NOTE 2:
The TLM trouble event can only be used with DGP-NE96 control panel models that have two dialers.
NOTE 3:
The TLM trouble event can only be used with DGP-NE96 control panel models that have one dialer.
NOTE 4:
This event cannot be used for a module’s PGM programming.
*
:
If a Keyswitch Input is used, the input must be defined as “Generates a Utility Key Event on Open” or “Generates a Utility Key Event on Open
and Close”. If a remote control is used, the remote control button must be defined as a Utility Key button.
†
:
Actions that Activate a Utility Key Event:
** Keyswitch
‡
Refer to the MG-RCV3
Reference and Installation Manual
for remote control button programming instructions.
Utility Key Event
Actions
Keypad Utility Keys
Keyswitch Inputs
(definition = [3])
Keyswitch Inputs
(definition = [4])
Remote Control
Utility Key Event 1
[1] & [2]
KS** Input 1 opens
KS** Input 1 opens
Utility Key 1 RC button
‡
Utility Key Event 2
[4] & [5]
KS** Input 2 opens
KS** Input 1 closes
Utility Key 2 RC button
‡
Utility Key Event 3
[7] & [8]
KS** Input 3 opens
KS** Input 2 opens
Utility Key 3 RC button
‡
Utility Key Event 4
[
CLEAR
] & [0] or [*] & [0]
KS** Input 4 opens
KS** Input 2 closes
Utility Key 4 RC button
‡
Utility Key Event 5
[2] & [3]
KS** Input 5 opens
KS** Input 3 opens
Utility Key 5 RC button
‡
Utility Key Event 6
[5] & [6]
KS** Input 6 opens
KS** Input 3 closes
N/A
Utility Key Event 7
[8] & [9]
KS** Input 7 opens
KS** Input 4 opens
N/A
Utility Key Event 8
[0] & [
ENTER
] or [0] & [#]
KS** Input 8 opens
KS** Input 4 closes
N/A
Utility Key Event 9
N/A
KS** Input 9 opens
KS** Input 5 opens
N/A
Utility Key Event 10
N/A
KS** Input 10 opens
KS** Input 5 closes
N/A
Utility Key Event 11
N/A
KS** Input 11 opens
KS** Input 6 opens
N/A
Utility Key Event 12
N/A
KS** Input 12 opens
KS** Input 6 closes
N/A
Utility Key Event 13
N/A
KS** Input 13 opens
KS** Input 7 opens
N/A
Utility Key Event 14
N/A
KS** Input 14 opens
KS** Input 7 closes
N/A
Utility Key Event 15
N/A
KS** Input 15 opens
KS** Input 8 opens
N/A
Utility Key Event 16
N/A
KS** Input 16 opens
KS** Input 8 closes
N/A
Utility Key Event 17
N/A
KS** Input 17 opens
KS** Input 9 opens
N/A
Utility Key Event 18
N/A
KS** Input 18 opens
KS** Input 9 closes
N/A
N/A
N/A
Utility Key Event 31
N/A
KS** Input 31 opens
KS** Input 16 opens
N/A
Utility Key Event 32
N/A
KS** Input 32 opens
KS** Input 16 closes
N/A
Utility Key Event 33
N/A
N/A
KS** Input 17 opens
N/A
Utility Key Event 34
N/A
N/A
KS** Input 17 closes
N/A
N/A
N/A
N/A
Utility Key Event 63
N/A
N/A
KS** Input 32 opens
N/A
Utility Key Event 64
N/A
N/A
KS** Input 32 closes
N/A