background image

Network Camera

Model No.

   

WV-SPN631/WV-SPN611

WV-SPN631

* This illustration represents WV-SPN631

(Please purchase the recommended lens separately.)

This manual describes the installation procedures, network camera installation, cable connections, 

 

and the angle of view adjustment.
Before reading this manual, be sure to read the Important Information.

 

This manual describes how to install the network camera using model WV-SPN631 as an example.

 

PGQX1459YA avs0614-1074 Printed 

in 

China

Standard accessories

Important Information ............................... 1 pc.
Installation Guide (this document) ............ 1 set
Warranty card ........................................... 1 set

CD-ROM*

1

 ................................................ 1 pc.

Code label*

2

 .............................................. 1  pc.

*1  The CD-ROM contains the operating instructions and different kinds of tool software programs. 
*2  This label may be required for network management. The network administrator shall retain the 

code label. 

The following parts are used during installation procedures. 

A

 Tripod mount base ............................... 1 pc.

C

 Safety wire lug ...................................... 1  pc.

E

 Safety wire ........................................... 1 pc.

F

 Washer ................................................. 1 pc.

G

 Spring washer ...................................... 1 pc. 

B

 Power cord plug ................................... 1 pc.

D

 Wire lug fixing screws 

(M2.5 x 8 mm {5/16 inches}) ............. 2 pcs. 
(of them, 1 for spare) 

Slide cover

SD ON/OFF button

Auto back focus button (ABF)

SD slot 1(SD1)

ALC lens connector

SD MOUNT indicator

Clamp for SD memory card

Lens (recommended)

SD slot 2 (SD2)

Major operating controls

 The MONITOR OUT terminal output can be switched for the NTSC monitor/PAL monitor.

 

 How to initialize the camera

 

Follow the steps below to initialize the network camera.

Turn off the power of the camera. When using a PoE hub, disconnect the LAN cable from 
the camera. When using an external power supply, disconnect the power cable plug from 
the 12 V DC power supply terminal.

Turn on the power of the camera while holding down the INITIAL SET button, and then 
keep holding down the button for 5 seconds or more. About 2 minutes later, The camera will 
start up and the settings including the network settings will be initialized.

When an SD memory card

 

*2

 is inserted and could 

Lights off 

 Blinks green 

be recognized 

Lights off

When data can be saved after the SD memory card is 

Lights off 

 Lights green

 

inserted and the SD ON/OFF button is pressed
When data can be saved to the SD memory card 

Lights green

 

When the SD memory card is removed after holding down

 

  Lights green 

 Blinks green 

 Lights off

the SD ON/OFF button for about 2 seconds
When data cannot be saved to the SD memory card because

 

 Lights 

off

an abnormality was detected or the SD memory card is 
configured not to be used

When ABF (Auto Back Focus) operation is being executed

 

  Blinks red (Interval of 1 time/ second)

When the set is being started 

Lights red

 

When an SD memory card is recognized normally 

Lights red 

 Lights off

 

When an abnormality is detected in both SD1 and 

Lights red

 

SD2 cards after the camera has started 
When an abnormality is only detected in the SD1 card 

Lights red 

 Blinks red

 

after the camera has started 

(Interval of 1 time/ 3 seconds)

When an abnormality is only detected in the SD2 card 

Lights red 

 Blinks red

 

after the camera has started 

(Interval of 2 times/ 3 seconds)

IMPORTANT:

This is valid if the [Monitor out] is set to [Switch priority] ([Switch priority] is selected by 

 

default).For details, refer to the Operating Instructions (included in the CD-ROM).

IMPORTANT:

 When the camera is initialized, the settings including the network settings will be initial-

 

ized. Note that the CRT key (SSL encryption key) used for the HTTPS protocol will not 
be initialized.
 Before initializing the settings, it is recommended to write down the settings in advance.

 

 Do not turn off the power of the camera during the process of initialization. Otherwise, it 

 

may fail to initialize and may cause malfunction.

*1  The detailed speci

fi

 cations on the right describe terminals with markings.

*2  SDXC/SDHC/SD memory card is described as SD memory card.

Making connections

Turn off each system’s power supply before making a connection. Before making connections, 
prepare the required peripheral devices and cables.

Before starting the installation, check the entire system configuration. The following illustration 
gives a wiring example of how to connect the camera to the network via a PoE device (hub).

<Required cable>
LAN cable (category 5 or better, straight)
Use a LAN cable (category 5 or better, cross) when directly connecting the camera to a PC.

