background image

INSTRUCTIONS CM340B

For Technical Support: www.panduit.com/resources/install_maintain.asp

Page 6 of 28

Shipping Bracket Removal

There are two (2) bracket used for shipment of the Front door and four(4) brackets for shipment of side panels. Remove brackets prior to use of 
the cabinet see below.

Side Panel Brackets

Door Brackets

Содержание CM340B

Страница 1: ...STOP READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING SERVER CABINETFROM SKID CM340B ...

Страница 2: ... Bezel and Removable Cover Kit 1 Hardware Kit 1 Base Cabinet 1 Single Hinge Door 1 Split Door Set 1 Vertical Blanking Panel Set 1 Cable Management Finger Kit 1 POU Bracket Kit 1 Bezel and Removable Cover Kit 1 Hardware Kit Page 2 of 28 CS3 1 Base Cabinet 1 Vertical Blanking Panel Set 1 Cable Management Finger Kit 1 POU Bracket Kit 1 Bezel and Removable Cover Kit 1 Hardware Kit Other cabinet config...

Страница 3: ...t Removal 6 Caster Kit CNCSTR 7 Leveling 8 Floor Mounting 9 J Hook Removal 10 Ganging 11 Vertical Blanking Panels 12 13 Equipment Rails 14 15 Grounding 16 Power Outlet Unit POU Mounting Brackets 17 19 Single Hinge Door 20 22 Fascia 23 Door Adjustment 24 Split Doors 25 Side Panels 26 27 Overhead Cable Openings 28 Cable Management 28 NOTE Some views in this document may vary slightly from your cabin...

Страница 4: ... Guide Caster Kit CNCSTR Finger Kit CNBRFK Page 4 of 28 Cabinet Rails Cage Nuts CNRC Server Cabinet Extended Front Cage Nut Rails CSRCE Single Hinge Door CNDSH Power Outlet Unit Bracket Kit CVPDUB Vertical Blanking Panel Kit CSVBP Cabinet Accessory Bracket CVPPB Dual Hinging Door CNDDE Solid Side Panel CNPS Split Doors CNDS ...

Страница 5: ...Pallet Bolt Locations Base Cabinet Before removal of packaging material Check tip indicator on the outside of cabinet to ensure cabinet was shipped in the upright position Note Doors and Side panels are removed for clarity See pages 20 thru 25 for door installation removal and pages 26 and 27 for side panel installation removal J Hooks IMPORTANT Leveling Legs must be fully retracted before the cab...

Страница 6: ...sources install_maintain asp Page 6 of 28 Shipping Bracket Removal There are two 2 bracket used for shipment of the Front door and four 4 brackets for shipment of side panels Remove brackets prior to use of the cabinet see below Side Panel Brackets Door Brackets ...

Страница 7: ...ided as shown using a 1 2 13mm socket Retract the leveling legs to allow the cabinet weight to be sup ported by the casters Note Casters can support a fully loaded cabinet However the casters should only be used to move the cabinet from one location to another To ensure maximum stability the leveling legs should be used to support the cabinet when it is in its permanent location Mounting Hook Torq...

Страница 8: ...on the base rails in the locations shown to adjust legs until the cabinet is level For ganged cabinet applications ensure that adjacent cabinets are adjusted to the same height parallel with each other and no gaps at the top or bottom between cabinets 3 8 socket Note The maximum weight load of the cabinet is 2500 pounds 1134 kg The weight load should be evenly distributed across the height of the ...

Страница 9: ...an anchor the leveling feet on access floor and slab installations or anchor the frame without leveling feet directly to the concrete slab Assembly Sequence 1 Install the floor anchors from inside the cabinet frame capturing each of the four leveling feet 2 Attach the anchors to the floor with appropriate hardware for your type of floor Note If not using the anchoring brackets use four 4 bolts to ...

Страница 10: ...binet For ganged cabinet applications the J Hooks can be removed to provide greater access between cabinets The J Hooks can be removed by removing the two screws mounted to the cabinet post Note The J Hook with the door catch mounted on it must stay on the cabinet for the single hinge door to operate Important If J Hooks are not wanted they should be removed before ganging cabinets Screws Vertical...

Страница 11: ...r operation 12 24 Trilobular Screw Bottom Ganging Bracket Bottom Mounting Location Screw intended for second cabinet Base portion of two ganged cabinets has been removed for clarity Ensure the door shoes of adjacent cabinet are touching Secure the bottom of the cabinets with two 2 bottom ganging brackets and four 4 12 24 tri lobular screws in the locations shown Secure the top of the cabinets with...

Страница 12: ...seal on blank of opposite vertical blanking panel NOTE Views below show door catch installed for right side handle orientation of door Reverse steps when single hinge door is configured for left side handle orientation Insert 2 1 cap plugs into floor mounting access holes of bottom horizontal blanking panel as shown at the bottom of this page Flap Seal Door Catch Blank shown in dashed outline CUT ...

Страница 13: ... offset flange facing in towards the cabinet Loosely Mount six 6 6 32 screws through adjacent vertical blanking panel to clip nuts as shown Adjust location of clip nuts if needed Before tightening any blanking panel mounting hardware ensure that all blanking panel components are not strained and the mounting distance between equipment rails is EIA spaced 18 31 Tighten 12 24 screws to torque of min...

Страница 14: ... Adjustment and Usage The rear rails are fully adjustable To change depth loosen three 3 5 16 x 3 4 mounting bolts using a 1 2 13mm socket and slide to desired position Retighten the mounting bolts to 14ft lbs 19 0 N m Proper torque ensures equipment rails are bonded to the cabinet frame 5 16 Bolt 5 16 Bolt 5 16 Bolt ...

