background image

1

SMD2000-24T 24-Port SHDSL Mini DSLAM

Installation Instructions

Document Number SMD2-A2-GN11-00

July 2005

Contents

Software and Firmware License Agreement

.................................................

2

Product Documentation Online

.....................................................................

3

Unpacking and Inspecting the Equipment

....................................................

4

Site Selection Criteria

...................................................................................

4

Installing Uplink Interface Modules (Optional)

..............................................

5

Tabletop Installation

......................................................................................

7

Rack Installation

............................................................................................

8

Powering Up the SMD2000-24T

...................................................................

9

Connecting the SHDSL RJ21 Cable

............................................................. 11

Connecting to the Remote SHDSL Modems

................................................ 12

Verifying the Connection(s)

........................................................................... 13

Connecting the Uplink Lines

......................................................................... 14

Default Settings

............................................................................................. 15

Data Storage

................................................................................................. 17

Reset Button

................................................................................................. 19

LED Indicators

.............................................................................................. 20

Pin Assignments

........................................................................................... 23

Technical Specifications

................................................................................ 26

EMI Notices

.................................................................................................. 27

ACTA Customer Information

......................................................................... 27

CE Marking

................................................................................................... 28

Japan Notice

................................................................................................. 29

Important Safety Instructions

........................................................................ 30

Warranty, Sales, Service, and Training Information

...................................... 31

Содержание 24-Port SHDSL Mini DSLAM SMD2000-24T

Страница 1: ...ptional 5 Tabletop Installation 7 Rack Installation 8 Powering Up the SMD2000 24T 9 Connecting the SHDSL RJ21 Cable 11 Connecting to the Remote SHDSL Modems 12 Verifying the Connection s 13 Connecting the Uplink Lines 14 Default Settings 15 Data Storage 17 Reset Button 19 LED Indicators 20 Pin Assignments 23 Technical Specifications 26 EMI Notices 27 ACTA Customer Information 27 CE Marking 28 Japa...

Страница 2: ... notice to Paradyne and an agreement in writing to additional terms 3 The Licensee shall not reverse engineer decompile or disassemble the Software in whole or in part 4 The Licensee shall not copy the Software except for a single archival copy 5 Except for the Product warranty contained in the manual the Software is provided AS IS and in its present state and condition and Paradyne makes no other...

Страница 3: ... not be assigned sublicensed or otherwise transferred by the Licensee to any third party without the prior written consent of Paradyne 8 This Agreement and the license granted under this Agreement shall be terminated in the event of breach by the Licensee of any provisions of this Agreement 9 Upon such termination the Licensee shall refrain from any further use of the Software and destroy the orig...

Страница 4: ...our sales representative Site Selection Criteria In choosing a location for the installation of this product Select a restricted access area where admittance is limited to trained and authorized service personnel Ensure that the internal temperature of a rack containing this equipment will not exceed the maximum recommended ambient temperature of 149 F 65 C Place the chassis such that connecting c...

Страница 5: ...requires an Ethernet uplink connection or if you require an additional E1 or T1 backhaul The SMD2000 24T supports the following 1 port UIMs only UIM E1 UIM T1 UIM 10 100 CAUTION Disconnect all power sources from the SMD2000 before installing a UIM Procedure To install a UIM 1 Remove the Chassis Cover Using a Phillips Screwdriver remove the eight flathead screws securing the SMD2000 24T chassis cov...

Страница 6: ...he lip of the SMD2000 24T faceplate at the selected port opening such that the UIM PCB is face down and the UIM label shows through the port opening with the UIM model name along the right edge 4 Align and secure the PCBs Ensure that the connector key pins and the four mounting holes on the UIM PCB are lined up with the board to board connector and the four corresponding standoffs on the SMD2000 2...

Страница 7: ...ginal eight flathead screws as depicted in Step 1 on page 5 Tabletop Installation Procedure To install the SMD2000 24T on a table desk shelf or remote cabinet 1 Affix the four provided rubber pads to the bottom of the chassis for surface grip 2 Place the SMD2000 24T such that the cables will not become a tripping hazard or pull loose from the chassis Ensure that the air supply vents on the sides o...

Страница 8: ...he chassis onto the rack and secure the rack mount brackets to the sides of the rack using one of the two provided sets of four rack mount screws whichever size fits the rack being used 3 Check the rack for stability ensuring that installation of the SMD2000 24T has not caused the rack to become top heavy Ensure that all cables are secured such that they will not become a tripping hazard or pull l...

