I

N TRO DU CTION

The  Digital Vision 525 D series comb ine s  a superior performance
in frared m otion det ect or w ith a state -of-the-art  microwa ve  detection
unit. The Digital Vision 52 5D mo tion  detector include s t he following
unique fe ature s:

-

100 % Digital Motion D etection 

-

Digita l Sh ield™  algorithm  so ftware

-

Digita l M icro wave D etection 

-

Digita l Au to Pulse  Sign al  Processing  (Pate nted)

-

Digita l Temp erat ure C ompe nsatio n

WA RNING:  D

O

 

N O T

 

TO U C H

 

T H E

 

S EN S O R

 

S U R F A C E

 

A S

 

T H IS

 

C O U LD

R E S U LT

 

IN

 

A

 

D ET E C TO R

 

MA L FU N C TIO N

. I

F

 

N E C E S SA R Y

C LE A N

 

T H E

S E N S O R

 

S U R FA C E

 

U S I N G

 

A

 

S O F T

 

C LO TH

 

W IT H

 

PU R E

 

A L C O H O L

.

J

U M PER

 S

ETTIN GS

Para dox 

Digital Visi on 525D

 detectors  are e quipped w ith

four jumpers, used  to set  the op erat ion al  modes  of the
detector. In the fo llowing inst ructions, jumpe r sett ing s are
refe red to as being eit her ON or OFF. Also  use the PC B
la you t dra wing (FIG-1) to  lo cat e ju mpers.

J1 - S

ING L E

 

O R

 D

UA L

 E

DG E

 P

RO CESSING

J1  determines the D SP (D igita l Signal Processing) operational setting
for  the mot ion  detector.

ON (de fault)

 

=

  In "Single edg e"  processin g ent ry and  exit  signa ls are

added  until t he value re presen ting  an alarm situ atio n is reached.

OFF =

 In "Dual edge " processing, en try signa ls are processed

se para tely from e xit signals.  Both have t o rea ch  requ ired en ergy
le vels befo re an  alarm  is gen erate d.

J2 - D

IG ITA L

 S

H IEL D

™ S

ETTING

The  SH IELD ™ jumper sets several Digital Processing  pa rame ters
su ch  as:
-

Accumu lat ed energy leve ls required  to gen erate  an alarm

-

EMI/RFI digital filter leve ls

-

Digita l a mplifier gain.

ON (de fault) =

 Th is w ill activa te “Normal Mod e”,  which should  be set

when  being used in a  “N orma l” Environme nt.

OFF =

 In  "H ig h Shield" mo de,  all t hree  paramete rs m entioned  above

are  a utomat ically set for h igh -risk environme nts (poten tial
in terfe rence).

J3 - T

EST

 M

O DES

J3  is used fo r the M icrowave an d Infrared  Test M odes as sh own in
FIG-5 (see  other side ).

J4 - LED S

ETTING

ON (default) =

 This w ill enab le t he re d LED.

OFF =

 This  will disable the red LED .

I

NSTAL LATIO N

Using a Paradox® stand ard lens at the recomme nded installation
height of 2.1m (7ft) ±10%, the Para dox D igital Visio n de tector will
provide  full coverage from 1.5m (5ft) to 14m  (45ft) w ithout any dead
zones (FIG-3).

Avoid  placing  the  detector in  proximity t o th e f ollow ing  sources  of
interferen ce : reflective  su rfaces, dire ct a ir flow, sources of stea m/oil
vapor, infrare d light  so urces and o bje cts causing temp erat ure
change s. Digital Microw ave D etection will be h ampered if installed
clo se  to vibrating me tal  surfaces, ro tating fans, w ater flo w in plumbing
pipes or electrom agnetic sou rces. Also note, microw ave freq uencie s
can pen etrat e walls, t here fore,  avo id installing  the unit wh ere  it can
re sp ond  to m otio n on  the  oth er  side  of  the  pro tected a rea's w alls. To
change  the lens, choose the d esired lens (see ht tp://ww w.paradox.ca)
and  perfo rm t he follo wing (FIG-1):

a) rem ove the front cover of the d etector (1) by gently pushing the

co ve r pin (2) in w it h a screw driver.

b) pull ou t the bezel (4) by lightly pressin g on the b ezel pins (5) & (6).

c) rem ove the lens and  replace it with t he altern ate lens. (N ote: w hen

the ne w lens is properly installed , the grooves should be inside the
bezel and th e le ns ca talo gue num ber  on top.)

d) rep lace the bezel by lightly p ressin g into place a nd verify that the

le ns is centered.

After selecting t he d etector's location,  drill  or pu nch  out  holes  for  the
screw s a s d escribe d below  (see FIG-1 a nd FIG-4 on  the oth er side).

COR NER  MOU NT: 

Carefully remove the PCB (9 ) by loosening PCB

screw  (12) and  utilize holes A, B, C  and D .

FLAT SU RFA CE  MOU NT:

 C aref ully rem ove the PCB (9) b y loosening

PCB scre w (12) a nd utilize ho les E, F, G an d H.

WIR ING:

 Ru n t he wires thro ugh entry holes I & J and connect them

according  to the m arkings on the  plast ic back and  as  per FIG-2 .

T

U RN ING

 

ON

 

TH E

 P

A RAD OX

 D

IG ITAL

 V

ISIO N

 D

ETECTO R

Turning on the dete cto r in itiates a se lf-testing prog ram  for the sign al
processor an d mem ory. The LED  will  flash  for 16  se co nds. When  the
LED  is no  lon ger flashing, th e system  is ready and  fully operational.

