Paradox Magellan Systems
25
Table 5: Tamper Recognition Options
Tamper Bypass Options
Section [094]: Option [5]
Option [5] OFF = Ignore any tampers detected on a bypassed
zone (default)
Option [5] ON = Generate tamper if detected on a bypassed
zone
•
When option [5] is ON, the Tamper Recognition feature (see
page 24) will ignore the zone’s bypass definition. This
means the console will generate an incident as per the set
Tamper Recognition option if a tamper occurs on a
bypassed zone.
•
When option [5] is OFF, the Tamper Recognition feature
(see page 24) will follow the zone's bypass definition. This
means the console will ignore any tampers that occur on a
bypassed zone.
Wireless PGM Supervision Options
Section [294]: Options [1] to [4]; Wireless PGMs 1 to 4; Default:
All ON
If enabled, Magellan can wait for each of its assigned MG-
2WPGM transmitters to send a status signal within a specified
time (see Check-in Supervision Time on page 24) to confirm their
presence and functionality. If a device has not sent a signal
within the specified time period or Magellan tries to communicate
with the device without success, Magellan can generate a
trouble, an alarm and/or transmit a report code to the monitoring
station as defined by the Wireless Transmitter Supervision
Options (see page 24). Section [194] determines which wireless
PGMs will be supervised and which will not. Enable the option
pertaining to the MG-2WPGM you wish Magellan to supervise.
Wireless Keypad Supervision Options
Section [295]: Options [1] to [4]; Wireless keypads 1 to 4;
Default: All ON
If enabled, Magellan can wait for each of its assigned wireless
keypads to send a status signal within a specified time (see
Check-in Supervision Time on page 24) to confirm their
presence and functionality. If a device has not sent a signal
within the specified time period or Magellan tries to communicate
with the device without success, Magellan can generate a
trouble, an alarm and/or transmit a report code to the monitoring
station as defined by the Wireless Transmitter Supervision
Options (see page 24). Section [295] determines which wireless
PGMs will be supervised and which will not. Enable the option
pertaining to the wireless keypad you wish Magellan to
supervise.
Wireless Repeater Supervision Options
Section [296]: Options [1] to [2]; Wireless repeaters 1 to 2;
Default: All ON
If enabled, Magellan can wait for each of its assigned wireless
repeaters to send a status signal within a specified time (see
Check-in Supervision Time on page 24) to confirm their
presence and functionality. If a device has not sent a signal
within the specified time period or Magellan tries to communicate
with the device without success, Magellan can generate a
trouble, an alarm and/or transmit a report code to the monitoring
station as defined by the Wireless Transmitter Supervision
Options (see page 24). Section [296] determines which wireless
repeaters will be supervised and which will not. Enable the
option pertaining to the wireless repeater you wish Magellan to
supervise.
Wireless PGM Console Supervision Options
(Follow Alarm/Follow Bell)
Section [297]: Options [1] to [4]; Wireless PGMs 1 to 4; Default:
All OFF
This feature allows you to further program any wireless PGM that
is set to follow an alarm or bell by allowing you to also program
the wireless PGM to activate following an absence of successful
communication with the Magellan console. If enabled, Magellan
can send a status request to each of its assigned MG-2WPGM
transmitters to confirm their presence and functionality. If a
device has not received a status request by the Magellan
console within a specified time period, the MG-2WPGM will
activate. Section [195] determines which wireless PGMs that are
set to follow an alarm/bell will supervise the Magellan console. If
a wireless PGM has already been programmed for console
supervision, this option will be ignored.
Backup Alarm Reporting Option
This feature provides you with the option of supervising the
communication between the Magellan console and the MG-
2WPGM. If enabled, the MG-2WPGM will periodically check for
communication with the Magellan console. If there is no
response from the console, the relay will activate.
Options
Description
[3]
[4]
OFF
OFF
Tamper Recognition disabled (default)
OFF
ON
Trouble only
System armed or disarmed: If a tamper wiring failure
occurs on a zone, the console will generate a trouble
and send a report to the monitoring station (if
programmed).
ON
OFF
Audible alarm when armed
System armed: If a tamper failure occurs on a zone,
the console will follow the zone's Alarm Types setting
(see page 17).
System disarmed: If a tamper failure occurs on a
zone, the console will generate a trouble and send a
report to the monitoring station (if programmed).
ON
ON
Audible alarm
System armed: If a tamper failure occurs on a zone,
the console will follow the zone's Alarm Types setting
(see page 17).
System disarmed: It functions the same as Trouble
Only setting, except it will also generate an audible
alarm.