8-Zone Expansion Modules

ZX8

V6.0

Instructions / Instrucciones

PARADOX.COM

Printed in Canada - 05/2014

Figure 1: ZX8 Connections

The 8-zone Expansion Module (ZX8) is an interface between the control
panels and any hardwired detection devices. The ZX8 connects to the 
control panel's combus to provide eight additional hardwired inputs 
and one 50mA on-board PGM output.

Specifications

Installation

Connect the module as shown in Figure 1.

Table 1: Jumper Setting

Table 2: Illustration

DiDigiplex EVO

A “Locate” request coming from the control panel can be disabled by pressing the “Disable Locate”. 

MG/SP Series

Press the “Disable Locate” for 3 seconds. Fast flash of the green LED occurs. Jumper settings can be changed.

Green “LOC” LED

Digiplex and Digiplex EVO
Remains Illuminated during power up
Flashes fast to indicate it is receiving a “Locate” request from the control panel. To disable a “Locate” request, press the “Disable Locate” switch. 

SP Series and MG5050

Flashes fast to indicate a change in jumper setting.

Red “WDG” LED

All panels
Flashes to indicate proper operation

If both “LOC” and the “WDG” LED are flashing alternately, the module is 
experiencing a communication  failure with the control panel.
Connect the detection devices to the ZX8 input terminals exactly as shown in the appropriate control panel’s 

Programming Guide

.

Digiplex y Digiplex EVO

Z8: Input terminal Z8 can be used as an anti-tamper switch input. Enable 
section [001] option [1]

MG/SP Series

Z1: Input terminal Z1 can be used as an anti-tamper switch input. Enable 
section [706] option [4] for panel+1, option [5] for panel+9 and option [6] for panel+17

Input voltage:

Typically 12 to 16 Vdc

Current cons.:

28mA

Max.# of ZX8:

max.3: MG/SP Series

No. of outputs:

One 50mA PGM

No. of inputs:

8 inputs

No. of zones:

8 standard zone inputs

Oper. temperature:

-20ºC to 50ºC (-4ºF to 122ºF)*

Compatibility:

Any Digiplex or Digiplex EVO series control panel
Any SP Series control panel (V2.0 or higher)
MG5000/MG5050 control panels (V2.0 or higher)
WinLoad Software V2.03 or higher

NOTE:

 For 1728/1738 compatibility, refer to the 

SP-ZX8 instructions.

MG5000

(2 on-board zones)

MG5050

(5 on-board zones)

SP4000

(4 on-board zones)

SP5500

(5 on-board zones)

SP6000

(8 on-board zones)

SP65

(9 on-board zones)

SP7000

(16 on-board zones)

No/

ATZ 
ZTA

With/

ATZ
ZTA

No/

 

ATZ
ZTA

With/

ATZ
ZTA

No/

 

ATZ
ZTA

With/

ATZ

 ZTA

No/

 

ATZ
ZTA

With/

ATZ
ZTA

No/

Sin/Sans 

ATZ
ZTA

With/

Con/Avec 

ATZ

 ZTA

No/

Sin/Sans 

ATZ
ZTA

With/

Con/Avec 

ATZ

 ZTA

No/

Sin/Sans 

ATZ

 ZTA

With/

Con/Avec 

ATZ 
ZTA

zones/

zones/

zones/

zones/

zones/

zones/

zones/z

A / Panel+1*

3-10

5-12

6-13

11-18

5-12

9-16

6-13

11-18

9-16

17-24

10-17

19-26

17-24

-

B / Panel+9*

11-18

13-20

14-21

19-26

13-20

17-24

14-21

19-26

17-24

25-32

18-25

27-32

25-32

-

C / Panel+17*

19-26

21-28

22-29

27-32

21-28

25-32

22-29

27-32

25-32

-

26-32

-

-

-

*

Press “Disable Locate” for  3 seconds to change jumper setting

 