ZX82-EI02 01/2019
PARADOX.COM
ZX82
8-Zone Input
Expansion Module
Installation Manual
V1.10 and higher
Introduction
The ZX82, 8-zone Expansion Module, provides 8 zones input expansion to
Paradox panels; connects on the keypad bus of EVO, Spectra, or MG
panels. The ZX82 comes with its own
tamper-proof
enclosure and provides
Zone Status LED indicators as well as Power and Data.
Compatibility
•
All Paradox control panels v6.80 or higher
•
BabyWare v5.1 and higher
•
Infield v5.1 and higher
Connections
Connect the four bus terminals labeled
+ -
GRN
YEL
of the module to the
corresponding terminals on the control panel as shown.
To enable anti-tamper switch input on EVO, use input terminal Z8 and enable
section
[001]
option
[1]
.
To enable anti-tamper switch input on MG/SP, use input terminal Z1 and enable
section
[706]
option
[4]
for panel +1, option
[5]
for panel +9 and option
[6]
for
panel +17.
Upgrading Firmware
The ZX82’s
firmware can be upgraded in Infield via BabyWare using a
307USB Direct Connect Interface.
LED Indicators
*If control panel has an AC Loss all LEDs are turned off.
Technical Specifications
* Control Panel shall be certified to EN 50131-6 and used as the power supply
for the expansion module. If an external power supply is used, it must be
certified for EN 50131-6.
The security grade of the ZX82 is dependent on the security grade of the
system where it is installed. The maximum security grade is 3.
External Anti-Tamper
Switch (N.C.)
LED
OFF
ON
POWER
OFF
OK (10.5V to 16V)
RX / TX
No clock or data
exchange
Clock and data OK
ZONE1 to ZONE8*
Zone Closed
Zone Opened /
Tamper
ATZ Enabled on EVO
ZONE1 to ZONE8
Both zones connected
to this input are Closed
Any Zone connected
to this input is
Opened / Tamper
Input Voltage
10.5 to 16 Vdc
Current Consumption
100mA MAX all LEDs On
Number of Inputs
8 standard zone inputs
Operating Temperature
-20 C to +50 C (-4 F to 122 F)
Humidity
95% maximum
Dimensions (H x W x D)
16.5 cm x 10.2 cm x 2.5 cm
(6.5 in x 4 in x 1 in)
Certification*
CE, EN 50131-3 Security Grade: 3
Environmental Class: II
Certification Body: Applica Test and
Certification AS
Display
Power
Lock
Data
All manuals and user guides at all-guides.com