The 8-zone Expansion Module (ZX8) is an interface between the control panels and any hardwired detection devices. The ZX8 connects to the control panel's combus
to provide eight additional hardwired inputs and one 50mA on-board PGM output.
Specifications
Installation
Connect the module as shown in Figure 1.
Table 1: Illustration
Table 2: Jumper Setting
Table 3: Options
Input voltage:
Typically 12 to 16 Vdc
No. of zones:
8 standard zone inputs
Current cons.:
28mA
Oper. temperature:
-20ºC to 50ºC (-4ºF to 122ºF)*
Max.# of ZX8:
max.3: MG/SP Series
Compatibility:
Any Digiplex or Digiplex EVO series control panel
Any SP Series control panel (V2.0 or higher)
MG5000/MG5050 control panels (V2.0 or higher)
WinLoad Software V2.03 or higher
NOTE: For 1728/1738 compatibility, refer to the ZX8SP instruc-
tions.
No. of outputs:
One 50mA PGM
No. of inputs:
8 inputs
A DiDigiplex EVO
A “Locate” request coming from the control panel can be disabled by pressing the “Disable Locate”.
MG/SP Series
Press the “Disable Locate” for 3 seconds. Fast flash of the green LED occurs. Jumper settings can be changed.
B Green “LOC” LED
Digiplex and Digiplex EVO
Remains Illuminated during power up
Flashes fast to indicate it is receiving a “Locate” request from the control panel.
To disable a “Locate” request, press the “Disable Locate” switch.
SP Series and MG505
0
Flashes fast to indicate a change in jumper setting.
Red “WDG” LED
All panels flashes to indicate proper operation
If both “LOC” and the “WDG” LED are flashing alternately, the module is experiencing a communication failure with the control panel.
C
Connect the detection devices to the ZX8 input terminals exactly as shown in the appropriate control panel’s
Programming Guide
.
D
Digiplex and Digiplex EVO
Z8: Input terminal Z8 can be used as an anti-tamper switch input. Enable section [001] option [1]
MG/SP Serie
s
Z1: Input terminal Z1 can be used as an anti-tamper switch input. Enable section [706] option [4] for panel+1,
option [5] for panel+9 and option [6] for panel+17
MG5000
(2 on-board zones)
MG5050
(5 on-board zones)
SP4000
(4 on-board zones)
SP5500
(5 on-board zones)
SP6000
(8 on-board zones)
SP65
(9 on-board zones)
SP7000
(16 on-board zones)
No/
ATZ
With/
ATZ
No/
ATZ
With/
ATZ
No/
ATZ
With/
ATZ
No/
ATZ
With/
ATZ
No/
ATZ
With/
ATZ
No/
ATZ
With/
ATZ
No/
ATZ
With/
ATZ
zones/
zones/
zones/
zones/
zones/
zones/
zones/z
A / Panel+1*
3-10
5-12
6-13
11-18
5-12
9-16
6-13
11-18
9-16
17-24
10-17
19-26
17-24
-
B / Panel+9*
11-18
13-20
14-21
19-26
13-20
17-24
14-21
19-26
17-24
25-32
18-25
27-32
25-32
-
C / Panel+17*
19-26
21-28
22-29
27-32
21-28
25-32
22-29
27-32
25-32
-
26-32
-
-
-
*Press “Disable Locate” for 3 seconds to change jumper setting
Programming Method
1. Hold
[0]
key+
[
INSTALLER
CODE
]
2. Enter section
[953]
(DGP-848)
[4003]
(EVO)
3. Enter module’s 8-digit
[
SERIAL
NUMBER
]
4. Enter
[
SECTION
]
and turn desired option ON/OFF or enter the required data
Sections
[001]
Options
[1]
Tamper Recognition
OFF†
= Disabled
ON
= Enabled (Z8)
[2]
PGM Deactivation
OFF†
= Deact. Event
ON
= PGM timer
[3]
PGM Normal State
OFF†
= N.O.
ON
= N.C.
[4]
PGM Base time
OFF†
= 1 sec.
ON
= 1 min.
[002]-[016]
Even Numbered
Input Speed (Base Time Selection)
(Default = all inputs @ 600ms)
Even numbered sections represent inputs terminals Z1 to Z8. Using [
q
] and [
p
] keys. Select a Base Time value from 000 to 002. Press [
ENTER
].
000= Input Speed is X by 15 milliseconds.
001= Input Speed is X by 1 second.
002= Input Speed is X by 1 minute.
8-Zone Expansion Modules
ZX8
V6.0
Figure 1: ZX8 Connections