54
24
4.4- Warning messages and alarms (SMARTCLORO PLUS PH)
In the event of abnormal operati on, the SMART series equipment will display an alarm message on the
4th line of the screen, together with an acousti c warning. The alarms shutdown the equipment unti l
the problem is solved. Similarly, it will display a warning also in the 4th line, but without an acousti c
signal or shutti ng down the equipment. In this case, the equipment can conti nue operati ng, although
you are informed that correcti ve acti on should be taken.
4.3.1- Warnings
Message:
Causes:
Acti on required:
“LACK OF SALT”
Lack of salt in the water
Add salt to the swimming pool
Incrustati ons or objects in the electrolysis cell
causing excess current
Clean the cell
The electrolysis cell is worn
Replace the electrolysis cell with a new
one
“EXCESS SALT”
Excess salt in the water
No acti on required if excess is not very
signifi cant
Incrustati ons or objects in the electrolysis cell
causing excess current
Clean the cell
“NO WATER FLOW”
Excess gas in the electrolysis cell. It may be
because the pump has shutdown. The gas is
hydrogen gas which is highly fl ammable
The piping should be drained to
eliminate gas or accumulated water.
Check the pump
Sensor cable of the cell is incorrectly connected or
broken
Check the sensor cable (white cable)
Cell sensor is dirty
Clean. See maintenance
No water fl ow
Check the water system
“OVERLOAD”
The cell is incorrectly connected
Check wiring
Metal body in the cell
Turn off the equipment and remove the
metal body from the sheets
The 4 producti on LEDs (%) will
fl ash. (Open circuit)
Cell is incorrectly connected
Check the cell connecti on and ensure
that cables and connecti on terminals are
in good conditi on
Cell is damaged or completely worn down
Check the conditi on of the cell
electrodes, and replace it if any damage
is observed
Swimming pool water with very low salt
concentrati on
Ensure that the water has salt and that it
is dissolved
→Marcha/Paro
Programa (1/24h)
Programa (2/24h)
Programa OFF
↓
OFF*
Configuración
Cloro
Relé
→
Reloj
10 : 44↓
Marcha :
Paro :
↑↓ = SALIR
0 : 00
0 : 00
Cl: 98%
2h 16 min
pH: 6.8
FALTA SAL
16 29
Relé OFF
Semi - auto.
7 . 4 V
1 Marcha:
1 Paro :
2 Marcha:
2 Paro :
0 : 00
0 : 00
0 : 00
0 : 33
Содержание SMARTCL15127