keypad will emit a Rejection Beep. When you have correctly armed the system, the appropriate
ARM
indication will turn on and the
Exit Delay will be initiated. Please note that Regular Arming can also be activated through Auto-Arming, Keyswitch Arming or
One-Touch Arming.
13.5 STAY ARMING
This method allows users to remain in the protected area while partially arming the system. For example, when going to sleep at
night, entry/exit points like doors and windows can be armed while other zones like motion detectors remain deactivated. Please
note that Fire Zones cannot be bypassed.
If you make a mistake, the keypad will emit a Rejection Beep. When you have correctly Stay Armed the system, the appropriate
ARM
or
STAY
indication appears and the Exit Delay is initiated. Stay Arming can also be activated using Auto-Arming, Keyswitch
Arming or One-Touch Arming. The User Code must have the Stay Arming Option enabled.
13.6 INSTANT ARMING
After Stay Arming the system and during its Exit Delay, press and hold the [
STAY
] key for 3 seconds. You should hear a
Confirmation Beep. This will switch all armed zones to Instant zones.
If you have access to both partitions:
To Instant Arm one partition, press [
STAY
] + [
ACCESS
CODE
] + Select Par [
CLEAR
] + press & hold [
STAY
]
To Instant Arm both partitions, press [
STAY
] + [
ACCESS
CODE
] + [1] + [2] + press & hold [
STAY
]
13.7 FORCE ARMING
(NOT TO BE USED WITH UL INSTALLATIONS)
Force Arming allows users to rapidly arm the system, without having to wait for all zones in the system to be closed. Force
Arming is commonly used when a motion detector is protecting the area occupied by a keypad. Therefore, when arming the
system, if the motion detector is set as a Force Zone, the control panel will ignore the zone and allow users to arm the system
even if the zone is open. Any open Force Zones at the time of arming will be considered deactivated by the control panel. If
during this period a deactivated zone is closed, the control panel will revert that zone to active status, hence, will generate an
alarm if breached.
If you make a mistake, the keypad will emit a Rejection Beep. When correctly Force Armed, the appropriate arm indication
appears and the Exit Delay will initiate. Please note that Force Arming can also be activated using One-Touch Force Arming.
Also, note that the User Access Code must have the Force Arming Option enabled.
13.8 MANUAL BYPASS PROGRAMMING
Manual Bypass Programming allows users to program the alarm system to ignore (deactivate) specified zones the next time the
system is armed. The Access Code must have the Bypass Programming Option enabled. Please note that Fire Zones cannot be
bypassed. Manual Bypass Programming can also be activated using One-Touch Bypass Programming.
How Do I Regular Arm?
1)
Green “
READY
” indicator must be illuminated. Unless the system is partitioned, in which case all zones in the desired parti-
tion must be closed.
2)
Key in a valid [
ACCESS
CODE
]*.
*IF YOU HAVE ACCESS TO BOTH PARTITIONS:
Press the key corresponding to the partition you wish to arm. To arm both partitions, press the [1] key then after the
Confirmation Beep press the [2] key.
How Do I Stay Arm?
1)
All zones in the desired partition (except Stay Zones) must be closed.
2)
Press the [
STAY
] key.
3)
Key in a valid [
ACCESS
CODE
]*.
*IF YOU HAVE ACCESS TO BOTH PARTITIONS:
Press the key corresponding to the partition you wish to Stay Arm. To Stay Arm both partitions, press the [1] key then after the
Confirmation Beep press the [2] key.
How Do I Force Arm?
1)
All zones in the desired partition (except Force Zones) must be closed.
2)
Press the [
FORCE
] key.
3)
Key in a valid [
ACCESS
CODE
]*.
*IF YOU HAVE ACCESS TO BOTH PARTITIONS:
Press the key corresponding to the partition you wish to Force Arm. To arm both partitions, press the [1] key then after the
Confirmation Beep press the [2] key.