background image

AT-UHD-CAT-4ED

16

Device Operation

Selecting EDID 

Presets

The AT-UHD-CAT-4ED comes with a default EDID plus 16 pre-programmed EDID selections.  When selecting the 

default or one of the pre-programmed EDID selections, the EDID mode must be set to 

INT

 (internal) mode. 

Available EDID selections are presented in the table below.

1.  Login to the web server.  Refer to 

Introduction to the Web Server (page 29)

 for more information.

2.  Click 

EDID

 in the menu bar.

3.  Make sure the 

EDID lock

 toggle switch is set to 

UNLOCK

.

4.  Click the 

EDID mode

 drop-down list and select 

INT

.

5.  Select the desired EDID from the 

INT EDID settings

 drop-down list. 

The selected EDID will be used by the source, before sending A/V data to the display (sink) device.

NOTE:  

If the resolution and timing limitations of all displays, connected to the 

HDBaseT OUT

 ports, 

are unknown, then select the 

STD

 EDID for the best compatibility.  The 

STD

 EDID will automatically 

build an EDID based on the capabilities of all connected displays.  When selecting an EDID, make 

sure all connected displays can support the resolution and timing information.  Otherwise, loss of 

picture and/or audio may result.

EDID

STD

ATL 1280x800 RGB 2CH

ATL 1080P 2CH

ATL 1366x768 RGB 2CH

ATL 1080P Multi CH

ATL 1080P DVI

ATL 1080P DD

ATL 1280x800 RGB DVI

ATL 1080P 3D 2CH

ATL 3840x2160@30 2CH

ATL 1080P 3D Multi CH

ATL 3840x2160@30 Multi CH

ATL 1080P 3D DD

ATL 3840x2160@60 2CH

ATL 720P 2CH

ATL 3840x2160@60 Multi CH

ATL 720P DD

Содержание ATLONA AT-HDR-CAT-4EDLA

Страница 1: ...AtlonaManuals DistributionAmplifiers AT UHD CAT 4ED HDMI to HDBaseT Distribution Amplifier 4K UHD TM...

Страница 2: ...ion Release Date Notes 1 Mar 2019 New format 2 Mar 2021 Included instructions for Updating the Valens Firmware page 39 3 Apr 2022 Corrected wiring instructions for IR control of source and sink device...

Страница 3: ...rive San Jose CA 95134 United States Office 1 408 962 0515 Sales and Customer Service Hours Monday Friday 6 00 a m 4 30 p m PST https atlona com International Headquarters Atlona International AG To d...

Страница 4: ...the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equ...

Страница 5: ...ecting EDID Presets 16 Managing Users 17 Adding Users 17 Editing Deleting Users 18 RS 232 Control 19 Determining the Port Type 19 Cable Assembly 20 Pass through mode 21 Control mode 22 IR Control 23 C...

Страница 6: ...hannel audio compliant EDID management Intuitive GUI based configuration using integrated web server TCP IP RS 232 and IR control Easy to configure and manage with AMS Atlona Management System Field u...

Страница 7: ...control system to this port to control the AT UHD CAT 4ED 12 RS 232 IR 1 4 Connect a control system or other DTE device to these ports for pass through zone control Each of these ports uses the associ...

Страница 8: ...ports is associated to the respective HDBaseT OUT port This allows RS 232 pass through zone control of a display sink device that is connected to a PoE compatible receiver Control can be performed us...

Страница 9: ...isplay Display Display Display H D M I PO WE R LIN K FW AT UH D E X 7 0C RX AT UHD EX 70C RX H D M I PO WE R LIN K FW AT UH D E X 7 0C RX AT UHD EX 70C RX H D M I PO WE R LIN K FW AT UH D E X 7 0C RX...

Страница 10: ...ss and hold the POWER button for approximately 15 seconds Release the POWER button once the LOCK LED indicator begins to flash The number of flashes will indicate the currently selected IP mode Settin...

Страница 11: ...by the DHCP server if present The System page page 35 in the web server allows the AT UHD CAT 4ED to use either DHCP or static IP mode In order to access the web server the IP address of the AT UHD C...

Страница 12: ...e sure a secure connection exists between the HDMI port on the AT UHD CAT 4ED and the source display device Try a different HDMI cable HDBaseT 1 4 Blue Normal operation Signal integrity between the AT...

Страница 13: ...for five seconds then release The LOCK LED indicator will no longer be illuminated Using the Front Panel Using the web server TX TX RX RX 4 3 2 4 3 2 1 1 RS 232 MASTER IN OUT LAN HDMI HDBaseT OUT DC 4...

Страница 14: ...splay sink device Make sure that the sink device is powered Learning an EDID using the Front Panel HDBaseT OUT 1 HDMI Display AT UHD CAT 4ED AT UHD EX 100CE RX 4 3 2 1 OUT IN HDM I HDB aseT LOC K EDID...

Страница 15: ...o switch between LOCK and UNLOCK states 4 Click the EDID mode drop down list and select LEARN 5 Click the COPY button to copy the downstream EDID to memory The AT UHD CAT 4ED will now use the EDID of...

Страница 16: ...t The selected EDID will be used by the source before sending A V data to the display sink device NOTE If the resolution and timing limitations of all displays connected to the HDBaseT OUT ports are u...

Страница 17: ...tory default username and password for the admin user are listed below Username root Password Atlona 3 Click the Config tab 4 Click the Add button under the Edit column 5 Enter the desired username an...

Страница 18: ...Atlona a Click Config in the menu bar b Click the Edit button next to the user to be changed c Enter the new information for the user in the Username Password Edit dialog box d Click the Save Change...

