52
Programming Guide
Usability Sections
The sections described in the ensuing segment are used to clear, reset, and display various settings and features on your control panel.
Description of Sections [950], [955], and [960]
Description of Section [965]
NOTE:
When resetting any option in section
[965]
, ensure that all other options are deselected. Press
ENTER
to reset the respective set of labels to their default
values, before exiting the section.
Worksheet 50: IP Receiver 1 Configuration
Section Data
Description
Default
[929]
__/__/__ . __/__/__ . __/__/__ . __/__/__
WAN1 IP address (e.g.,
100.100.100.100
); for one or
two-digit numbers, add
0
s before the first digit
-
[930]
__/__/__/__/__
WAN1 IP port
10000
[931]
__/__/__ . __/__/__ . __/__/__ . __/__/__
WAN2 IP address
-
[932]
__/__/__/__/__
WAN2 IP port
10000
[933]
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
IP password
123456
[934]
__/__
IP profile (e.g.,
01
)
-
[935]
To view status or to register, press
ARM
IP receiver status
-
Worksheet 51: IP Receiver 2 Configuration
Section Data
Description
Default
[936]
__/__/__ . __/__/__ . __/__/__ . __/__/__
WAN1 IP address (e.g.,
100.100.100.100
)
-
[937]
__/__/__/__/__
WAN1 IP port
10000
[938]
__/__/__ . __/__/__ . __/__/__ . __/__/__
WAN2 IP address
-
[939]
__/__/__/__/__
WAN2 IP port
10000
[940]
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
IP password
123456
[941]
__/__
IP profile (e.g.,
01
)
-
[942]
To view status or to register, press
ARM
IP receiver status
-
Worksheet 52: IP Receiver Backup Configuration
Section Data
Description
Default
[943]
__/__/__ . __/__/__ . __/__/__ . __/__/__
WAN1 IP address (e.g.,
100.100.100.100
)
-
[944]
__/__/__/__/__
WAN1 IP port
10000
[945]
__/__/__ . __/__/__ . __/__/__ . __/__/__
WAN2 IP address
-
[946]
__/__/__/__/__
WAN2 IP port
10000
[947]
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
IP password
123456
[948]
__/__
IP profile (e.g.,
01
)
-
[949]
To view status or to register, press
ARM
IP receiver status
-
Table 44: Description of sections [950], [955], and [960]
Section Description
[950]
Resets all programmable sections to their respective factory-set, default values. Once accessed, press
ENTER
to reset.
[951]
Sets panel for EN 50131 compliancy. To set the panel, enter section
[951]
and press
ENTER
.
[955]
Clears bus module troubles. Once cleared, remove disconnected module from the bus.
[960]
Displays the wireless transmitter serial number. Once accessed, press any button on the assigned remote control, or
press the tamper switch of the download memory key. Press
ENTER
to view the next digit.
Table 45: Description of section [965] (reset labels)
Option
Description
OFF
ON
Se
c
ti
o
n
[965]
1
Reset zone labels
Disabled
Enabled
2
Reset user labels
Disabled
Enabled
3
Reset partition labels
Disabled
Enabled
4
Reset PGM labels
Disabled
Enabled
5
Reset bus module labels
Disabled
Enabled
6
Reset wireless repeater and siren labels
Disabled
Enabled
7
Reset wireless keypad, repeater, and siren labels
Disabled
Enabled
= Default