Страница 9: ...ur ground wire with the two holes on the small unpainted section on the left side of the back of the chassis Secure the terminal lug to the chassis with two 10 32 screws 2 Connect the other end of the ground wire to a frame ground This can vary from location to location but typically all equipment in a Central Office is grounded to a common copper bus 3 Select a terminal block Either terminal bloc...

Страница 10: ...the screw into the terminal block same terminal from which it was removed 5 Remove the right hand screw labeled from the same terminal block slide the ring terminal of your negative lead onto the shaft of the screw and re insert the screw into the terminal block same terminal from which it was removed CAUTION Be sure to attach the positive lead to the positive terminal and the nagative lead to the...

Страница 11: ...s However if you wish to run subscriber lines at settings other than the SMD2000 24T defaults configure the subscriber lines prior to connection Parameter settings may be changed using the Command Line Interface CLI Simple Network Management Protocol SNMP or the web based management system SHDSL Parameter Defaults on page 15 lists the device defaults Product Documentation Online on page 3 lists th...

Страница 12: ...0 or 180 degree cable both the left and right sides of the RJ21 plug connector should be secured to the socket Connecting to the Remote SHDSL Modems A primary feature of the SMD2000 24T is its capability to support multiple loop bonded SHDSL connections However it is equally capable of supporting up to 24 single line connections as well as combinations of both single and loop bonded connections Lo...

Страница 13: ...onfigured prior to connection if you intend to run the group with parameter settings other than the defaults Single Line SHDSL Connection A single line SHDSL subscriber connection may be established with any standard SHDSL subscriber equipment Verifying the Connection s The LK link LED for each port connected with a remote modem will flash green to indicate a connection has been established An ACT...

Страница 14: ... requires only one uplink connection for operational purposes although a second T1 uplink connection may be desired for redundancy Additionally the two T1 uplink ports may be bonded together for a single connection as long as the remote T1 equipment is loop bonding capable Refer to Product to Product T1 Loop Bonding Compatibility Document Number COMP A2 GK44 for a list of loop bonding capable prod...

Страница 15: ...0 0 Protocol All Speed 272 kbps VLAN Priority 0 none VLAN Range 0 0 off Table 2 T1 Defaults Parameter Default Frame Type Extended Super Frame ESF Line Attenuation 0 dB Line Code Bipolar with 8 Zero Substitution B8ZS Speed n a T1 uplink speed is determined via communication with the remote T1 provider equipment to which the SMD2000 24T is connected Timing Speed and timing are non configurable param...

Страница 16: ...anagement VLAN ID 0 off TFTP Trivial File Transfer Protocol on Management IP Address Filter Range 0 0 0 0 255 255 255 255 all Uplink DSLAM Interconnection 1 neither off Table 4 Username and Password Defaults Username Passwords Access Username Usernames and passwords are case sensitive Password read write superuser Password read only general Password Table 5 SNMP Access Defaults Community String Ac...

Страница 17: ... loses power unless deliberately cleared or reconfigured Saving to Local Files SMD2000 24T management and port configurations can be uploaded to a local file on your PC or local network via the Trivial File Transfer Protocol TFTP GET command Configuration files can also be downloaded from a local file to an SMD2000 24T with a TFTP PUT command Refer to your TFTP program s help for further instructi...

Страница 18: ... 4 6 8 A dash indicated range nvr_portcfg bin Password 1 6 12 Or using the keyword all nvr_portcfg bin Password 1 all Table 7 Template Criteria Item Data Needed for Backup Example Host Name DSLAM_IP Address xxx xxx xxx xxx 193 166 254 98 Remote Filename NVR_CFG BIN superuser password nvr_cfg bin Password Local Filename user preference smd2000_template bin Table 8 Template Criteria Item Data Needed...

Страница 19: ...al default settings To clear the system press the Reset Button for one second release and within five 5 seconds press the Reset Button again for one second After the first pressing of the Reset Button the passage of five seconds is indicated by the successive flashing of the SHDSL Link LK LEDs for Ports 1 5 if you do not press the Reset Button a second time within the allotted five seconds the SMD...

