INSTALLATION GUIDE OF EB-N94 FOUR-ELEMENT
INTELLIGENT PIR INTRUSION DETECTOR
Lens
Walk-test LED
PIR
LED
Code switch
Sensitivity adjust
Figure 1.General View
Figure 2.Inside View
2.Specifications
Top view
Side view
Connect terminals
Models: EB-N94
Input Voltage
9-16VDC
Cyrrent Drain
30mA@ 12VDC
Detection Range
11.6m*11.6m
Alarm output
NC.>100mA/28VDC
Anti white light resistance
>1000000LUX
Installation height:2m-2.7m
Tamper switch NC.100mA/28VDC
PIR Section:Lens Date
NO.of Curtain Beams (11+11+9)*2=62
Tripping Indication:
lndicator lights for about 10-30 seconds
Anti -EMI/RFI
10V/m
10MHz-1000MHz
Motion test
0.2m/s-3.5m/s(0.6ft-11ft)
Humidity
5%-95%
RH
Accessories:
BR-1:Surface mounted swivel bracket,adjustable 30
down and 45 left/right.
Environmental:
Operating Temp: -10
C to 50 C(14
F to 122 F )
Storage Temp :-20
C to 60 C (-4
F to 40 F)
Physical
Size(H*W*D):176*85*69mm
3.Installation
3.1 General Guidelines
No direct facing cold
/hot source
No direct sun shine
Keep away from high
pressure power
No facing metal wall
Installation base
should be stable
1.Brief Introduction
EB-N94 is a kind of PIR intrusion detector integrating the most
advance d security technology. It adopts 2 dual PIR sensors with
high accuracy, intelligent digi-tal chip, advanced ,<True Motion
Recognition & Anti-pests>of tware technology, which can help
it to make an accurate judgment of trueintruder or other interfer
-ence that can cause wrong alarm. And it is with function of auto
-matic memory of environmental change, which can avoid wro
-ng alarm a used by hot & cold air, opera-tion machine interfere
-nce. It can prevent effectively the interference cause by a 25 kg
past or 10 cats, insect, mouse, birds etc. Its super filter can be
used indoor and outdoor. This has clear various interference
that com-mon PIR detector can't overcome; and put an end to
wrong alarm and miss alarm .EB-N94 has two different working
modes: bus mode and relay mode, can be used for all kinds of
control panels on the market.
This device is coherent to Europe parliament direct 1999/5/EC
necessary items and rules, and also coherent to the main spirits
th
of radio and telecom terminal equipments on March 9 . 1999.
The device also reaches the Canadian standard RSS-210. It can
be used indoor and outdoor, which can reach its maximum prote-
ction and avoidance of above interference.
3. 2Anti-pests installation
The upper part of the
detection area is non
anti-pests area
Never face the detector to
the place that pests can
climb up directly
20Kg
Anti-pests weight
The installation height
of the detector is 2.2-2.4
meters can Anti-pests