I

NTRODUCTION

The Voice-Assisted Arm/Disarm Bus Module allows the user to arm
or disarm their security system as well as activate or deactivate  

In

Touch’s

 PGM from any touch-tone telephone. The APR-ADM2

uses detailed voice prompts to guide the user. Due to the Auto-
panel Recognition feature, the 

In Touch

 can be connected to either

the Spectra (V2.0 or higher) or Digiplex control panels.

T

ECHNICAL

 S

PECIFICATIONS

Operating Voltage:

9 - 15VDC

Current Consumption:

Typical: 70mA
Maximum: 105mA (with PGM enabled)

Power Consumption:

1 Watt

PGM Outputs:

1 form “C” relay rated @ 125V, 5A
receptive load

Operating Temperature:

0°C to 50°C (32°F to 122°F)

Compatible Telephone:

DTMF (Touch-tone)

Compatibility:

Any Digiplex control panel

I

NSTALLATION

The APR-ADM2 is connected to Digiplex’s communication bus.
Connect the four terminals labeled “

12

VDC

”, “

GND

”, “

GRN

”, and “

YEL

of the APR-ADM2 to the corresponding terminals of the Digiplex
control panel as shown in Figure 1. Please refer to the Digiplex

Reference & Installation Manual

 for the maximum allowable

installation distance from the control panel.

Connect 

In Touch’s

 “

RING

” terminal to Digiplex’s “

R

1

” terminal and

the “

TIP

” terminal of the 

In Touch

 to the “

T

1

” terminal of the Digiplex

control panel as shown in Figure 1. If the household telephone is
sharing the telephone line with Digiplex and APR-ADM2, connect
the house-hold telephone to the “

R

-1

” and “

T

-1

” terminals of the bus

module as shown in Figure 1.

Connect APR-ADM2’s PGM as shown in Figure 2.

If the control panel is configured to report Arming and
Disarming events and if the 

In Touch

 and control panel

share the same telephone line, the user’s call will be
interrupted during use.

A

UTO

-

PANEL

 R

ECOGNITION

This is a feature that allows 

In Touch

 to be used with either

Spectra or Digiplex. When connected to the bus, the APR-ADM2

will automatically detect which system it is connected to and adjust
its internal communication parameters accordingly. It allows 

In

Touch

 to be connected to any Digiplex control panel as well as any

Spectra control panel V2.0 or higher. 

If connecting the APR-ADM2 to a Spectra control panel, refer to
the 

Spectra APR-ADM2 Reference & Installation Manual

.

P

ROGRAMMING

 M

ETHOD

To access the 

In Touch

 programming mode:

APR-ADM2 can also be programmed using Digiplex’s 

Module

Broadcast

 feature as well as through the WinLoad  Software. Refer

to the 

Digiplex Reference & Installation Manual

 for more

information on the 

Module Broadcast

 feature and to 

WinLoad’s

Online Help

 for information on programming with WinLoad. The

bus module’s serial number can be found on its PC board.

N

UMBER

 

OF

 R

INGS

Section 

[001]

[001]

The value (001 to 255, 000 = disabled) programmed in section

[001]

 represents the number of rings the APR-ADM2 will wait

before picking-up the line. If the line is not answered after the
number of programmed rings, 

In Touch

 will answer the call.

Be sure to program the APR-ADM2 module’s number of
rings to be less than the number of rings programmed in the
Digiplex control panel or enter 

000

 as the number of rings

for the Digiplex.

A

NSWERING

 M

ACHINE

 O

VERRIDE

Section 

[002]

[002]

If the 

In Touch

 uses a telephone line that uses an answering

machine or service, the Answering Machine Override must be
programmed. The value (010 to 255 seconds, 000 = disabled)
programmed in section 

[002]

 represents the delay period that APR-

ADM2 will wait between the first and second call. The user calls the

In Touch

, hangs-up, and then calls back within the value

programmed in section 

[002]

. If the APR-ADM2 is called back

within the programmed delay period, the bus module will override
the answering machine or service by picking-up the line on the first
ring.

PGM T

IMER

Section 

[003]

[003]

When the PGM is activated by a user, the value (001 to 255, 000 =
No Timer) programmed in section 

[003]

 determines the time that

APR-ADM2’s PGM will remain activated. Once the time value set
in section 

[003]

 has elapsed, the PGM will deactivate. If a value of

000 is entered into section 

[003]

, the PGM will remain activated

until it is manually deactivated by the user.

Option 

[4]

 in section 

[004] 

determines whether the PGM

Timer programmed in section 

[003]

 is in seconds or

minutes.

STEP 1: Press and hold the 

[0]

 key

STEP 2: Enter the 

[

INSTALLER

 

CODE

]

 

STEP 3: Enter section 

[953]

 

STEP 4: Enter the APR-ADM2’s 8-digit 

[

SERIAL

 

NUMBER

]

STEP 5: Enter the 3-digit 

[

SECTION

]

 you want to program

STEP 6: Enter the required data