26
Reference & Installation Manual
When the Magellan system is in entry delay, the console will
send a message to the MG-2WPGM telling it that it is in entry
delay. During the entry delay, the MG-2WPGM will check for
communication with the Magellan console every 10 seconds and
if there is no response from the console, the relay will activate.
To enable the backup reporting option:
1. Press [
MENU
] + [4] + [
INSTALLER
CODE
] + [7].
2. Using the [
NEXT
]
key, scroll to the [
CONSOLE
SUPERV
?
]
option.
3. Press [
OK
]
.
Panic Alarms
Section [091]: Options [1], [2] and [3]
Option [1] OFF = Panic 1 (Non-Medical Emergency Panic)
disabled (default)
Option [1] ON =
Panic 1 (Non-Medical Emergency Panic)
enabled
Option [2] OFF = Panic 2 (Auxiliary Panic) disabled (default)
Option [2] ON =
Panic 2 (Auxiliary Panic) enabled
Option [3] OFF = Panic 3 (Fire Panic) disabled (default)
Option [3] ON =
Panic 3 (Fire Panic) enabled
Enable section [091] options [1], [2] and [3] to enable the
system’s three panic alarms. Each panic alarm is activated by
pressing two keys simultaneously and holding them down for 2
seconds. See Table 6 on page 26 for the appropriate panic alarm
keys. Whether these panic alarms will generate a silent or
audible alarm is determined by section [091] options [4] to [6]
(see Panic Alarm Types on page 26).
Table 6: Panic Alarm Keys
Remote controls can also be programmed to generate panic
alarms. See Programming the Remote Control’s Buttons on
page 20 for more information on programming remote controls
to generate panic alarms.
Panic Alarm Types
Section [091]: Options [4], [5] and [6]
Option [4] OFF = Panic 1 (Non-Medical Emergency Panic) is
silent (default)
Option [4] ON =
Panic 1 (Non-Medical Emergency Panic) is
audible
Option [5] OFF = Panic 2 (Auxiliary Panic) is silent (default)
Option [5] ON =
Panic 2 (Auxiliary Panic) is audible
Option [6] OFF = Panic 3 (Fire Panic) is silent (default)
Option [6] ON =
Panic 3 (Fire Panic) is pulsed
Options [4] to [6] represent the alarm types of panic alarms 1 to 3
respectively.
Silent Alarm: The Magellan console will emit a confirmation beep
and transmit the appropriate Panic report code (if programmed in
section [139]). The console will not enable its speaker or the
system siren.
Audible Alarm: Same as the silent alarm except that the console
will enable its speaker and system siren until a user cancels the
alarm (disarms) with a valid Access code or when the Bell Cut-off
timer elapses (if enabled; see Bell Cut-off Timer on page 24).
Pulsed Alarm (Fire Panic only): Same as the audible alarm
except that the siren will be pulsed as shown in Figure 20 on
page 16. Refer to Standard 24Hr. Fire Zones on page 16 for
more information on a pulsed siren output.
Remote Panic Disarm Lock Delay
Section [078]: 001 to 255 seconds; 000 = Disabled; Default = 20
seconds
When a panic alarm is generated through the use of a remote
control, the system cannot be disarmed by remote control during
the Remote Panic Disarm Lock Delay.
Enter the desired 3-digit delay value into section [078] to
program the Remote Panic Disarm Lock Delay.
Keys to press
Panic Alarm Type
[1] and [3]
Panic 1 (Non-Medical Emergency Panic)
[4] and [6]
Panic 2 (Auxiliary Panic)
[7] and [9]
Panic 3 (Fire Panic)
Содержание MG-6130
Страница 2: ......