Страница 20: ...ss constant rate Table 9 LEDs 1 of 3 State Indication Additional Information PWR power Solid green SMD2000 24T is receiving power Both power terminals are connected Solid amber SMD2000 24T is receiving power One of the two power terminals is connected No illumination No power If the SMD2000 24T is not receiving power none of the LEDs will be illuminated FAN Solid green All four fans are fully func...

Страница 21: ...it does not pertain to remote network access of the SMD2000 24T LK T1 Uplink Port 1 and 2 Flashing green T1 uplink connection is established and active The uplink port has received valid data from the remote T1 provider equipment within the last second Solid green T1 uplink connection is established A T1 uplink connection exists and the port may be transmitting but it has not received any data fro...

Страница 22: ...ipment has lost a connection with an intermediate device and is in Red or Yellow Alarm SHDSL LK Ports 1 24 Flashing green SHDSL connection is established and active The port has received valid data from the remote SHDSL modem within the last second Solid green Problematic SHDSL connection A connection exists but there is indication of a problem with the SHDSL line No illumination No SHDSL connecti...

Страница 23: ...tor Pins Ring Tip Port 1 1 26 Port 13 13 38 Port 2 2 27 Port 14 14 39 Port 3 3 28 Port 15 15 40 Port 4 4 29 Port 16 16 41 Port 5 5 30 Port 17 17 42 Port 6 6 31 Port 18 18 43 Port 7 7 32 Port 19 19 44 Port 8 8 33 Port 20 20 45 Port 9 9 34 Port 21 21 46 Port 10 10 35 Port 22 22 47 Port 11 11 36 Port 23 23 48 Port 12 12 37 Port 24 24 49 ...

Страница 24: ...Ethernet RJ45 Connection Pin Connection 1 Rx 2 Rx 3 Tx 4 not used 5 not used 6 Tx 7 not used 8 not used Table 12 T1 RJ48C Pin Assignments Pin Function Pin 1 Rx Ring Pin 2 Rx Tip Pin 3 not used Pin 4 Tx Ring Pin 5 Tx Tip Pin 6 not used Pin 7 not used Pin 8 not used ...

Страница 25: ...n Pins not shown are unused Table 13 DB9 to 8 Pin Modular Adapter Pinouts Pin 8 Pin Modular Port Direction PC RS232 Serial Port Pin 1 Transmit Data TxD RxD Receive Data 2 2 Data Set Ready DSR RTS Request to Send 7 4 Receive Data RxD TxD Transmit Data 3 5 Ground GND GND Ground 5 6 Data Terminal Ready DTR CTS Clear to Send 8 ...

Страница 26: ...RE EMC FCC Part 15 CSA C108 8 EN55022 EN55024 Safety UL 1950 CSA C22 2 No 950 EN60950 CE Marking Environment Operating Temperature 40 F to 149 F 40 C to 65 C Storage Temperature 40 F to 158 F 40 C to 70 C Humidity 5 to 95 Non condensing Altitude 200 ft to 16 500 ft 60 m to 5 000 m Interfaces 24 SHDSL ports 1 RJ21 50 pin Telco 2 fixed RJ48C T1 uplink ports 1 RJ45 10 100BaseT management interface 1 ...

Страница 27: ...s A digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe A est conforme à la norme NMB 003 du Canada ACTA Customer Information This equipment complies with Part 68 of the FCC rules and the requirements adopted by the Administrative Council for Terminal Attachments ACTA On the bottom of the network extender is a label that contains among other information a product ...

Страница 28: ...ive or distributor directly for any help needed For additional information concerning warranty sales service repair installation documentation training distributor locations or Paradyne worldwide office locations use one of the following methods Internet Visit the Paradyne World Wide Web site at www paradyne com Be sure to register your warranty at www paradyne com warranty Telephone Call our auto...

Страница 29: ...n the standard of the Voluntary Control Council for interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions ...

Страница 30: ...e phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in separate buildings are interconnected the voltage potential may cause a hazardous condition Consult a qualified electrical consultant to determine whether or not this phenomenon exists and if necessary implement corrective action prior to interconnecting the products 8 Input powe...

Страница 31: ... documentation training distributor locations or Paradyne worldwide office locations use one of the following methods Internet Visit the Paradyne World Wide Web site at www paradyne com Be sure to register your warranty at www paradyne com warranty Telephone Call our automated system to receive current information by fax or to speak with a company representative Within the U S A call 1 800 870 222...

Страница 32: ...32 SMD2 A2 GN11 00 SMD2 A2 GN11 00 ...