Paradox GS250 Скачать руководство пользователя страница 1

Printed in Canada | 05/2010

GS250 Installation Guide | 1

GS250 Gsense Multi-axis
Movement Detector V1.0
Installation Guide

Overview

Figure 1: Front and rear views of the GS250.

Installation

Screw Mounting

1.

Press the release clip and remove the mounting bracket from 
the unit.

2.

Using the three mounting screws (provided), attach the 
mounting plate to the protected object. 

3.

Ensure that the battery is properly installed and clip the unit to 
the mounting plate.

Tape Mounting

1.

Press the release clip and remove the mounting bracket from 
the unit (see fig. 2).

Figure 2: Removing the mounting bracket.

2.

On the mounting bracket, break the four knock-outs and remove 
anti-tamper pin. Remove excess plastic (see fig. 3). 

Figure 3: Removing the anti-tamper pin.

3.

On the mounting tape, remove only the backing of the small 
center rectangle. Stick the anti-tamper pin to the small rectangle 
of mounting tape, and pull to separate it from the remaining 
mounting tape.

Figure 4: Affixing the anti-tamper pin.

4.

Position the mounting bracket on the protected object and stick 
the anti-tamper on the object. Ensure the correct orientation of 
the anti-tamper pin (see fig. 5).

Figure 5: Ensuring the correct orientation when positioning device.

5.

Apply the remaining mounting tape to the mounting bracket 
and stick the bracket to the protected object.

Figure 6: Affixing mounting bracket to the object.

LED Feedback

Test Mode

To enter test mode, simply insert the battery. If the battery is already 
inserted, use a pen to press and release the anti-tamper switch. The 
LED flashes red eight times quickly, signalling that the unit has 
entered test mode. The LED’s flash sequence is described in table 3.

NOTE: 

The unit will exit test mode after 15 minutes, or after it has 

been inactive for a period of five minutes.

Power Saving Mode

If two consecutive alarms occur within a five-minute period, the unit 
goes into power saving mode for a period of three minutes. If a 
movement is detected while in power saving mode, the LED emits 
one red flash. No detection signals are transmitted to the panel.

Table 1: The components of the GS250

Item

Name

A

Release  clip

B

Status LED (movement, tamper, sensitivity programming)

C

Anti-tamper switch

D

Battery compartment

E

Battery pry slot

F

Mounting  bracket

G

Anti-tamper  pin 

A

B

C

D

E

F

G

Front View

Rear Exploded View

Table 2: LED feedback on the GS250

LED

Flash Sequence

Description

Red

On for 3 seconds

Alarm in normal mode

Red

Fast flash

Alarm in power saving mode

Table 3: LED’s flash sequence on the GS250

LED

Flash Sequence

Description

Red

3 x 8 fast flash

Power up

Amber 1 x flash per 5 seconds In test mode

Green

1 fast flash

Movement detected

Red

8 x fast flash

Tamper open

Red

8 x fast flash

Tamper closed

Red

8 x fast flash

Zone closed

Red

3 seconds On

Enough movement has occurred 
to trigger an alarm

GS250-EI00