Страница 19: ...ot always the case If the port type is unknown then a multimeter can be used to determine whether the port is DTE or DCE Determining the Port Type 1 Turn on the multimeter and set it to measure DC vol...

Страница 20: ...the TxD RxD and GND wires Cable Assembly When connecting a DTE device to a DCE device a straight through cable should be used A straight through cable is wired in such a way that the pins on one side...

Страница 21: ...RX TX 1 Connect the RS 232 cable from the control system to the desired RS 232 IR port on the AT UHD CAT 4ED Refer to Cable Assembly page 20 for instructions on preparing the cable 2 Connect an Ethern...

Страница 22: ...COM NC NO 12V SIG GND 12V SIG GND 12V SIG GND 12V SIG GND 1 COM PON ENT HDM I 1 2 3 4 5 6 SER IAL 1 IR OUT SER IAL 2 L R DIGI TAL COA X OUT AUD IO OUT AUD IO IN ETH ERN ET 2 3 4 VIDE O OUT 48V DC FAC...

Страница 23: ...ect the GND terminal from the AT UHD CAT 4ED to the GND terminal on the control system 4 3 2 1 OUT IN HDMI HDBaseT LOCK EDID POWER INT LEARN TX RX 4 3 2 4 3 2 1 1 STER UT HDBaseT OUT DC 48V IR FW TX T...

Страница 24: ...e but do not overtighten 5 Connect the captive screw connector to the RS 232 IR IN port of the zone to be controlled Controlling Source Devices IR Emitter RS 232 IR 1 HDBaseT HDBaseT OUT 1 IR Receiver...

Страница 25: ...button will be blue Pressing the POWER button again will place the unit into standby mode and the POWER button will be red In standby mode no video signal will pass to the display sink device However...

Страница 26: ...Web Server page 29 for more information The factory default username and password are listed below Username root Password Atlona 4 Click System in the menu bar 5 Click the Power button mode drop down...

Страница 27: ...CEC power on and power off commands by pressing the ON and OFF buttons near the bottom of the page 7 Press the POWER button on the front panel to power on or power off the display Note that the power...

Страница 28: ...he POWER button on the front panel to power on or power off both the display and AT UHD CAT 4ED Consumer Electronics Control CEC Atlona has confirmed proper CEC functionality with several current mode...

Страница 29: ...refer to IP Configuration page 10 The default static IP address of the AT UHD CAT 4ED is 192 168 1 254 Introduction to the Web Server 1 Launch a web browser 2 In the address bar type the IP address o...

Страница 30: ...AT UHD CAT 4ED 30 The Web Server 7 The Info page will be displayed 8 Click Logout on the far right side of the menu bar to log out of the web server and return to the Login page...

Страница 31: ...of firmware that the AT UHD CAT 4ED is running Always make sure to check the AT UHD CAT 4ED product page on the Atlona web site for the latest version of firmware Output 1 VALENS Version Output 4 VAL...

Страница 32: ...200 38400 56000 57600 115200 Data bit Sets the number of data bits used to represent each character of data The following options are available 7 or 8 Parity Sets the parity bit which can be included...

Страница 33: ...ed source device to determine what video and audio formats can be sent to the sink device Refer to EDID Management page 14 for more information INT EDID settings Click this drop down list to select th...

Страница 34: ...Password Enter the new password for the root username in this field Confirm New Password Verify the new password by retyping it in this field All User Login Settings Username Displays the username Pas...

Страница 35: ...e Click this toggle to set the login mode to either ON or OFF If this feature is set to ON then the AT UHD CAT 4ED will prompt for both the username and password at the start of a Telnet session Use t...

Страница 36: ...l Power on and power off commands are sent over both the HDBaseT OUT and HDMI OUT ports Reset to Default Click the Factory Default button to set the AT UHD CAT 4ED to factory default settings Firmware...

Страница 37: ...cable from the computer containing the firmware to the same network where the AT UHD CAT 4ED is connected 2 Go to the System page page 35 in the web server Appendix 3 Click the Choose File button und...

Страница 38: ...USB A to USB mini B cable between the PC and the firmware port on the AT UHD CAT 4ED 5 The USB UPDATE folder will be displayed If this folder is not displayed automatically select the USB UPDATE drive...

Страница 39: ...nect an Ethernet cable from the computer containing the firmware to the same network where the AT UHD CAT 4ED is connected 2 Go to the System page page 35 in the web server 3 Click the Choose File but...

Страница 40: ...ect the USB A to USB mini B cable between the PC and the firmware port on the AT UHD CAT 4ED 5 The USB UPDATE folder will be displayed If this folder is not displayed automatically select the USB UPDA...

Страница 41: ...for recommended cabling when using Altona products with HDBaseT The green bars indicate the signal quality when using each type of cable Higher quality signals are represented by more bars EIA TIA 568...

Страница 42: ...t Parity Stop bit 115200 8 None 1 EDID EDID lock EDID mode INT EDID settings UNLOCK INT STD Config Username default Password default root Atlona System IP Mode Static IP Address default Netmask Gatewa...

Страница 43: ...Hz 1152 870 75 Hz 1024 768 60 Hz 848x480 60 Hz 800 600 60 Hz 640 480 60 Hz Color Space YUV RGB Chroma Subsampling 4 4 4 4 2 2 4 2 0 Color Depth 8 bit 10 bit 12 bit Audio HDMI HDBaseT Pass Through For...

Страница 44: ...W 1 x Mini USB DC 48V 1 x 3 pin DIN Environmental Fahrenheit Celsius Operating Temperature 32 to 122 0 to 50 Storage Temperature 4 to 140 20 to 60 Operating Humidity RH 20 to 90 non condensing Power C...

Страница 45: ...US International atlona com 408 962 0515 41 43 508 4321 35230 R5...