The Digital Vision 525 D series comb ine s a superior performance
in frared m otion det ect or w ith a state -of-the-art microwa ve detection
unit. The Digital Vision 52 5D mo tion detector include s t he following
unique fe ature s:
-
100 % Digital Motion D etection
-
Digita l Sh ield™ algorithm so ftware
-
Digita l M icro wave D etection
-
Digita l Au to Pulse Sign al Processing (Pate nted)
-
Digita l Temp erat ure C ompe nsatio n
WA RNING: D
O
N O T
TO U C H
T H E
S EN S O R
S U R F A C E
A S
T H IS
C O U LD
R E S U LT
IN
A
D ET E C TO R
MA L FU N C TIO N
. I
F
N E C E S SA R Y
,
C LE A N
T H E
S E N S O R
S U R FA C E
U S I N G
A
S O F T
C LO TH
W IT H
PU R E
A L C O H O L
.
J
U M PER
S
ETTIN GS
Para dox
Digital Visi on 525D
detectors are e quipped w ith
four jumpers, used to set the op erat ion al modes of the
detector. In the fo llowing inst ructions, jumpe r sett ing s are
refe red to as being eit her ON or OFF. Also use the PC B
la you t dra wing (FIG-1) to lo cat e ju mpers.
J1 - S
ING L E
O R
D
UA L
E
DG E
P
RO CESSING
J1 determines the D SP (D igita l Signal Processing) operational setting
for the mot ion detector.
ON (de fault)
=
In "Single edg e" processin g ent ry and exit signa ls are
added until t he value re presen ting an alarm situ atio n is reached.
OFF =
In "Dual edge " processing, en try signa ls are processed
se para tely from e xit signals. Both have t o rea ch requ ired en ergy
le vels befo re an alarm is gen erate d.
J2 - D
IG ITA L
S
H IEL D
™ S
ETTING
The SH IELD ™ jumper sets several Digital Processing pa rame ters
su ch as:
-
Accumu lat ed energy leve ls required to gen erate an alarm
-
EMI/RFI digital filter leve ls
-
Digita l a mplifier gain.
ON (de fault) =
Th is w ill activa te “Normal Mod e”, which should be set
when being used in a “N orma l” Environme nt.
OFF =
In "H ig h Shield" mo de, all t hree paramete rs m entioned above
are a utomat ically set for h igh -risk environme nts (poten tial
in terfe rence).
J3 - T
EST
M
O DES
J3 is used fo r the M icrowave an d Infrared Test M odes as sh own in
FIG-5 (see other side ).
J4 - LED S
ETTING
ON (default) =
This w ill enab le t he re d LED.
OFF =
This will disable the red LED .
I
NSTAL LATIO N
Using a Paradox® stand ard lens at the recomme nded installation
height of 2.1m (7ft) ±10%, the Para dox D igital Visio n de tector will
provide full coverage from 1.5m (5ft) to 14m (45ft) w ithout any dead
zones (FIG-3).
Avoid placing the detector in proximity t o th e f ollow ing sources of
interferen ce : reflective su rfaces, dire ct a ir flow, sources of stea m/oil
vapor, infrare d light so urces and o bje cts causing temp erat ure
change s. Digital Microw ave D etection will be h ampered if installed
clo se to vibrating me tal surfaces, ro tating fans, w ater flo w in plumbing
pipes or electrom agnetic sou rces. Also note, microw ave freq uencie s
can pen etrat e walls, t here fore, avo id installing the unit wh ere it can
re sp ond to m otio n on the oth er side of the pro tected a rea's w alls. To
change the lens, choose the d esired lens (see ht tp://ww w.paradox.ca)
and perfo rm t he follo wing (FIG-1):
a) rem ove the front cover of the d etector (1) by gently pushing the
co ve r pin (2) in w it h a screw driver.
b) pull ou t the bezel (4) by lightly pressin g on the b ezel pins (5) & (6).
c) rem ove the lens and replace it with t he altern ate lens. (N ote: w hen
the ne w lens is properly installed , the grooves should be inside the
bezel and th e le ns ca talo gue num ber on top.)
d) rep lace the bezel by lightly p ressin g into place a nd verify that the
le ns is centered.
After selecting t he d etector's location, drill or pu nch out holes for the
screw s a s d escribe d below (see FIG-1 a nd FIG-4 on the oth er side).
COR NER MOU NT:
Carefully remove the PCB (9 ) by loosening PCB
screw (12) and utilize holes A, B, C and D .
FLAT SU RFA CE MOU NT:
C aref ully rem ove the PCB (9) b y loosening
PCB scre w (12) a nd utilize ho les E, F, G an d H.
WIR ING:
Ru n t he wires thro ugh entry holes I & J and connect them
according to the m arkings on the plast ic back and as per FIG-2 .
T
U RN ING
ON
TH E
P
A RAD OX
D
IG ITAL
V
ISIO N
D
ETECTO R
Turning on the dete cto r in itiates a se lf-testing prog ram for the sign al
processor an d mem ory. The LED will flash for 16 se co nds. When the
LED is no lon ger flashing, th e system is ready and fully operational.
