SP+ Series Programming Guide
13
Zone Definitions
NOTE:
If a device is assigned to a zone which is already programmed, a wireless zone will overwrite a keypad/hardwire zone and a keypad zone will overwrite a
hardwire zone.
To define zones on your SP+ control panel:
1.
Press
ENTER
, and then enter your installer code (maintenance code may also be used). The
ARM
and
STAY
functions will flash.
2.
Enter the three-digit zone number you wish to program (e.g.,
001
to
032
). The
ARM
and
STAY
functions will remain illuminated.
3.
Enter a two-digit zone definition, by referring to table 4.
4.
Assign a partition, by referring to table 5. By default, all zones are assigned to partition 1.
5.
Select or deselect zone options, using buttons
1
to
8
6.
Press
ENTER
to save and proceed to the next zone.
7.
Repeat steps 3 to 6 for all remaining zones.
Table 4: Zone definitions for SP+ Series panels
Input Value
Description
Arming Type
Stay Arm
Sleep Arm
Fully Arm
00
Disabled (default)
-
-
-
01
Entry delay 1
Entry delay 1
Entry delay 1
Entry delay 1
02
Entry delay 2
Entry delay 2
Entry delay 2
Entry delay 2
03
Entry delay 1 (Full Arm)
Not armed
Not armed
Entry delay 1
04
Entry delay 2 (Full Arm)
Not armed
Not armed
Entry delay 2
05
Follow
Follow*
Follow*
Follow
06
Follow (sleep/full arm)
Not armed
Follow*
Follow
07
Follow (full arm)
Not armed
Not armed
Follow
08
Instant
Instant*
Instant*
Instant
09
Instant (sleep/full arm)
Not armed
Instant*
Instant
10
Instant (full arm)
Not armed
Not armed
Instant
11
Instant fire†
-
-
-
12
Delayed fire†
-
-
-
13
Instant fire silent†
-
-
-
14
Delayed fire silent†
-
-
-
15
24 hr. buzzer
-
-
-
16
24 hr. burglary
-
-
-
17
24 hr. hold-up
-
-
-
18
24 hr. gas
-
-
-
19
24 hr. heat
-
-
-
20
24 hr. water
-
-
-
21
24 hr. freeze
-
-
-
22
24 hr. panic‡
-
-
-
23
Follow no pre-alarm
-
-
-
24
Instant no pre-alarm
-
-
-
25
Keyswitch maintain**
-
-
-
26
Keyswitch momentary**
-
-
-
33
Instant no pre-alarm (stay/sleep)
Instant
Instant
Not armed
34
Instant no pre-alarm (sleep)
Not armed
Instant
Not armed
35
Entry delay 1 (stay/full)/instant
Entry delay 1
Instant
Entry delay 1
36
Entry delay 1 (full arm)/instant
Instant
Instant
Entry delay 1
* Flex-instant: zone will follow the delay at section
[720]
(default is 15 seconds/0 = instant zone).
** On-board, hardwire, control panel zones only.
† ZX8/ZX82 inputs do not support fire zones. For two-wire smoke installations these definitions apply to
zone 1 input only. Section
[706]
, option 3, must be enabled. For four-wire smoke installations, use any panel,
on-board zone input.
‡ This alarm will follow the panic 1 option (section
[702]
, option 1).
Table 5: Partition assignment for SP+ Series panels
Input Value
Description
1
Assign to partition 1
2
Assign to partition 2
3
Assign to both partitions
NOTE:
When using the K636 keypad, only
partition 1 is available.
Table 6: Zone options for SP+ Series panels
Input
Value
Description
1
Auto zone shutdown
2
Bypassable zone
3
RF zone supervision
6
Intellizone
7
Delay alarm transmission
8
Force zone
Input Value
Zone Alarm Type
4
5
OFF
OFF
Audible alarm
OFF
ON
Pulsed alarm
ON
OFF
Silent alarm
ON
ON
Report only
NOTE:
For additional zone options, see
Table 7: Keyswitch options for SP+ Series panels
Input
Value
Description
1
-
2
-
3
-
4
OFF = Disarm
; ON = Disarm only
if Stay/Sleep armed
5
Arm only
6
Stay arming*
7
Sleep arming*
8
-
* Select only one. If all are OFF, keyswitch will
regular arm.
Содержание SP5500+
Страница 1: ...SP5500 SP6000 SP7000 Programming Guide 4 to 32 Zone Expandable Security Systems ...
Страница 65: ...SP Series Programming Guide 65 Notes ...
Страница 66: ...66 SP Series Programming Guide ...
Страница 67: ......