EVOHD+ Installation Guide
Door Access Mode
S
ECTION
[2251]
TO
[2282]: O
PTION
[1]
Access Door and user can be assigned to one or more partitions in the security system. Actions performed by the user will be directly linked to the partition(s)
assigned to that door. Doors 01 to 32 are programmed in sections
[2251]
to
[2282]
respectively.
Code Access
S
ECTION
[2251]
TO
[2282]: O
PTION
[2]
Code Access can allow access to an Access Door by entering a valid user access code and pressing the
[
ACC
]
key on a K641 LCD Keypad instead of using the Access
Card. The control panel will verify its assigned Access Level and Schedule. Doors 01 to 32 are programmed in sections
[2251]
to
[2282]
respectively.
Card and Code Access
S
ECTION
[2251]
TO
[2282]: O
PTION
[3]
The Access Door can be programmed to require a user to present a valid Access Card and then enter the user’s valid code on a R915 that is connected to an Access
Control Module (ACM12). The R915 and the Access Control Module must be correctly configured. Please refer to the R915 “Installation and Operating Instructions”,
and to the Access Control Module “Reference & Installation Manual” for instructions. Doors 01 to 32 are programmed in sections
[2251]
to
[2282]
respectively.
NOTE:
When option [3] is enabled, the Access Card must be presented
before
the user access code is entered.
Skip Exit Delay When Arming With Access Card
S
ECTION
[3038]: O
PTION
[6]
(default =
disabled
) When arming with an Access Card, the system can arm with or without starting the Exit Delay.
Restrict Arming on Door
S
ECTION
[2251]
TO
[2282]: O
PTION
[4]
With option
[4]
ON, the control panel can prevent an Access Card from arming the partition(s) assigned to the door even if the Access Card is programmed to permit
arming.
Restrict Disarming on Door
S
ECTION
[2251]
TO
[2282]: O
PTION
[5]
With option
[5]
ON, the control panel can prevent an Access Card from disarming the partition(s) assigned to the door even if the Access Card is programmed to
permit disarming.
Door Access During Clock Loss
S
ECTION
[3038]: O
PTION
[8]
(default =
disabled
) If the system registers a Clock Loss Trouble, the control panel will no longer recognize the Schedules until the clock is reset. Enable or disable
the option as required:
[1]
ON
“OR” Access Door
The Access Door grants access or permits arming or disarming to users
assigned to
at least one
of the door’s partitions. An “OR” door will arm
or disarm only the partitions that it has in common with the users.
[1]
OFF
“AND” Access Door
The Access Door grants access or permits arming
only
to users
assigned to
all
the door’s assigned partitions.
[2]
ON
[
ACC
]
key enabled
[2]
OFF
Access with Card only
[3]
ON
Access Card AND User Access Code required
[3]
OFF
Access Card OR User Access Code
[6]
ON
The Exit Delay is cancelled
[6]
OFF
The Exit Delay is triggered
Option
Until the Clock is reset, access can be granted to:
[8]
ON
The System Master or User Access Code with Master feature or
Schedule 00 (00 = all times) enabled
[8]
OFF
All users regardless of their programmed Schedules