background image

Remote Logger Unit User Manual

-

8

-

Reset Button

The back of the RLU includes a

Reset

button, which allows the user to reboot the unit.

Connections

On the rear of the RLU are several connectors:

l

Power Monitoring

: PDUs connect here

l

Inputs

: Probes are connected here

l

Serial Port

: For connection of a smart meter or serial terminal

l

USB

: For connection of a USB device such as a serial terminal

l

GSM

: For connection of a GSM aerial

Содержание SmartZone EPA126

Страница 1: ...Release 1 0 Issue 1 0 Remote Logger Unit User Manual...

Страница 2: ...photocopying recording or otherwise without written permission from Panduit No patent liability is assumed with respect to the use of the information contained herein Although every precaution has bee...

Страница 3: ...rning Statements 9 Rack Mount the RLU 10 Initial Setup 11 Installation Requirements 11 Connection to Configuration Interface 11 Default Network Settings 12 Initial Network Setup 12 Network Server Setu...

Страница 4: ...Remote Logger Unit User Manual 4 Appendix A Technical Details 20 Factory Default Settings 20 Operating Information 20...

Страница 5: ...f monitor data Environment Monitoring The Remote Logger Unit has the capability to monitor temperature humidity air pres sure and speed luminous intensity contact state and pulse count and to raise al...

Страница 6: ...be pressed together Information of note may be presented like this Warning These messages alert you to specific procedures or practices serious con sequences including injury may result if you disreg...

Страница 7: ...anel of the Remote Logger Unit Rear of RLU The following image shows the rear panel of the Remote Logger Unit LEDs LEDs can be found on the rear of the RLU Their purpose is described below l Power Ill...

Страница 8: ...o reboot the unit Connections On the rear of the RLU are several connectors l Power Monitoring PDUs connect here l Inputs Probes are connected here l Serial Port For connection of a smart meter or ser...

Страница 9: ...RLU does not exceed 90 Relative Humidity Installation Warning Statements This section includes the basic warning statements l Only trained and qualified personnel should be allowed to install replace...

Страница 10: ...ounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit use of a power strip etc Rack Mount the RLU Hold th...

Страница 11: ...nterface accessible via the RS232 and USB ports For the RS232 connection a lead will be needed as follows Function RLU Dir PC RTS 6 way RJ45 1 8 9 way D female Rx 2 3 Gnd 3 5 CTS 4 7 Tx 5 2 3 3V 6 For...

Страница 12: ...the current configuration enter CONFIG filter where the filter is the first letters of a set of commands CONFIG has two aliases and CFG If the ID of the required network isn t present the configuratio...

Страница 13: ...ading to the power meter and probe monitoring information is periodically stored on the RLU The logging times are configured as follows l LI interval sets the interval in seconds between successive lo...

Страница 14: ...nits if relevant otherwise this value is set to 0 ID Power Meter Type 0 None 1 UTL PDU Single Phase 2 UTL PDU 48V DC 3 UTL PDU Three Phase 4 ND Multi Cube 5 ND 350 To read back a configuration record...

Страница 15: ...order Alarms are enabled by default when configured but their enable status may be con trolled as follows PWR ALARMEN id s1le s1he snle snhe Alarm levels and the enable state for a particular meter c...

Страница 16: ...ult use env template id 0 To read back the names of all active templates use env template Analog Probes The types of analog sensors are l Temperature l Humidity l Luminous Intensity l Air Pressure l A...

Страница 17: ...nid pnlt pnht Values apply to all probe types including digital regardless of measurement units Port configurations do not have to be in any particular order Alarms are enabled by default when configu...

Страница 18: ...downloaded and installed and the system restarted Note The system will always attempt to update the firmware if it finds a valid update file on the server that is different from the one currently bein...

Страница 19: ...ack side of unit the side with the con nectors 1 Press and release the Reset button This starts the reboot process 2 The green Status light will illuminate and then extinguish and the red Alarm light...

Страница 20: ...gement Address http 192 168 0 253 Default Username admin Default Password admin Operating Information Input Power 100 240 VAC 45W 50 60 Hz Operating Temperature 0OC to 40 OC Storage Temperature 10 OC...

Отзывы: