![Panduit Atlona Omega AT-OME-PS62 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/panduit/atlona-omega-at-ome-ps62/atlona-omega-at-ome-ps62_instructions-manual_3530194016.webp)
AT-OME-PS62
16
Front Panel Operation
The AT-OME-PS62 front panel provides a way to quickly view current settings, set up routing, load/save EDIDs, and
save/recall current I/O routing. This will provide basic settings for use, view the webGUI section for more advanced
set up and routing.
When turned on, the front panel will display initializing until the unit is fully powered and functional. After initial start
up, the front panel will display the home screen.
For navigating through the front panel options and routing, the MENU, ENTER, up, down, and number keys will be
used.
Routing
NOTE:
After 30 seconds of inactivity, the front panel LCD will turn off. Press any button to activate the
LCD again.
ENTER
1
4
2
3
5
6
MENU
Basic
ALL
Basic routing can be done when the PS62 is in matrix mode.
All will route the selected input to all outputs.
1.
Select the first input number and press enter. This will set the input for output 1.
2. Select the second input number and press enter. This will set the input for output 2.
1. Select the
MENU
button.
2. Use the
^
and buttons to go through the menu options until the screen reads Route Setting.
3.
Press Enter. The new screen should say Route All.
4.
Press Enter again. The new screen will provide input options.
5. Select the input number to route to the outputs and press enter.
^