© Panduit Corp. 2018
OPERATION MANUAL
CT-930LPCH &
CT-940CH/BJO
CT-930LPCH_CT-940CH/BJO: PA29199A01_00
Page: 6 of 9
6-2018
FIG. 2
CD-940 SERIES DIES
DIE INSTALLATION
CAUTION:
DO NOT
operate tool without dies installed.
1.
Select the appropriate dies to match the compression connector to be crimped.
2.
Align one of the die halves in the die cavity contour in the tool head or ram. While depressing the
die release buttons, slide the die half so it is seated in the die cavity. Release the die release
buttons and check to ensure the die is locked into place. Repeat procedure with second die half.
FIG. 3 CT-930LPCH LOW PRESSURE CRIMP HEAD