Instructions 

ACM24D 4-Wire Access 

Control Module V1.0

The ACM24D Access Control Module can 
control two doors and can support REX devices, 
readers, locking devices and door contacts. 
Door contacts that are connected to the 
ACM24D are programmed using BabyWare 
software and can be assigned to zones in the 
Imperial system.

Installation

The ACM24D is a 
standard 35mm 
DIN rail module. 
Using the 
supplied DIN rail, 
the ACM24D can 
be mounted in any 
location. 
Alternatively, it 
can be mounted in 
a standard DIN rail enclosure. To attach the 
module, align the top of the DIN rail as shown in 
Figure 1 and apply pressure to the module until it 
clicks into place. To remove the ACM24D from a 
DIN rail, pull the release clip and remove the 
module.

To facilitate installation and servicing, the 
ACM24D terminals can be detached from the 
module. Wires can be labeled using the supplied 
tie wraps.

Door contacts connected to the system follow 
the control panel’s EOL definition. When EOL is 
enabled and door contacts are not used, place a 
1k

Ω

 resistor across the 

CT

 and 

C

 input terminals. 

If EOL is disabled, use a jumper. If the REX 
device is not used, place a jumper across the 

RX

 

and 

C

 terminals.

Stand-Alone Mode

The ACM24D stores all access codes and cards 
in memory. If panel communication is lost, the 
ACM24D will continue to function normally. 
Events will be stored in memory. When 
communication is restored, events are 
automatically uploaded to the panel.

Upgrading the Firmware

Imperial

The firmware of the ACM24D can be in-field 
upgraded through the V32’s RS485 ACCESS 
port using BabyWare. 

EVO/DGP

The ACM24D firmware can be upgraded through 
WinLoad using the CV4USB RS-485/RS-232 
Converter. Refer to the firmware upgrade 
instructions found at: paradox.com - Software - 
WinLoad - Firmware Upgrade Instructions.  

Imperial V32
EVO48, EVO192 
DGP-848, DGP-NE96, EVO96

Figure 1: DIN Rail Mounting

Release 
clip

35mm 
DIN rail

Communication LED Feedback

Bus

RX

TX

Condition

off

green - flash

green - flash OK (panel communication in progress)

off

off

off

OK (no data RX/TX)

red 

off

off

Short on GRN or YEL

red off

green

Communication failure / Too many modules on 
Multibus

red green

green

Multibus 

lines reversed (Green / Yellow)

red flash 

off

off

Bus power too low

red flash 

green - flash

green - flash Locate mode

blue ---

---

Communication 

with 

V32 panel / Multibus mode

blue flash

off

off

Firmware upgrade in progress

Power LED Feedback

LED

Colour

Condition

AC

green

AC or DC power is supplied

CHRG

green 

Battery is low / charging

green (less than 4 sec.)

Battery test

Door LED Feedback

DOOR1 and DOOR2 manual control buttons display door status and can override door 
programming. Manually unlocked doors remain unlocked for the minimum period 
programmed in BabyWare.

Colour

Condition

green on 

Door unlocked

red on

Door locked

Door Labels

Space is provided to label 
each door.

Fuse 

- not used

Detachable Terminals

Pry with screwdriver if 
necessary.

Locate Mode

For Imperial panels, a Module Locate can be started or stopped using BabyWare software 
or by pushing the module’s LOC button. When a Module Locate is initiated, a flashing 
occurs of the module’s LEDs (BUS RX and TX flash at 1Hz) as well as the module’s 
representation in BabyWare. 

For DGP/EVO panels, a Module Locate can  be initiated using section [4002] (EVO) or 
[952] (DGP-48 / DGP-848). To end a Module Locate, press the LOC button.

Reader LED Feedback

red flash 

Reader auxiliary power failure

red on

Reader is missing

green on 

Readers OK

off

No reader programmed for this door

Transformer Sharing

Modules can share a central AC 
transformer (16 to 24V

AC

) throughout the 

system. Ensure that the total power output 
of the transformer is respected.

.

16 / 24 Vac

16 / 24 Vac

ACM24D

ACM24D

Connect to other 
modules 
compatible with 
transformer 
sharing.

Transformer

EVO / DGP Programming

When used on an EVO/DGP system, the ACM24 appears in WinLoad as two ACM12 modules. 

Serial Numbers

Example: ACM24D = 3500556A  ACM12 #1 = 3500556

A

     

ACM12 #2 = 3500556

B

 (plus 1 number / letter)