EVOHD+ Installation Guide
67
Burglar Alarm On Forced Door or Door Left Open
S
ECTION
[3038]: O
PTION
[5] (F
ORCED
D
OOR
)
S
ECTION
[3038]: O
PTION
[7] (D
OOR
L
EFT
O
PEN
)
(default =
disabled
) If an Access Door is forced open or left open, a signal can be sent to the control panel to trigger the burglar alarm. The burglar alarm is
generated instantly regardless of the zone’s definition.
For these features to function:
•
Install a door contact and connect it to the door’s Access Control Module
•
Assign the Access Control Module to a zone (See “Zone Programming” on page 20.)
•
Enable option
[5]
in section
[3038]
: Burglar Alarm on Forced Door
•
Enable option
[7]
in section
[3038]
: Burglar Alarm on Door Left Open
Logging Access Control Events
Log Request For Exit In Event Buffer
S
ECTION
[3038]: O
PTION
[2]
(default =
disabled
) When enabled, the control panel can record the REX events generated from all the Doors in the Event Buffer, but cannot report these events to
the monitoring station. The events can be viewed by entering the
Event Record Display
.
NOTE:
Since REX events can occur often, the Event Buffer may fill up quickly.
Log Door Left Open Restore In Event Buffer
S
ECTION
[3038]: O
PTION
[3]
(default =
disabled
) When enabled, the Door Left Open Restore event can be recorded in the Event Buffer. These events cannot be reported to the monitoring
station, but can be viewed by entering the
Event Record Display
.
Log Door Forced Open Restore In Event Buffer
S
ECTION
[3038]: O
PTION
[4]
(default =
disabled
) When enabled, the Door Forced Open Restore event can be recorded in the Event Buffer. This event cannot be reported to the monitoring
station, but it can be viewed by entering the Event Record Display.