existing copper wire with existing telephone jacks.

„

Includes a second line pass-through from the ReachDSL modem’s LINE jack to 
PHONE jack to accommodate an attached 2-line telephone.

„

Provides rate adaptive data rates to dynamically adapt and allocate bandwidth to 
optimize applications.

Содержание 6310

Страница 1: ...twire 6310 ReachDSL v1 MVL Modem Overview The Hotwire 6310 ReachDSL version 1 formerly MVL Modem is a component in the Hotwire ReachDSL System and interoperates with the Hotwire 8310 MVL or Hotwire 8312 8314 ReachDSL Card in the DSLAM Digital Subscriber Line Access Multiplexer system This system provides high speed Internet or corporate LAN access over traditional twisted pair copper telephone wir...

Страница 2: ...stomer premises at the demarcation point NOTES In this document A telephone is used to represent any equipment that plugs into a phone jack and uses the POTS line such as a phone modem or fax machine End user system is used to represent any PC with an Ethernet connection and ReachDSL based service RJ11 wall jack is used to represent either an RJ11 or an RJ14 wall jack The RJ14 wall jack is used fo...

Страница 3: ...hone Filter is designed for use with a wall phone Product Related Documents To install a phone filter refer to the appropriate document Contact your sales or service representative to order additional product documentation Paradyne documents are available on the World Wide Web at www paradyne com Select Library Technical Manuals Hotwire DSL Systems Document Number Document Title 6035 A2 GN11 Hotwi...

Страница 4: ...arranty at www paradyne com warranty Wiring and Cables You Need The following wiring and standard connectors are used with this product Standard RJ11 or RJ14 wall jack for the ReachDSL modem cabling Standard Ethernet 8 pin non keyed modular plug for a PC or workstation An Ethernet straight through or crossover cable is used Refer to Installing the Hotwire 6310 ReachDSL v1 Modem on page 5 for Ether...

Страница 5: ...ed in Step 1 into the jack labeled PHONE 3 Use the supplied RJ11 6 pin interface cable for the LINE connection Insert one end of the cable into the jack labeled LINE Insert the other end of the cable into the RJ11 wall jack NOTE If you are installing a POTS splitter with another telephone connect the telephone to the jack labeled PHONE then connect the jack labeled LINE to a wall jack Do NOT plug ...

Страница 6: ...o a hub s Uplink connection use an Ethernet crossover cable or Use an Ethernet crossover cable and connect the other end to a PC with an Ethernet Network Interface Card NIC installed PHONE LINE ETHERNET POWER 01 17008 Ethernet Line Ethernet Hub 8 7 6 5 4 3 2 1 Ethernet Straight Through Cable 01 17009 Ethernet Line PC with Ethernet Network Interface Card Ethernet Crossover Cable PHONE LINE ETHERNET...

Страница 7: ...ck labeled POWER Plug the transformer into an AC outlet The ReachDSL modem hardware installation is now complete When the power cord is installed the ReachDSL modem goes through a power on self test PHONE LINE ETHERNET POWER 01 17010 Power Jack Transformer or ...

Страница 8: ...SL modem has power ALM OFF ON No active alarms An alarm condition exists TST OFF ON No active tests The TST LED is on during the power on self test and during a test initiated by the service provider LINE ON OFF The DSL link is active and ready to transmit and receive data The DSL link has not been established TX RX ON OFF Data transmission is in progress on the DSL line The modem is not transmitt...

Страница 9: ... contact the service provider Verify that the line has dial tone If there is no dial tone contact the service provider LINE LED is on and there is no data transmission The DSL link has been established but there is no data transmission Verify the Ethernet connection If the problem persists contact the service provider LINE and Ethernet LEDs are on and there is no data transmission The DSL line and...

Страница 10: ...tem multiple end user systems can share resources including File sharing Print sharing Secondary computer backup To enable the sharing of resources and review security considerations see Microsoft s Web site at www microsoft com In this example of HomeLink the PC in the family room could use the office printer Increasing the Number of End User Systems A single end user system is attached to the Ho...

Страница 11: ...14 6 pin connectors can be used Line Phone Connectors The LINE and PHONE jack pinouts are either filtered or unfiltered for POTS Pin Function 1 Not used 2 Ring 2 optional 3 DSL Ring 1 4 DSL Tip 1 5 Tip 2 optional 6 Not used PHONE Jack Pinouts LINE Jack Pinouts Pin 3 4 Filtered for POTS Pin 3 4 DSL and POTS Pin 2 5 2nd POTS unfiltered Pin 2 5 2nd line pass through 98 15304a 6 Pin RJ11 Plugs Pin 1 P...

Страница 12: ...tion 1 10BaseT TX D 2 10BaseT TX D 3 10BaseT RX D 4 5 Not used 6 10BaseT RX D 7 8 Not used 98 16055a 8 Pin Plug Ethernet Cable Pin 1 Pin 8 10 100BaseT TX D 10 100BaseT TX D 10 100BaseT RX D Not Used Not Used 10 100BaseT RX D Not Used Not Used 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 10 100BaseT TX D 10 100BaseT TX D 10 100BaseT RX D Not Used Not Used 10 100BaseT RX D Not Used Not Used Function Pin Function...

Страница 13: ...and 3 16 drill bit for the plastic anchors Screwdriver A template with the dimensions for the two screws is provided See ReachDSL Modem Hardware Template on page 14 Procedure To mount the Hotwire 6310 ReachDSL v1 Modem 1 Use a drill to install the plastic anchors 2 Use a screwdriver to install the screws Do not install the screws flush with the wall Leave enough clearance to hang the modem housing...

Страница 14: ...14 ReachDSL Modem Hardware Template 5 10 01 17014 Top Bottom ...

Страница 15: ... 15 CISPR 22 Other Certifications Class B digital device Class B Refer to equipment s label for approvals on product Physical Environment Operating temperature Storage temperature Relative humidity Shock and vibration 32 F to 104 F 0 C to 40 C 22 F to 158 F 30 C to 70 C 5 to 95 noncondensing Withstands normal shipping and handling Heat Dissipation 2 35 watts at 5 0 VDC nominal input voltage Interf...

Страница 16: ...tion authorities to ensure compliance 7 A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in separate buildings are interconnected the voltage potential may cause a hazardous condition Consult a qualified electrical consultant to determine whether or not this phenomenon exists and if necessary implement corrective action prior...

Страница 17: ...pproximation of the laws of the member states relating to Electro Magnetic Compatibility EMC as amended by Directive 93 68 EEC CANADA EMI NOTICE This Class B digital apparatus meets all requirements of the Canadian interference causing equipment regulations Cet appareil numérique de la classe B respecte toutes les exigences du réglement sur le matérial brouilleur du Canada Japan Notices This is a ...

Страница 18: ...essly approved by Paradyne Corporation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordan...

Страница 19: ...e telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice is not practical the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary 5 The telephone company may make changes in its facilities equipment operations or proc...

Страница 20: ...method of connection The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request to di...

Страница 21: ... Document Feedback We welcome your comments and suggestions about this document Please mail them to Technical Publications Paradyne Corporation 8545 126th Ave N Largo FL 33773 or send e mail to userdoc paradyne com Include the number and title of this document in your correspondence Please include your name and phone number if you are willing to provide additional clarification Trademarks Hotwire ...

Страница 22: ......

Страница 23: ......

Страница 24: ... 6310 A2 GN12 00 ...

Отзывы: