DESCRIPTIONS
The SSL-SMOKE detector is a device, which connects with
SSL-EMD. When smoke is detected an alarm will sound
alerting the users. Through the SNMP-SSL card, the user can
monitor it and receive notifications of the alarms.
This
type of
AC/DC
smoke detec
tor can be powered by 120VAC utility
power or
a 9-volt battery. AC/DC smoke detectors offer added
protection in the event of a power failure or a dead battery.
INSTALLATION
1. Detach the cover by twisting it until it unlatches from the
smoke detector base.
2. Using the smoke detector base as pattern, trace outlines of
the two keyhole slots onto the mounting surface.
3. Drill a pilot hole in the center of the small end of each of the
keyhole slots in the mounting surface.
4. Insert and tighten the mounting screws in the pilot holes
leaving approximately 1/8” of the screws sticking out.
5. Mount the smoke detector base making sure that screws
are positioned in the small ends of the keyholes and tighten
the screws.
6. Snap on the battery wire clip and insert the battery into
battery holder.
7. Replace the cover by twisting it until it latches. The smoke
detector is now operating.
8. Test the smoke detector by pushing test button on cover
and holding the button down for about 2-seconds.
Use the following steps to set-up and connect the
SSL-SMOKE detector to the SSL-EMD:
1. Loosen the screws on SSL-EMD.
2. Connect the wires from the SSL-SMOKE detector to the
SSL-EMD Alarm-1 and/or Alarm-2, and then tighten the screws.
3. Connect the straight-through CAT5 network cable from the
SNMP-SSL card’s RJ45 connector labeled “COM” to the
connector labeled “010101” on the SSL-EMD.
4. Verify that the SNMP-SSL card has a network connection and
is powered on.
5. Check the LED (Power/Status) of SSL-EMD, it will flash every
5-seconds.
6. Open a Web browser and connect to the SNMP-SSL card.
7. Change the setting of “SSL-EMD Status” from “Disable” to
“Auto” on the EMD Configuration page.
8. Set the status of Alarm-1 and/or Alarm-2 to “Normal Open”.
9. The installation of the SSL-SMOKE detector is complete. See
the SNMP-SSL User’s Manual.
Note:
The SSL-SMOKE detector operates with 120VAC or a
9-volt battery. Connecting to the 120VAC utility power is not
required to operate the detector. However, operating with both
the utility power and the battery offers added protection in the
event of a power failure or a dead battery.
LIMITED PRODUCT WARRANTY
Para Systems Inc. (Para Systems) warrants this equipment, when
properly applied and operated within specified conditions, against
faulty materials or workmanship for a period of three years from the
date of original purchase by the end user. For equipment sites within
the United States and Canada, this warranty covers repair or
replacement of defective equipment at the discretion of Para Systems.
Repair will be from the nearest authorized service center.
Replacement parts and warranty labor will be borne by Para Systems.
For equipment located outside of the United States and Canada, Para
Systems only covers faulty parts. Para Systems products repaired or
replaced pursuant to this warranty shall be warranted for the remaining
portion of the warranty that applies to the original product. This
warranty applies only to the original purchaser who must have properly
registered the product within 10 days of purchase.
The warranty shall be void if (a) the equipment is damaged by the
customer, is improperly used, is subjected to an adverse operating
environment, or is operated outside the limits of its electrical
specifications; (b) the equipment is repaired or modified by anyone
other than Para Systems or Para Systems-approved personnel; or (c)
has been used in a manner contrary to the product's operating manual
or other written instructions.
Any technical advice furnished before or after delivery in regard to use
or application of Para Systems’s equipment is furnished without charge
and on the basis that it represents Para Systems’s best judgment
under the circumstances, but it is used at the recipient's sole risk.
EXCEPT AS PROVIDED HEREIN, PARA SYSTEMS MAKES NO
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE.
Some states do not permit limitation of
implied warranties; therefore, the aforesaid limitation(s) may not apply
to the purchaser.
EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL PARA
SYSTEMS BE LIABLE FOR DIRECT, INDIRECT, SPECIAL,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF
THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Specifically, Para Systems is not
liable for any costs, such as lost profits or revenue, loss of equipment,
loss of use of equipment, loss of software, loss of data, cost of
substitutes, claims by third parties, or otherwise. The sole and
exclusive remedy for breach of any warranty, expressed or implied,
concerning Para Systems’s products and the only obligation of Para
Systems hereunder, shall be the repair or replacement of defective
equipment, components, or parts; or, at Para Systems’s option, refund
of the purchase price or substitution with an equivalent replacement
product. This warranty gives you specific legal rights and you may
also have other rights, which vary from state to state.
OBTAINING TECHNICAL ASSISTANCE
Para Systems (Minuteman UPS) Technical Support:
Phone: 1-972-446-7363
Fax: 1-972-446-9011
Web: www.minutemanups.com/support/con_tech2.php
www.minutemanups.com ©
Copyright 2008
34000363
R1