14
Before any regulations it is necessary to
disconnect the product from the mains.
Upon
regulation
or
preliminary
regulation
completion, the technician shall restore the seals.
Gas rings of our production don’t require
regulation of primary air.
9) TAPS
“Minimum” Position Regulation
- Turn on the gas ring and install the control knob in
“Minimum” position (low flame, Fig. 1).
-
Remove control knob “M” (Fig. 14 - 14/A), which is
put on the tap pin.
- Point for minimum supply setting can be arranged as
follows: on the side of the tap (Fig. 14) or in the
bottom part of the strip. In any case, regulation is
performed by entering the small screwdriver “D” into
hole near the tap (Fig. 14), or into hole “C” inside the
gas supply tap (Fig. 14/A).
- Turn the screwdriver to the right or to the left from the
setup point in order to regulate the flame according
to the restricted supply position.
Tap Lubrication
If the tap doesn’t turn, don’t
apply force, call for technical
assistance.
FIG. 14
It is supposed that this regulation can be
performed only for gas rings, which are installed
on G20, for gas rings, which are installed on G30
or G31, the screw shall be tightened to stop
(clockwise).
- For
DUAL
gas ring the regulation screw is located
inside the pin of bypass cock, which control the
central flame line, moreover, the screw is located on
the side and controls the external flame line.
The above described operations can be performed
conveniently regardless of position or method, with
which the cooktop is attached to the furniture.
GAS RINGS DON’T REQUIRE ANY REGULATION
OF PRIMARY AIR.
WARNING:
Before starting regulation of minimum position
for DUAL gas ring, remove bushing “E” (Fig. 14).
For
DUAL
gas ring the regulation screw is located
inside the pin of bypass cock, which control the
central flame line, moreover, the screw is located on
the side and controls the external flame line.
FIG. 14/A
REGULATION