12
Programming Guide
System Programming
System Timers
[749]
____/____/____
(000 to 255) x 15 minutes
Partition 1 no movement (default 000)
[750]
____/____/____
(000 to 255) x 15 minutes
Partition 2 no movement (default 000)
Section
Data
Description
[761]
____/____:____/___
HH: MM
Auto-arm on time Partition 1 (default 00:00)
[762]
____/____:____/____
HH: MM
Auto-arm on time Partition 2 (default 00:00)
[700]
General System Options
Option
OFF
ON
[3]
Audible trouble warning (except AC failure)
N
Disabled
N
Enabled
[4]
Audible trouble warning on AC failure
N
Disabled
N
Enabled
[6]
Exit delay termination
N
Disabled
N
Enabled
[7]
Tamper supervision on the bus module
N
Disabled
N
Enabled
[702]
Panic Options
Option
OFF
ON
[1]
Panic 1
Disabled
N
Enabled
[2]
Panic 2
Disabled
N
Enabled
[3]
Panic 3
Disabled
N
Enabled
[4]
Panic 1: Report only or audible alarm
Report only
N
Audible
[5]
Panic 2: Report only or audible alarm
Report only
N
Audible
[6]
Panic 3: Report only or audible alarm
Report only
N
Audible
[703]
Arming/Disarming Options 1
Option
OFF
ON
[5]
Restrict arming on battery failure
Disabled
N
Enabled
[6]
Restrict arming on tamper failure (Zone + Bus Module)
Disabled
N
Enabled
[8]
Calling the VDMP3
N
Disabled
Enabled
[704]
Arming/Disarming Options 2
Option
OFF
ON
[1]
Regular arming switches to force arming
N
Disabled
Enabled
[2]
Stay arming switches to stay force arming
N
Disabled
Enabled
[3]
Sleep arming switches to sleep force arming
N
Disabled
Enabled
Section Data
Description
[710]
____/____/____
(000 to 255) seconds
Entry delay 1 (default 045)
[711]
____/____/____
(000 to 255) seconds
Entry delay 2 (default 045)
[712]
____/____/____
(000 to 015)
Auto zone shutdown counter (default 005)
[713]
____/____/____
(000 to 255) seconds
Intellizone delay (default 048)
[714]
____/____/____
(000 to 255) minutes
Recycle alarm delay (default 000)
[715]
____/____/____
(000 to 255)
Recycle alarm counter (default 000)
[718]
N/A
N/A
N/A
[719]
____/____/____
(000 to 255) days
Closing delinquency delay (default 000)
[720]
____/____/____
(000 to 255) seconds
For StayD: Flex-Instant delay (default 015)
[721]
____/____/____
(000 to 255) seconds
For StayD: Re-arm delay (default 005)
Section Data
Description
See Quick Menus on page 39