10.4 Configure the settings relating to the logs [Log]
(SW396/SW395/SC386/SC385/SC384/SW175/SW172/
ST165/ST162)
Click the [Log] tab on the “Basic” page. (
®
The settings relating to the log list can be configured in this section.
Alarm
Settings for the alarm log list can be performed.
[Save logs]
Select “On” or “Off” to determine whether to save the alarm logs.
•
On:
Alarm logs will be saved.
•
Off:
Alarm logs will not be saved.
•
Default:
On
Note
•
When “H.264” is selected for “Recording format”, “On” or “Off” will automatically be selected for “Save
logs” according to the setting of “Save trigger”.
•
When “H.264” is selected for “Recording format” and when “Alarm input” is selected for “Save
trigger”, only alarm logs will be saved.
[Name of the destination directory for downloaded images]
Enter the name of the destination directory to which images associated with the logs are to be downloaded.
For example, enter “C:\alarm” to designate the folder “alarm” under drive C.
•
Available number of characters:
3 - 128 characters
•
Available characters:
Alphanumeric characters, the backslash (\), the colon (:), the slash (/), and the
underscore (_).
Manual/Schedule
Configure the settings relating to manual saving or schedule saving of the log list.
Select “On” or “Off” and designate the destination folder in the same manner as for “Alarm”.
Operating Instructions
73
10 Configure the basic settings of the camera [Basic]