Paradox NV37M Скачать руководство пользователя страница 1

NV37M-EI00  07/2021

PARADOX.COM

NV37M

Installation Manual V1.0

Outdoor/Indoor Window and Sliding Door 

Dual Detector with Anti-Masking and 

Pet Immunity

General Description

Thank you for choosing the NV37M for your professional protection 

needs. The NV37M wired version will provide you the most advanced 

window and sliding door protection either in Pet Immune or Sharp 

mode. If you have any comments, please write to us at Paradox.com/

products/feedback. 

Recommended Installations (please read)

Outdoor installation permits placements within frames of sliding 

windows or doors and presumes protection from raindrops. This 

ensures best catch performance, anti-masking ability, and pet alarm 

immunity.
Other installations are possible but in outdoor conditions, pet immunity 

can decrease. Moreover, space near the detector must be clear from 

obstacles from a distance of 30 to 40 cm (11.8 to 15.7 in.) within its 

pattern. 

Installing the NV37M

1. Remove the NV37M front cover - open the Captive screw.

2. Remove the Main Unit - open the two snap-lock mechanisms on 

each side of the back cover attaching the Main Unit to the back 

cover, then remove the Main Unit.

3. Pull the wires from the control panel through the knockout holes 

and mount the back cover onto the window frame or wall using 

screws.

Note: PLEASE KEEP AT LEAST 4 cm / 1.5 in. clearance from 

window/shutter.

 

4. Attach the Main Unit to the back cover - ensure the locks snap 

closed. 

5. Connect the wires to the terminal blocks according to the following 

wiring assignment.

Table 1:  Wiring Assignment

6. Set the following Detector settings according to requirements.

 Figure 4 – Detector Settings

The following table displays the 

Dip Switch

 settings.

Table 2: Dip Switch Settings

7. Replace the front cover and close the Captive screw.

Note: Do not obscure the detector's field of view.

Testing the NV37M

Perform a 

Walk-Test

 to test successful installation: 

1.

Walk slowly across the far end of the detection range. 

2.

Ensure detection.

Walk test mode lasts 5 minutes after the tamper screw is closed.

 Figure 1 – Front Cover

 Figure 2 – Main 

Unit

 Figure 3 – Back Plate

Front 
cover

Captive screw

Mounting

screw 
Tamper 

knockout 
hole 

Knockout

holes

Tamper 

screw

An optional mounting bracket for the NV37M is available for ordering, 
part number: SB35.

4 cm / 

1.5 in. 

Terminal Connector

Recommended Wiring Assignment

1

12V+

2

Minus (-)

3

Fault indication

4

Tamper* indication

5

Common (Fault & Tamper)

6

Alarm indication

7

Common (Alarm)

* Tamper must be enabled on SP panels.

Dip Switch 

Number

Function

Mode Description

1

LED

ON

:  LED on (default)

OFF

: LED off

2

PET Immunity/

SHARP Mode

ON

:  PET Immunity mode (default)

OFF

: SHARP mode

3

Anti-mask

ON

:  On (default)

OFF

: Off

4

Anti-mask 
Sensitivity

ON

:  High (default)

OFF

: Low

Dip 
Switch

Sensitivity Trimmer

LED flashes green 1-3 
times according to the 
selected level