background image

What’s New with Version 1.5

• Added support for the REM3 on EVO panels (requires EVO V2.1 or 

higher)

• Added support for 4 wireless sirens (SR150) on Spectra SP panels 

(requires Spectra SP V4.0 or higher)

Introduction

The RTX3 is a 2-Way Wireless Expansion Module for use with any Digiplex 
EVO, Spectra SP, and Esprit series control panel. It is also compatible with 
the DGP-NE96 and DGP-848 control panels.

Before Programming

1.

Connect the RTX3 according to the installation guide.

2.

Write down the serial number of all wireless modules to be used with 
the RTX3. If this installation replaces another RTX3, make sure the 
programming can be transferred.

3.

Make sure every wireless module works properly and that you have 
the latest version of the firmware for the RTX3 and panels.

System Reset

Press and hold the Programming button for 5 seconds, the BUS RX LED 
will flash. Release the button and press it again while the LED flashes to 
reset the module to its default values. The system reset feature only 
functions during the first 30 seconds after the RTX3 is powered up.

Compatibility Chart

EVO

Spectra SP Esprit

Stand Alone

Zones

32

32

-

32

# of Remotes

32/96/999

32

32

32

Remote Type

REM1
REM2
REM3

REM1
REM2
REM3

REM1

REM1

Wireless PGMs

8

16

-

-

Wireless Keypads

-

8

-

-

2-Way Remote

3

3

-

-

Wireless Siren

-

4

-

-

Wireless Repeater

-

2

-

-

PX8 Output Module

-

-

-

4

PARADOX.COM

Printed in Canada 02/2009

Wireless Expansion Module

RTX3 V1.5 

Instructions

Spectra SP Series Programming

When connected to a Spectra SP series panel, the RTX3 settings are programmed into the panel. Refer to the 
panel’s Programming Guide. Requires version 2.0 or higher of the K32 or K10V/H keypads. You can only connect 
one RTX3 to a Spectra SP Series panel.

Digiplex EVO Programming

To enter programming mode with a Digiplex EVO panel, press and hold the 

[0]

 button. Enter the installer code and go to 

section 

[4003]

. Enter the RTX3’s 8-digit serial number. Enter the section number you wish to program.

After Programming with EVO

Program the zones, PGMs, and remotes into the EVO panel. Look at EVO section 

[3034]

 and RTX3 section 

[001]

 options 

[2] 

and

 [3]

 for wireless transmitter supervision options. 

WARNING: When used without a K641 or K641R keypad, enable EVO option [1] in section [3029].

* The new visual and auditory feedback includes the following system statuses: stay armed, instant armed and exit delay. Other statuses’ 
feedback have not changed. Note that for REM2 versions 1.04 or older, stay arm, instant arm and exit delay statuses are not supported, 
and a rejection beep will be heard when the system is in these statuses.

Table 2: EVO PGM Option Programming

Table 1: Digiplex EVO Programming

[001]

RTX3 Options

Option [1]: Low battery supervision (default: ON) 

- For RTX3 version 1.5 and higher, this option  

 is always ON.

Option [2]: Check-in supervision (default: OFF)
Option [3]: Check-in supervision time interval

OFF

=

24 hours (default)

ON

=

80 minutes

Option [4]:  RF Jamming supervision (default: ON)
Option [5]:  On-board module tamper supervision (default: OFF)
Option [6]:  PGM1 Initial State

OFF

=

Normally Open (default)

ON =

Normally 

Closed

Option [7]:  PGM2 Initial State

OFF

=

Normally Open (default)

ON =

Normally 

Closed

Option [8]:  Ignore transmitter tamper signal

OFF

=

RTX3 ignores tamper signal (default)

ON 

=

RTX3 reports tamper signal

[002]

Remote Control Options

Option [1]: REM2 Visual and auditory feedback compatibility options*

OFF

=

Old visual and auditory feedback. (Supported by REM2 V2.00 or higher)

ON

=

New visual and auditory feedback. (REM2 V2.01 or higher with K641 /
K641R keypads.) (Default)

[030]

View Transmitter, Remote and PGM Serial Numbers

To view a transmitter’s 6-digit serial number, press and hold the transmitter’s anti-tamper switch.

[101] to [132]

Assign Wireless Transmitters

[101] = Zone Input 1; [132] = Zone Input 32
Enter 6-digit serial number or press and release the transmitter’s tamper switch.
To delete an assigned transmitter, enter 000000 as a serial number.

See text

Remote Controls

To program REM1/REM2/REM3 remotes controls, refer to User Code and Remote Control Programming 
in the EVO Programming Guide or program remotes using WinLoad.
NOTE: If programming REM1/REM2 remotes for a system that does not include a K641/K641R keypad, 
enable EVO option [1] in section [3029] and refer to Table 3 (maximum of 32 remotes).

[601] to [632]

Transmitter Signal Strength

[601] = Zone Input 1; [632] = Zone Input 32
3 or less = weak (move transmitter); 4 to 10 = OK.

