Paradox IPC10 Скачать руководство пользователя страница 9

IPC10 Replacement

 

If an IPC10 module may need to be replaced, the following steps should be followed: 

1. Remove the existing IPC10 from the rack it is installed on, replace it with the new IPC10 unit, and connect the IPC10 to a POE switch.

2. Configure the new IPC10 by following steps 1-6 (pages 2-6).

Note: 

The network configuration of the replacement IPC10 SHALL be the same as the IPC10 that was removed. 
The output protocol configuration of the replacement IPC10 SHALL be the same as the IPC10 that was removed 

At this point all the accounts will appear in the replacement IPC10 and reporting to the CMS will be resumed. 

Specifications

 

Compatibility

 

IP180 (Et Wi-Fi), PCS265V8 (LTE), IP150+ FW 6.0 or higher,  and Paradox panels with 
IP or cellular on-board 

Input Voltage

 

Power over Ethernet: 35-57 VDC, Class 2 device 

Account Capacity 

5,000 normal or long supervision, 3,000 for high supervision 

Supervision 

Long: 20 minutes, 10 minutes 
Normal (default): 5 minutes 
High: 90 seconds 

Supervision Message 

Offline (E551) and online (R551) despite new events 

Power Input

 

12.5W 

Operating Temperature

 

0°C to +40°C (+32°F to +104°F) 

Replacement Recovery

 

Auto recovery in case of replacement within 5 minutes 

Encryption Type

 

AES 128-bit 

Communication Protocol

 

CID via Sur-Gard MLR2-DG or Ademco 

Dimensions

 

Fits 

19” rack 1U 

48.26 x 20.3 x 4.2 cm  (19 x 8

 

x 1.65 in)

 

Warranty

 

For complete warranty information on this product, please refer to the Limited Warranty Statement found on the Web site www.paradox.com/Terms. or contact your local 
distributor. Specifications may change without prior notice. 

Patents

 

US, Canadian and international patents may apply. Paradox is a trademark or registered trademarks of Paradox Security Systems (Bahamas) Ltd. © 2023 Paradox Security 

Systems (Bahamas) Ltd. All rights reserved. www.paradox.com 

Содержание IPC10

Страница 1: ...ervision and 3 500 accounts at 90 seconds 100ms reporting cycle from panel to CMS Fully encrypted communications with ALS 128 bit certificates Fully supervised Simple and fast up time with minimal pro...

Страница 2: ...evices MQTT Green MQTT active Gateway Green Valid gateway CMS Green Connected to the CMS Amber blinking Transmitting data to the CMS User Green User connected to the IPC10 web page Location and Mounti...

Страница 3: ...sensitive Confirm password Keep the password in safe place as If you lose the password you must reset the receiver and reprogram it however all logs and events will be lost Use pin to press the reset...

Страница 4: ...llows you to configure the output protocol used by the IPC10 Converter to the CMS software Sur Gard MLR2 DG default and Ademco 685 are supported IP Defines the IP address assigned to the CMS Port Defi...

Страница 5: ...CMS software Generate Logs button Is used to generate logs for R D analysis and diagnosis It will generate a file called IPC10mainlogs ser Date zip that is saved on the PC in the downloads folder Ple...

Страница 6: ...orting to this receiver was terminated at the panel programming meaning dealer choose not to report to this receiver Account will also show as offline reported with default code 710 code can be modifi...

Страница 7: ...that are offline for over 30 days will be deleted from the account list by the converter The IPC10 supports up to 10 digit accounts in combination with future EVOHD and MGSP versions Suspend Account C...

Страница 8: ...rofile used in the registration process A maximum of 10000 is supported To Upgrade the IPC10 1 Click on the Upgrade icon 2 Browse for the upgrade firmware file that was downloaded from the Paradox web...

Страница 9: ...VDC Class 2 device Account Capacity 5 000 normal or long supervision 3 000 for high supervision Supervision Long 20 minutes 10 minutes Normal default 5 minutes High 90 seconds Supervision Message Offl...