background image

NV

X

80

 

High End Motion Detector with Anti-Mask for Indoor/Outdoor Use V1.02

Reference and Installation Manual

PARADOX.COM

Printed in Canada - 03/2013

NVX80-EI00

Содержание ENVY NVX80

Страница 1: ...NVX80 High End Motion Detector with Anti Mask for Indoor Outdoor Use V1 02 Reference and Installation Manual PARADOX COM Printed in Canada 03 2013 NVX80 EI00...

Страница 2: ...ox product signifies your acceptance of all warranty terms and conditions ENVY Series is a trademark or registered trademark of Paradox Ltd or its affiliates in Canada the United States and or other c...

Страница 3: ...dox s proven Pet Immunity active for false alarm rejection in the short and medium detection ranges note Creep Zone detection neutralized 3rd generation Paradox digital detection technology delivering...

Страница 4: ...4 NVX80 Version 1 02 Beam Patterns...

Страница 5: ...r 1 1 lbs Construction Materials ASA UV Resistant Tamper Positioning Cover and Wall RF Immunity 20 V m up to 2 7 GHz Operating Temperature 35 to 60 C 31 to 140 F Bus Connection EVO192 panel Certificat...

Страница 6: ...to the wall surface using mounting screws appropriate for the specific installation 9 Slide the front section of the unit into place on the back cover of the unit If the wires are connected to electri...

Страница 7: ...direct the unit s beams into swaying trees or bushes Don t place the detector facing direct sunlight or near a heat source as it might interfere with the Active IR anti mask feature Don t place any o...

Страница 8: ...necting to the Bus Connecting to the Digiplex bus is quite straight forward The red black green and yellow wires must be placed into the red black green and yellow slots respectively 8 NVX80 Version 1...

Страница 9: ...n The following items are included in the NVX80 main menu PIR Microwave Anti Mask Alarm Condition Input Output Diagnostics Settings About and Language Via the menu these features can be activated sens...

Страница 10: ...10 NVX80 Version 1 02 Menu Tree...

Страница 11: ...Relay 2 Function Relay 2 is a solid state relay Select events from a list to activate this relay Relay 2 Logic Select N C or N O Remember Relay 2 will open when power is lost Relay 3 Function Relay 3...

Страница 12: ...a button Setting changes occur once the OK button is pushed Changes will not be saved if the back button is pushed Diagnostics Menu Action Test All Tests all detection functions Shows PIR MW and Anti...

Страница 13: ...y of the lens movement within close range of the unit and the degradation of the lens by dirt or dust by 50 from factory set levels The NVX80 anti mask technology protects the detector from a wide ran...

Страница 14: ...by an Alarm event triggered by the main lens An Active IR anti mask has a higher display priority If Active IR and MW anti mask events occur simultaneously then the blue frame will appear instead of a...

Страница 15: ...shown in Test and Operation Mode after PIR and MW Pre Alarm PIR Pre Alarm in Operation MW Anti Mask Pre Alarm in Test and Operation Mode Creep alarm as shown in Test and Operation Mode Alarms When an...

Страница 16: ...Small Pet Up to 15 kg 33 lbs Medium Pet Up to 20 kg 44 lbs Large Pet Creep Zone Select Creep Zone sensitivity 1 lowest to 5 highest 1 for 2 5 m installations 5 for 3 5 m installations Test PIR Test th...

Страница 17: ...the movement small and large animals up to 20 kg 44 lbs in both indoor and outdoor environments By ignoring the movement of the pets the detector s reliability increases MW Sensitivity Select sensiti...

Страница 18: ...tector will enter menu mode after the power up sequence is over After closing the Wall Tamper this message will appear When any of the tampers are detected as open a relay configured as a Tamper will...

Страница 19: ...in lens transparency i e below 50 of factory set levels If this condition exists this message will appear at the end of the power up sequence Appears in Operation Mode if any of the Digiplex wires are...

Страница 20: ...us BUS zone Shows the zone number set for each of the three relays future Information specific to your individual NVX80 detector can be found in the About Us section Use the diagram below to upload fi...

Отзывы: