54
Magellan & Spectra SP • Installation Guide
Recent Closing Delay
Section
[838]
000 = Disabled, 001 to 255 seconds, Default = Disabled
If after having armed the system, an alarm is generated within the period defined by the Recent Close Delay, the control panel will attempt to transmit the Recent
Close report code programmed in section
[863]
.
Auto Test Report
Sections
[840]
000 = Disabled, 001 to 255 days, Default = Disabled
Section
[850]
: Time (HH:MM)
The control panel will transmit the Test Report report code programmed into section
[875]
after the number of days programmed into section
[840]
has elapsed at
the time programmed into section
[850]
. Use the 24-hour clock to program the time (i.e. 6:30PM = 18:30). The first Test Report will be transmitted within 24 hours
after the feature is enabled at the time programmed in
[850]
.
Example:
Section
[840]
= 005 and section
[850]
= 13:00. The first Test Report will be sent at 1 PM that day and then the report will be sent every 5 days at 1 PM.
Auto Test Report Transmission Options
Sections
[800]
Armed Report Delay
Section
[851]
000 = disabled, 001 to 255 minutes, Default = 5 min.
The Armed Report Delay determines the amount of time after an Arming event that the control panel will wait before sending a report.
Disarmed Report Delay
Section
[852]
000 = disabled, 001 to 255 minutes, Default = 60 min.
The Disarmed Report Delay determines the amount of time after an Disarming event that the control panel will wait before sending a report.
Closing Delinquency Delay
Section
[719]
000 = Disabled, 001 to 255 days, Default = Disabled
At midnight every day, the control panel will verify when the partition was last disarmed. If the partition has not been armed within the time programmed in the
Closing Delinquency Delay, the control panel will transmit a Closing Delinquency event to the monitoring station.
Example:
The Closing Delinquency Timer for partition 1 in section
[719]
is programmed for 005 days. The control panel verifies when partition 1 was last disarmed
at midnight every day. If partition 1 was not armed within the last 5 days, the panel will transmit a Closing Delinquency event to the monitoring station.
The Closing
Delinquency Event and timer apply only to partition 1
.
Power Failure Report Delay
Section
[839]
001 to 255 minutes, Default = 15 minutes
The control panel will transmit the AC Failure report code programmed in section
[865]
after the Power Failure Report Delay period has elapsed.
Report System Disarming
Section
[801]
: Arming /Disarming Options
Option
[1]
OFF= Always Report Disarming
Option
[1]
ON= Report Disarming Only After Alarm (default)
With option
[1]
OFF, the control panel will send the Disarming report codes (See “Special Disarming Report Codes” on page 49) to the monitoring station every time
the system is disarmed. With option
[1]
ON, the control panel will send the Disarming report codes to the monitoring station when the system is disarmed following
an alarm.
[3]
[4]
Auto-Test Report Transmission Options
OFF
OFF
Transmit the test report code every time the days programmed in section
[840]
have elapsed at the time pro-
grammed in section
[850]
(default).
OFF
ON
When disarmed: Transmit test report code every time the time programmed in section
[852]
has elapsed. When
armed: Transmit test report code every time the time programmed in section
[851]
has elapsed.
ON
OFF
The control panel will transmit the test report code every hour on the minute value programmed in section
[850]
(the last two digits). Note that the first two digits of section
[850]
will be ignored.
E.g. If 10:25 was programmed
into section [850], the test report code would be transmitted at the 25th minute of every hour, i.e. 11:25, 12:25, etc.
ON
ON
The test report code will be transmitted when any of the conditions of the second and third options listed above
(options
[3]
= OFF and
[4]
= ON / options
[3]
= ON and
[4]
= OFF) are met.