M

ICR OW AVE

 W

AL K

-

TESTING

Ensure th at J1 is ON and insert a ju mper be tween  J2 and J3 a s
described in FIG-5 (se e other side). After cha nging the setting, allow 3
seconds for the chang es to take effect.

Walk-test the  protected a rea  while mon ito ring th e red LED .  If  the  red
LED  is flashing rapidly, it mean s that it is de tecting  low level sig nals,
wh ich are not stro ng enou gh to gen erate  an alarm . Reduce
microw ave sen sitivity by using a sm all flat scre wdriver to  tu rn the
PCB's microw ave sensitivity trim mer (FIG-1 )  cou nterclockwise  until a
minimum re quired sensitivity is achieved, while  ma inta ining sufficient
dete ction response. If the micro wave detector is too sensitive,  it will
dete ct m ovement  from  outsid e the w alls of th e protected area. The
microw ave rang e (sensitivity) can be adjusted. Un like the infra red
dete cto r, microw ave det ect ion  is  se nsitive to  movemen t app roaching/
re ce din g fro m the de tector. 

After the w alk-test, perform  a  non-movement  test. After corre ct
sensit ivity  adjust ment, th e re d LED sho uld  not illum inat e. If it doe s,
this m eans t hat the microwa ve det ect or is dete cting movem ent or
interferen ce  from som ewhe re in side or outside the prote cte d area.
Interference may be  generated b y electromagn etic sources o r mo ving
objects, even if they are  locate d out of view. In this case, try to
re locate  the  det ect or. U pon  completion  of t he m icrowave  walk-te st
re move the  jum per b etwee n J2 and J3.

I

NF RAR ED

 W

A LK

-

TESTIN G

Set J1 to OFF, and insert a  jum per b etwee n J2 and J3 as described  in
the FIG-5  (see o ther  side). After changing th e setting allow 3 second s
for the chan ges to take effe ct.

At 20°C  (room  temperature),  you  sh ould not b e able to cross m ore
than  one comp let e zone (co nsisting of  2 beam s) in the coverage a rea
with an y kind of m ovement; slow/f ast  walking  or running. App roximate
width of a f ull beam at 14m (4 5ft) from the detector is 1.8 m (6ft) see
FIG-3. Up on co mpletion of walk test ing  remove the  jump er betw een
J2 and  J3.

Warrant y
The Seller warrants  its product s  to be f ree  from  defect s  in  materials  and workmanship under  normal use

for a period  of  one year.  Except as  specif ically stat ed herein,  all  express or  implied warranties

whatsoever,  statut ory or ot herwise, including wit hout  l imitation, any implied warranty of merchant abilit y

and fit ness for a parti cular purpose,  are expressly excluded. Because Seller does not  i nstall or connect

the products and because the products m ay be used in conjuncti on wi th products not manuf actured by

the S eller. Seller cannot guarant ee the perf ormance of  t he securit y system.  S el ler obligation and li abilit y

under this warranty is expressly limi ted to repairing  or replacing,  at S ell er’s opt ion,  any product s not

meeting t he speci ficat ions. In no event  shall the S el ler be liabl e to the buyer or any ot her person f or any

losses or damages whether direct or indirect or consequent ial or incident al , including without  limitat ion,

any damages f or lost profit s stolen goods, or claims by any ot her party,  caused by def ecti ve goods or

otherwise arising from  t he improper,  incorrect  or ot herwise faulty installation or use of  t he merchandise

sol d.

100% Digital M otion Detection: patented
†Interlock  Sensor  Geometr y: patented
†Auto Puls e Signal Processing: patented
†One or  m or e of the following US patents may apply: 6215399, 6111256,
5287111, 5119069, 5077549, 5920259, 5886632, US05751803, US05721542,
US05287111, US05119069, and US 05077549. Canadian and International
patents may also apply: patent #1-302-541 (CA N)
*LODIFF® lens: patent #4,787,722 (U.S .)
LODIFF® a registered trademark of Fresnel Tec hnologies Inc.
Digital Vision is a trademark of P aradox S ecurity  S ystems
Specifications may change without prior notice
© 2002 Paradox Security Sy stem s  

This dev ice complies with Part 15 Subpart (B ) of FCC Rules . Operation is
subject to the following two conditions: (1) this dev ice may not c ause harm ful
interference, and (2) this device m us t acc ept any inter ferenc e received,
including interference that m ay c ause undesir ed oper ation. 

The user is cautioned that any  changes or m odific ations not expres sly
approved by  Paradox Security  Sys tems  could void the user’s authority to
operate/use the equipment.

TECHNICAL SPECIFICATIONS

M otion Detector type

P IR + Mic rowave

PIR Sens or element type

Dual

Sensor geom etry

Rectangular

Focal point lens

1.2”

Range (90° Standard lens)

14m x 14m (45ft x 45ft)

M icrowav e Antenna type

Flat strip microwave antenna with FE T osc illator

Frequenc y

FCC & DOC - 10.525GHZ, (other frequencies
available)

Oper ating Tem perature

- 20° to +50°C ( -4° to+122°F)

Voltage

10 -  16VDC

Cur rent Cons um ption

30mA m aximum

Alarm form  A output

Standard 150mA , 28V DC

Alarm form  C output

N.C. 150mA , 28VDC (optional)

Tamper form  C output

N.C. 150mA , 28VDC (optional)

Alarm period

3 sec.