M
ICR OW AVE
W
AL K
-
TESTING
Ensure th at J1 is ON and insert a ju mper be tween J2 and J3 a s
described in FIG-5 (se e other side). After cha nging the setting, allow 3
seconds for the chang es to take effect.
Walk-test the protected a rea while mon ito ring th e red LED . If the red
LED is flashing rapidly, it mean s that it is de tecting low level sig nals,
wh ich are not stro ng enou gh to gen erate an alarm . Reduce
microw ave sen sitivity by using a sm all flat scre wdriver to tu rn the
PCB's microw ave sensitivity trim mer (FIG-1 ) cou nterclockwise until a
minimum re quired sensitivity is achieved, while ma inta ining sufficient
dete ction response. If the micro wave detector is too sensitive, it will
dete ct m ovement from outsid e the w alls of th e protected area. The
microw ave rang e (sensitivity) can be adjusted. Un like the infra red
dete cto r, microw ave det ect ion is se nsitive to movemen t app roaching/
re ce din g fro m the de tector.
After the w alk-test, perform a non-movement test. After corre ct
sensit ivity adjust ment, th e re d LED sho uld not illum inat e. If it doe s,
this m eans t hat the microwa ve det ect or is dete cting movem ent or
interferen ce from som ewhe re in side or outside the prote cte d area.
Interference may be generated b y electromagn etic sources o r mo ving
objects, even if they are locate d out of view. In this case, try to
re locate the det ect or. U pon completion of t he m icrowave walk-te st
re move the jum per b etwee n J2 and J3.
I
NF RAR ED
W
A LK
-
TESTIN G
Set J1 to OFF, and insert a jum per b etwee n J2 and J3 as described in
the FIG-5 (see o ther side). After changing th e setting allow 3 second s
for the chan ges to take effe ct.
At 20°C (room temperature), you sh ould not b e able to cross m ore
than one comp let e zone (co nsisting of 2 beam s) in the coverage a rea
with an y kind of m ovement; slow/f ast walking or running. App roximate
width of a f ull beam at 14m (4 5ft) from the detector is 1.8 m (6ft) see
FIG-3. Up on co mpletion of walk test ing remove the jump er betw een
J2 and J3.
Warrant y
The Seller warrants its product s to be f ree from defect s in materials and workmanship under normal use
for a period of one year. Except as specif ically stat ed herein, all express or implied warranties
whatsoever, statut ory or ot herwise, including wit hout l imitation, any implied warranty of merchant abilit y
and fit ness for a parti cular purpose, are expressly excluded. Because Seller does not i nstall or connect
the products and because the products m ay be used in conjuncti on wi th products not manuf actured by
the S eller. Seller cannot guarant ee the perf ormance of t he securit y system. S el ler obligation and li abilit y
under this warranty is expressly limi ted to repairing or replacing, at S ell er’s opt ion, any product s not
meeting t he speci ficat ions. In no event shall the S el ler be liabl e to the buyer or any ot her person f or any
losses or damages whether direct or indirect or consequent ial or incident al , including without limitat ion,
any damages f or lost profit s stolen goods, or claims by any ot her party, caused by def ecti ve goods or
otherwise arising from t he improper, incorrect or ot herwise faulty installation or use of t he merchandise
sol d.
100% Digital M otion Detection: patented
†Interlock Sensor Geometr y: patented
†Auto Puls e Signal Processing: patented
†One or m or e of the following US patents may apply: 6215399, 6111256,
5287111, 5119069, 5077549, 5920259, 5886632, US05751803, US05721542,
US05287111, US05119069, and US 05077549. Canadian and International
patents may also apply: patent #1-302-541 (CA N)
*LODIFF® lens: patent #4,787,722 (U.S .)
LODIFF® a registered trademark of Fresnel Tec hnologies Inc.
Digital Vision is a trademark of P aradox S ecurity S ystems
Specifications may change without prior notice
© 2002 Paradox Security Sy stem s
This dev ice complies with Part 15 Subpart (B ) of FCC Rules . Operation is
subject to the following two conditions: (1) this dev ice may not c ause harm ful
interference, and (2) this device m us t acc ept any inter ferenc e received,
including interference that m ay c ause undesir ed oper ation.
The user is cautioned that any changes or m odific ations not expres sly
approved by Paradox Security Sys tems could void the user’s authority to
operate/use the equipment.
TECHNICAL SPECIFICATIONS
M otion Detector type
P IR + Mic rowave
PIR Sens or element type
Dual
Sensor geom etry
Rectangular
Focal point lens
1.2”
Range (90° Standard lens)
14m x 14m (45ft x 45ft)
M icrowav e Antenna type
Flat strip microwave antenna with FE T osc illator
Frequenc y
FCC & DOC - 10.525GHZ, (other frequencies
available)
Oper ating Tem perature
- 20° to +50°C ( -4° to+122°F)
Voltage
10 - 16VDC
Cur rent Cons um ption
30mA m aximum
Alarm form A output
Standard 150mA , 28V DC
Alarm form C output
N.C. 150mA , 28VDC (optional)
Tamper form C output
N.C. 150mA , 28VDC (optional)
Alarm period
3 sec.