![Paradox DGP2-ZX4 Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/paradox/dgp2-zx4/dgp2-zx4_instructions_3596745001.webp)
4-Zone Hardwire Expansion Module (DGP2-ZX4)
Instructions
DGP2ZX4-EI01
I
NTRODUCTION
The DGP2-ZX4 is a 4-zone expansion module that connects
directly to the Digiplex/DigiplexNE control panel. The DGP2-ZX4
provides four additional hardwired input terminals.
I
NSTALLATION
The DGP2-ZX4 is linked directly to the control panel:
If connecting to a Digiplex (DGP-48)
Connect the DGP2-ZX4’s
Expander Connector
cable to the
Expansion
connector on the control panel as shown in Figure 1.
If connecting to a DigiplexNE (DGP-NE96)
Connect the DGP2-ZX4’s
Expander Connector
cable to the
Zone
Expander
connector on the control panel as shown in Figure 1.
Z
ONE
P
ROGRAMMING
The control panel recognizes the DGP2-ZX4’s inputs as follows:
NO ATZ:
Digiplex
DigiplexNE
DGP2-ZX4 Input 1 =
Input 009
Input 009
DGP2-ZX4 Input 2 =
Input 010
Input 010
DGP2-ZX4 Input 3 =
Input 011
Input 011
DGP2-ZX4 Input 4 =
Input 012
Input 012
ATZ ENABLED:
Digiplex
DigiplexNE
DGP2-ZX4 Input 1 =
Input 009 & 013
Input 009 & 021
DGP2-ZX4 Input 2 =
Input 010 & 014
Input 010 & 022
DGP2-ZX4 Input 3 =
Input 011 & 015
Input 011 & 023
DGP2-ZX4 Input 4 =
Input 012 & 016
Input 012 & 024