[701] to [732]

Current Battery Life

[701] = Zone Input 1; [732] = Zone Input 32
View number of weeks the batteries have been in the transmitter.

[801] to [832]

Previous Battery Life

[801] = Zone Input 1; [832] = Zone Input 32
View number of weeks the previous batteries were in the transmitter.

[671] to [678]

Two-Way PGM Signal Strength

[671] = PGM 1; [678] = PGM 8
3 or less = weak (move transmitter); 4 to 10 = OK.

[901] to [908]

Assign Two-Way PGMs

 

[901] = PGM 1; [908] = PGM 8
Enter 6-digit serial number or press and release the transmitter’s tamper switch
To delete an assigned Two-Way PGM, enter 000000 as a serial number.
If a section between [901] to [904] is empty, the RTX3 will use the on-board PGM.

[910] to [989]

PGM Programming

Program the Two-Way PGM activation event, deactivation event and PGM Delay options. Refer to 
Table 2.

[991]

View Two-Way PGM tamper trouble (PGM # in trouble will be displayed)

[992]

View Two-Way PGM supervision trouble (PGM # in trouble will be displayed)

PGM Activation*

PGM Deactivation*

PGM Delay

 Event 
Group

Feature 

Group

 Start #

End #

 Event 
Group

Feature 

Group

 Start #

End

Delay 

(000 to 

255)

Options

PGM1

[910]

[911]

[912]

[913]

[914]

[915]

[916]

[917]

[918]

[919]

PGM2

[920]

[921]

[922]

[923]

[924]

[925]

[926]

[927]

[928]

[929]

PGM3

[930]

[931]

[932]

[933]

[934]

[935]

[936]

[937]

[938]

[939]

PGM4

[940]

[941]

[942]

[943]

[944]

[945]

[946]

[947]

[948]

[949]

PGM5

[950]

[951]

[952]

[953]

[954]

[955]

[956]

[957]

[958]

[959]

PGM6

[960]

[961]

[962]

[963]

[964]

[965]

[966]

[967]

[968]

[969]

PGM7

[970]

[971]

[972]

[973]

[974]

[975]

[976]

[977]

[978]

[979]

PGM8

[980]

[981]

[982]

[983]

[984]

[985]

[986]

[987]

[988]

[989]

Default Data

000

000

000

000

000

000

000

000

005

OFF

The following options apply to sections

 [919]

,

 [929]

...

 [989]

:

Option [1]

: PGM deactivation after:

See table on right

Option [2]

: PGM base time:

ON = Minutes
OFF = Seconds (default)

Option [8]

:  Flexible PGM deactivation**:

See table on right

* For a complete list of events, 
refer to the PGM programming 
section of your Digiplex or 
Digiplex EVO control panel’s 

Programming Guide

.

** In order to use the “Flexible 
PGM deactivation” option (option 
[8]), the PGM deactivation after 
option (option [1]) must be ON.

Table 3: Programming Without a K641/K641R

[040] to [043]

View or Delete Used Remotes

[040] = remotes 1 to 8; [043] = remotes 25 to 32.
To delete a remote, press the corresponding number until it is no longer displayed in these sections.

[201] to [232] 

Assigning Remote Controls to the System

[201] = remote 01; [232] = remote 32
Enter the desired section and then press and hold a button on the remote control until you hear a 
confirmation beep.

[301] to [332]

Assign Remotes Controls to Users

Assign the remote controls to users by entering a user number (001 to 255) in the appropriate section 
(Users 001 to 255, Section [301] = remote 01, section [332] = remote 32.)

[401] to [432]

Program or Delete Remote

[401] = remote 01; [432] = remote 32

______/ ______/ ______/ ______/ ______/ ______/ ______/ ______ (default: 15000000)

  

   

  

   

   

  

   

 see 

Figure 1

  

   

  

   

   

  

   

 see 

Figure 2

[0] = Button Disabled

[8] 

= Panic 2 (Non-Medical)

[1] = Regular Arm

[9] 

= Panic 3 (Fire)

[2] = Stay Arm 

[

STAY

]

= Smoke reset

[3] = Instant Arm 

[

FORCE

]  = Utility Key 1

[4] = Force Arm

[

ARM

= Utility Key 2

[5] = Disarm 

[

DISARM

] = Utility Key 3

[6] = Stay/Instant Disarm 

[

BYP

]

= Utility Key 4

[7] = Panic 1 (Police) 

[

MEM

= Utility Key 5

[

CLEAR

] = Exit without saving 

[

ENTER

= Save data

[1]

[8]

OFF OFF Deactivation Event
OFF ON Deactivation Event

ON OFF PGM Timer
ON

ON PGM Timer or

Deactivation Event

N/A

+

N/A

N/A

N/A

+

N/A

N/A

Figure 1: REM1

Figure 2: REM2

RTX3-EI08