The 8-zone Expansion Module (ZX8) is an interface between the control panels and any hardwired detection devices. The ZX8 connects to the control panel's combus 

to provide eight additional hardwired inputs and one 50mA on-board PGM output.

Specifications

Installation

Connect the module as shown in Figure 1.

Table 1: Illustration

Table 2: Jumper Setting

Table 3: Options

Input voltage:

Typically 12 to 16 Vdc

No. of zones:

8 standard zone inputs

Current cons.:

28mA

Oper. temperature:

-20ºC to 50ºC (-4ºF to 122ºF)*

Max.# of ZX8:

max.3: MG/SP Series

Compatibility:

Any Digiplex or Digiplex EVO series control panel

Any SP Series control panel (V2.0 or higher)

MG5000/MG5050 control panels (V2.0 or higher)

WinLoad Software V2.03 or higher

NOTE: For 1728/1738 compatibility, refer to the ZX8SP instruc-

tions.

No. of outputs:

One 50mA PGM

No. of inputs:

8 inputs

A DiDigiplex EVO

A “Locate” request coming from the control panel can be disabled by pressing the “Disable Locate”. 

MG/SP Series

Press the “Disable Locate” for 3 seconds. Fast flash of the green LED occurs. Jumper settings can be changed.

B Green “LOC” LED

Digiplex and Digiplex EVO

Remains Illuminated during power up

Flashes fast to indicate it is receiving a “Locate” request from the control panel.

To disable a “Locate” request, press the “Disable Locate” switch.

SP Series and MG505

0

Flashes fast to indicate a change in jumper setting.

Red “WDG” LED

All panels flashes to indicate proper operation 

If both “LOC” and the “WDG” LED are flashing alternately, the module is experiencing a communication  failure with the control panel.

C

Connect the detection devices to the ZX8 input terminals exactly as shown in the appropriate control panel’s 

Programming Guide

.

D

Digiplex and Digiplex EVO

Z8: Input terminal Z8 can be used as an anti-tamper switch input. Enable section [001] option [1]

MG/SP Serie

s

Z1: Input terminal Z1 can be used as an anti-tamper switch input. Enable section [706] option [4] for panel+1, 

option [5] for panel+9 and option [6] for panel+17

MG5000

(2 on-board zones)

MG5050

(5 on-board zones)

SP4000

(4 on-board zones)

SP5500

(5 on-board zones)

SP6000

(8 on-board zones)

SP65

(9 on-board zones)

SP7000

(16 on-board zones)

No/

ATZ 

With/

ATZ

No/

 

ATZ

With/

ATZ

No/

 

ATZ

With/

ATZ 

No/

 

ATZ

With/

ATZ

No/

 

ATZ

With/

 

ATZ 

No/

 

ATZ

With/

 

ATZ 

No/

 

ATZ 

With/

 

ATZ 

zones/

zones/

zones/

zones/

zones/

zones/

zones/z

A / Panel+1*

3-10

5-12

6-13

11-18

5-12

9-16

6-13

11-18

9-16

17-24

10-17

19-26

17-24

-

B / Panel+9*

11-18

13-20

14-21

19-26

13-20

17-24

14-21

19-26

17-24

25-32

18-25

27-32

25-32

-

C / Panel+17*

19-26

21-28

22-29

27-32

21-28

25-32

22-29

27-32

25-32

-

26-32

-

-

-

*Press “Disable Locate” for  3 seconds to change jumper setting 

Programming Method

1. Hold 

[0]

 key+ 

[

INSTALLER

 

CODE

]

2. Enter section 

[953]

 (DGP-848) 

[4003]

 (EVO)

3. Enter module’s 8-digit 

[

SERIAL

 

NUMBER

]

4. Enter 

[

SECTION

and turn desired option ON/OFF or enter the required data

Sections

[001]

Options

[1]

 Tamper Recognition

OFF†

 = Disabled

   

ON

 = Enabled (Z8)

[2]

 PGM Deactivation 

OFF† 

= Deact. Event  

ON 

= PGM timer 

[3]

 PGM Normal State

OFF†

 = N.O.

   

ON

 = N.C. 

[4] 

PGM Base time

OFF† 

= 1 sec.

   

ON 

= 1 min. 

[002]-[016]

Even Numbered

Input Speed (Base Time Selection)

(Default = all inputs @ 600ms)

Even numbered sections represent inputs terminals Z1 to Z8. Using [

q

] and [

p

] keys. Select a Base Time value from 000 to 002. Press [

ENTER

].

000= Input Speed is X by 15 milliseconds. 

001= Input Speed is X by 1 second.

002= Input Speed is X by 1 minute.

8-Zone Expansion Modules

ZX8

V6.0

Figure 1: ZX8 Connections

         PARADOX.COM

     Printed in Canada- 06/14

ZX8-EI04