NVR780-EI04 Printed in Canada 02/2012

NVR780 

Wireless Digital Outdoor Dual Side-View Detector with 4x Dual Sensors

Installation Manual V2.5

Power-up Sequence 

If the module is set in Single Mode:
• Both left and right LEDs blink simultaneously 4 times
• Buzzer activates (on/off beep: one tone)

Detector Settings

IMPORTANT: 

When changing DIP switch settings, the unit must be powered. To save changes, trigger the box tamper or close the cover.

 

DIP Switch#

Functionality

Min. and Max. Detection Coverage

DIP Switch 1

LED

Enable (ON) or disable (OFF) the LED, (

default = ON

)

The following is the minimum and maximum detection 
coverage when the vertical beam adjustment is set at 0°.

DIP Switch 2

Buzzer

Enable (ON) or disable (OFF) the buzzer, (

default = OFF

)

Minimum 
Coverage

Maximum 
Coverage

DIP Switch 3

Sensitivity 

(see table at right)

ON= 100% (High), OFF= 75% (Normal), (

default =OFF

)

75% Sensitivity
Level

0.4m (1.3 ft.)

11m (36 ft.)

DIP Switch 4

Zone Mode: Single/Dual

ON= Single Mode, OFF= Dual Mode, (

default =ON

)

100% Sensitivity
Level

0.1m (0.3 ft.)

23m (75.4 ft.)

Introduction

The wireless NVR780

 incorporates two independent, side-by -side passive infrared detectors into a single housing. Covering up to 24 meters (12m 

for each side), and configurable to report as a single unit (2 sides of the unit report to a single zone output) or dual units (each side reports to a 
separate zone output), the NVR780 provides flexible and accurate boundary protection.

Installation

To install the NVR780:
1) Select the detector’s location. Remove the front cover screws holding the cover into place; open the cover.

2) Mount the unit on a flat, even, clean surface. Mount the back plate to the wall by securing the included 1.5” screws (4x) in each of the 

dedicated mounting holes. Secure the 2” screw in the dedicated wall tamper hole. 

IMPORTANT:

 Do not overtighten the tamper screw, it may 

lead to water infiltration of the unit. Also, the unit must be installed at least 40 cm (15.7 in) away from the desired protected area (door, 
window, etc.) when its sensitivity is set at 75% and 10 cm (3.9 in) when set at 100%. See Detector Settings below to set the sensitivity.

Enrollment

To enroll the NVR780 to the system, please refer to your respective panel’s/receiver’s Programming Guide. If you are assigning the zones of the 
NVR780 via the anti-tamper switch, press once (under 1 sec.) to assign the first zone, and twice (under 1 sec. each) to assign the second. 

Reporting (Zone Mode)

The NVR780 is

 

configurable to report as a single unit (

Single Mode

: two sides of the unit report as a single zone) or dual units (

Dual Mode

: each 

side reports as two separate zones). In 

Single Mode

, report has only one S/N. In 

Dual Mode

, report has two separate S/N, one for each side. Zone 

Mode is configured via DIP switches. See 

Detector Settings

 below to set the Zone Mode to either Single or Dual. 

NOTE: In Dual Mode, the ‘Cover 

Tamper’ is reported to zone 1, and the ‘Wall Tamper’ is reported to zone 2.

Walk-Testing

To put the detector into Walk-test Mode, open and close the cover, or unplug and then plug in the battery pack. Walk-test Mode lasts five minutes. 

IMPORTANT

:

 

If the cover remains open, the unit will not be operational. When in Walk-test Mode, the unit will not go into Energy Save Mode.

If the module is set in Dual Mode:
• Both left and right LEDs blink alternately 4 times
• Buzzer activates (two tones, continuous)

Energy Save Mode

The NVR780 enters into Energy Save Mode after two detections within 5 minutes. In Energy Save Mode, both the LED 
indication and buzzer indication are shorter than during normal operation. After 3 minutes, the module returns to transmission mode.

Battery Replacement

Replace the pack in its original orientation; the batteries must be facing up (towards PCB enclosure), and the connector must be on the left side.

Alarm

If the module is set in Single Mode:

LED

: red LED indication only on the relevant side(s) for 2 sec. 

Buzzer

: activates (same tone for each side)

If the module is set in Dual Mode:

LED

: red LED indication only on the relevant side(s) for 2 sec.

Buzzer

: activates, each side has its own tone. If there is an alarm 

on both sides, there is a separate, third tone. 

Firmware Upgrade via Built-in Serial Port

For upgrade instructions, refer to the Firmware Upgrade Instructions document which is available at paradox.com > Software > WinLoad.