Страница 15: ...ree locations shown below with Bolt and Dual Nut provided The Paint Piercing washers are used in the middle location to bond the equipment rails to the cabinet as shown in figure 1 Note Torque bolts to 14 ft lbs 19 0 N m to ensure equipment rails are bonded to the cabinet frame Figure 1 Thread bolt through hole toward outside of cabinet Paint piercing washer ...

Страница 16: ... asp Page 16 of 28 Grounding The Grounding locations for connection to the CBN Common Bonding Network are shown below Remove masking from desired grounding location Use PANDUIT RGEJ series equipment jumper CBN connection Grounding Bar Location PANDUIT RGRB series Grounding Lug Location ...

Страница 17: ...17 of 28 36 75 BUTTON SPACING 49 0 BUTTON SPACING 64 75 BUTTON SPACING Power Outlet Unit POU Mounting Bracket Locations for Typical Tool less Mounting Button Spacing 64 75 Button Spacing 36 75 Button Spacing 49 0 Button Spacing Positioning Hole Positioning Hole Positioning Hole Positioning Hole ...

Страница 18: ...llation instructions 12 24 Positioning Screw Bottom center slot of bracket rests on positioning screw 49 0 BUTTON SPACING 36 75 BUTTON SPACING 64 75 BUTTON SPACING 12 24 Positioning Screw Bottom center slot of bracket rests on positioning screw 12 24 Positioning Screw Top center slot of bracket rests on positioning screw 12 24 Positioning Screw Bracket is adjusted so that posi tioning screw is at ...

Страница 19: ...ighten screws to 45 in lb 5 in lb Refer to Pages 17 and 18 for hole and slot orientation Install buttons of Power Outlet Unit POU into CVPDUB bracket as shown Power Outlet Unit POU Mounting Bracket Installation non typical button spacing If POU does not employ typical button spacing mount top bracket first to locate POU Mount lower bracket in appropriate position utilizing bonus holes CVPDUB Insta...

Страница 20: ...oor support Swinging door up pull down the lever of the spring loaded hinge pin and align pin with the bushing in the top cap Release lever when aligned To remove the doors reverse steps Note Make sure that the top pin is fully engaged when installed Upper Hinge Location Lower Hinge Location Note For cleaning PANDUIT recommends using SIMPLE GREEN all purpose cleaner or local equivalent and a lint ...

Страница 21: ...ng Spring Hinge Pin Door Header Spring Hinge Pin Finger Handle 1 4 20 Screw Single Hinge Door Hinge Direction Reversal Remove the two 2 hinge pins as shown in the figure below Reinstall on the opposite corner by reversing the steps below Remove door handle and filler plates See next page for door handle removal instructions ...

Страница 22: ...door Rotate Cam Stop 90 degrees counterclockwise Rotate Cam 180 degrees counterclockwise Reinstall Screw Reinstall latch and filler plates as shown below Remove two bolts shown below with a 3 8 socket and reinstall bracket on opposite side Bolts Bracket Cam Cam Stop Remove Door Handle Screw Remove Screw Cam and Cam Stop Cam Stop Cam Depress two 2 spring loaded tabs to remove handle from Single Hin...

Страница 23: ... 23 of 28 Fascia Installation Remove the three 3 keyed knockouts and secure the fascia with the three 3 screws provided The screws are thread cutting and will tap into the mounting holes of the plastic fascia IMPORTANT Note Do not over tighten Maximum torque applied should be 20 in lbs 2 26 N m ...

Страница 24: ...ing allows field adjustments on the cabinet doors Loosing the set screw and raising the lift screw which lifts the door adjusting the door s fit within a cabinet s door frame Dual hinge door Split Doors Network Cabinet Dual hinge door Exploded View Lift Screw Bushing Set Screw Door adjusted by lift bushing maintaining consistent top gaps Corrected door fit by adjusting opposite side lift screw Re ...

Страница 25: ...ing door up pull down the lever of the spring loaded hinge pin and align pin with the bushing in the top cap Release lever when aligned To remove the doors reverse steps Note Split doors are bonded to the cabinet through the door hinge pin and bottom bushing Note For cleaning PANDUIT recommends using SIMPLE GREEN all purpose cleaner or local equivalent and a lint free cloth Bushing Fixed Hinge Pin...

Страница 26: ...o the cabinet frame Install side panel as shown on the next page Spring Clip Lower Center Support Bracket Support Tube Assembly External Tooth Lock Washer 12 24 Screw External Tooth Lock Washer Install the bottom tube support bar assembly using four 4 12 24 screws and two 2 12 external tooth lock washers as shown Adjust assembly as needed to fit side panel squarely in place with cabinet opening Ch...

Страница 27: ...sed between cabinets install if needed prior to ganging cabinets If switch air ducting CNAE series will be used with side panels between ganged cabinets install both ducting and side panels prior to ganging Note The side panel is bonded the cabinet at the interface between the spring clips on the top cap and the side panel masked area If a side panel is moved to a different cabinet the masking sho...

Страница 28: ...w proper alignment with rack units Removable Cover Overhead Cable Opening Bezel Overhead Cable Opening Bezel INSTALLED Center Top Plate Overhead Cable Openings Cabinet is equipped with multiple covers and knockouts for cable entry The center top plate can be removed by removing the four 4 12 24 screws that hold it in place Knockouts can be removed by cutting the 8 tabs with a wire cutter as shown ...

Отзывы: