4. ELECTRICAL CONNECTION (Only to be done by qualified professionals)
The power for the cable that you must use with the hood must be
single phase, Neutral, Line and
Earth, 220-240vAC 50-60Hz.
ATTENTION! During installation and subsequently, when
carrying out any operation inside the hood or during
maintenance, make sure the appliance is disconnected
from the mains.
The electrical power supply must be stable and meeting the electrical requirements of the appliance (see the
nameplate of the appliance).
The hood must be connected to the mains supply with an independent line to the electric panel so as to avoid
interference in the hood caused by fluorescent lamps or other devices that transmit noise to the mains.
Make sure the mains plug of the appliance is accessible or if not, install a switch in compliance with electrical
regulations.
If the hood does not have a power cable with a plug, or other means to disconnect it from the mains with a
separation between the poles, and with means to disconnect completely under category III overvoltage
conditions, it must be fitted with means to disconnect it from the mains in case of category III overvoltage
conditions (Multi-pole disconnection switch connected directly to the power terminals, with a separation
between the poles to interrupt electrical supply in the case of category III overvoltage).
If the power cable is damaged, it must be replaced by the manufacturer, your after-sales service or qualified
personnel, to avoid hazards.
Make sure you do not disconnect or cut any wires inside the hood, if this were to happen, contact the nearest
after-sales service. Request the aid of a qualified technician for electrical connection.
This must be done in compliance with current regulations.
If the specifications label inside the hood displays this symbol
: the appliance is class II. In which case it
does not need an earth connection.
If the specifications label inside the hood DOES NOT display this symbol
: the appliance is class I. In this
case it NEEDS an earth connection.
The cable
connecting the hood and the motor in “Exterior Motor” models should have a minimum section of
3 x 1 mm.
The cable connecting the hood and the motor in “Roof Motor” models will be of HO7RN-F class and
characteristics with a 3 x 1mm section (up to 5 metres in length.) and 3 x 2.5 mm (up to 25 metres in length).
The extractor hood must “always” be connected to an installation with a good “earth”. Pando will accept no
responsibility if these instructions are not followed (except in Class II appliances, indicated with this symbol
).
Key for power cables:
1:
Brown or black = Line / Phase
(L)
2:
Blue = Neutral
(N)
3:
Green / Yellow = Earth