Figure 1: ZX8 Connections
The 8-zone Expansion Module (ZX8) is an interface between the control
panels and any hardwired detection devices. The ZX8 connects to the
control panel's combus to provide eight additional hardwired inputs
and one 50mA on-board PGM output.
Specifications
Installation
Connect the module as shown in Figure 1.
Table 1: Jumper Setting
Table 2: Illustration
DiDigiplex EVO
A “Locate” request coming from the control panel can be disabled by pressing the “Disable Locate”.
MG/SP Series
Press the “Disable Locate” for 3 seconds. Fast flash of the green LED occurs. Jumper settings can be changed.
Green “LOC” LED
Digiplex and Digiplex EVO
Remains Illuminated during power up
Flashes fast to indicate it is receiving a “Locate” request from the control panel. To disable a “Locate” request, press the “Disable Locate” switch.
SP Series and MG5050
Flashes fast to indicate a change in jumper setting.
Red “WDG” LED
All panels
Flashes to indicate proper operation
If both “LOC” and the “WDG” LED are flashing alternately, the module is
experiencing a communication failure with the control panel.
Connect the detection devices to the ZX8 input terminals exactly as shown in the appropriate control panel’s
Programming Guide
.
Digiplex y Digiplex EVO
Z8: Input terminal Z8 can be used as an anti-tamper switch input. Enable
section [001] option [1]
MG/SP Series
Z1: Input terminal Z1 can be used as an anti-tamper switch input. Enable
section [706] option [4] for panel+1, option [5] for panel+9 and option [6] for panel+17
Input voltage:
Typically 12 to 16 Vdc
Current cons.:
28mA
Max.# of ZX8:
max.3: MG/SP Series
No. of outputs:
One 50mA PGM
No. of inputs:
8 inputs
No. of zones:
8 standard zone inputs
Oper. temperature:
-20ºC to 50ºC (-4ºF to 122ºF)*
Compatibility:
Any Digiplex or Digiplex EVO series control panel
Any SP Series control panel (V2.0 or higher)
MG5000/MG5050 control panels (V2.0 or higher)
WinLoad Software V2.03 or higher
NOTE:
For 1728/1738 compatibility, refer to the
SP-ZX8 instructions.
MG5000
(2 on-board zones)
MG5050
(5 on-board zones)
SP4000
(4 on-board zones)
SP5500
(5 on-board zones)
SP6000
(8 on-board zones)
SP65
(9 on-board zones)
SP7000
(16 on-board zones)
No/
ATZ
ZTA
With/
ATZ
ZTA
No/
ATZ
ZTA
With/
ATZ
ZTA
No/
ATZ
ZTA
With/
ATZ
ZTA
No/
ATZ
ZTA
With/
ATZ
ZTA
No/
Sin/Sans
ATZ
ZTA
With/
Con/Avec
ATZ
ZTA
No/
Sin/Sans
ATZ
ZTA
With/
Con/Avec
ATZ
ZTA
No/
Sin/Sans
ATZ
ZTA
With/
Con/Avec
ATZ
ZTA
zones/
zones/
zones/
zones/
zones/
zones/
zones/z
A / Panel+1*
3-10
5-12
6-13
11-18
5-12
9-16
6-13
11-18
9-16
17-24
10-17
19-26
17-24
-
B / Panel+9*
11-18
13-20
14-21
19-26
13-20
17-24
14-21
19-26
17-24
25-32
18-25
27-32
25-32
-
C / Panel+17*
19-26
21-28
22-29
27-32
21-28
25-32
22-29
27-32
25-32
-
26-32
-
-
-
*
Press “Disable Locate” for 3 seconds to change jumper setting
A
B
C
D
External
Anti-Tamper
Switch (N.C.)
ZX8-TI03