*1  Recommended cable length from the speaker 

: less than 10 m {32.8 feet}

 

Recommended cable length from the microphone : less than 1 m {3.28 feet}

When connecting to a network using a PoE hub

ø9 mm 

{11/32 inches}

Example of audio cable connector

9 mm 
{11/32 inches}

13 mm {1/2 inches}

Example of LAN cable connector

IMPORTANT:

Connect/disconnect the audio cables and turn on the power of the camera after turning 

 

off the power of the audio output devices. Otherwise, loud noise may be heard from 
the speaker.
Make sure that the stereo mini plug is connected to this cable. When a monaural mini 

 

plug is connected, audio may not be heard. 
When connecting a monaural speaker with amplifier, use a locally procured conversion 
cable (mono-stereo). 

Connect an external amplifier-embedded speaker to the audio output cable

Connect a stereo mini plug (ø3.5 mm) (Audio output is monaural.). Use an external powered speaker.

Output impedance 

: Approx. 600 

Ω

 (unbalanced)

 

Recommended cable length : Less than 10 m {32.8 feet}

 

Output level 

: –20 dBV

 

Microphone/line input cable

Connect a monaural mini plug (ø3.5 mm).

Input impedance: Approx. 2 k

Ω

 (unbalanced)

 

Recommended cable length: Less than 1 m {3.28 feet} (for microphone input)

 

Less than 10 m {32.8 feet} (for line input)

Recommended microphone: Plug-in power type (option)    

Supply voltage: 2.5 V ±0.5 V

 

Input level for the line input: Approx. –10 dBV

 

Recommended sensitivity of microphone: –48 dB ±3 dB (0 dB=1 V/Pa,1 kHz)

 

IMPORTANT:

Use all 4 pairs (8 pins) of the LAN cable.

 

The maximum cable length is 100 m {328 feet}.

 

Make sure that the PoE device in use is compliant with IEEE802.3af standard.

 

When connecting both the 12 V DC power supply and the PoE device for power 

 

supply, 12 V DC will be used for power supply.*

If a 12 V DC power supply and a PoE hub or router are used at the same time, 

network connections may not be possible. In this case, disable the PoE settings. 
Refer to the operating instructions of the PoE hub or router in use.
Depending on the PoE device used, if you disconnect 12 V DC while 12 V DC 

power supply and a PoE hub or router are used at the same time, the power supply 
may stop, causing the camera to restart.

When the LAN cable is disconnected once, reconnect the cable after around 

 

2 seconds. When the cable is quickly reconnected, the power may not be supplied 
from the PoE device.

IMPORTANT:

Do not connect 2 wires or more directly to a terminal. When it is necessary to con-

 

nect 2 or more wires, use a splitter.
Off, input, and output of the external I/O terminal 2 and 3 can be switched by con-

 

figuring the setting. Refer to the Operating Instructions on the provided CD-ROM 
for further information about the EXT I/O terminal 2 and 3 (ALARM IN2, 3) settings 
(“Off”, “Alarm input”, “Alarm output” or “AUX output”).
Install external devices so that they do not exceed the rating of the network camera.

 

When using the EXT I/O terminals as the output terminals, ensure they do not 

 

cause signal collision with external signals.

IMPORTANT:

The adjustment monitor is used for checking the adjustment of the angular field of 

 

view when installing the camera or when servicing. It is not provided for recording/
monitoring use. 
Depending on the monitor, some characters (camera title, preset ID, etc.) may not 

 

be displayed on the screen. 
Use a switching hub or a router which is compliant with 10BASE-T/100BASE-TX. 

 

If a PoE hub is not used, each network camera must be connected to a 12 V DC 

 

power supply.
When using 12 V DC, power supply from a PoE hub or router is not required.

 

Connect a LAN cable (category 5 or better, straight)

Connect the alarm input/output cable

Connect a LAN cable (category 5 or better, straight) to the network connector.

Connect the cables of external devices to the EXT I/O terminal plug.

  When connecting an external device, remove 8 mm - 9 mm {5/16 inches - 11/32 inches} of 

the outer jacket of the cable and twist the cable core to prevent the short circuit first. 

Specification of cable (wire): AWG 20 - AWG 26, Single core, twisted

  Push down the button of the desired terminal on the external I/O terminal plug with a ball-

point pen, and release the button when the cable of the external device is fully inserted 

into the terminal hole.

WV-

SPN63

1

WV-SPN631

PoE device (hub)

PC

LAN cable (category 5 
or better, straight)

Adjustment monitor

Adjustment monitor

LAN cable 
(category 5 or better, straight)

LAN cable 
(category 5 or better, straight)

Powered speaker

Microphone

Powered speaker

Microphone

Recommended total extended 
cable length*

1

Note:

Check whether the stripped part of the wire is not exposed and is securely connected. 

 

<Ratings>

ALARM IN1(DAY/NIGHT IN), ALARM IN2, ALARM IN3

 

Input speci

fi

 cation  :  No-voltage make contact input (4 V - 5 V DC, internally pulled up)

OFF 

:  Open or 4 V - 5 V DC

ON 

:  Make contact with GND (required drive current: 1 mA or more)

ALARM OUT, AUX OUT

 

Output speci

fi

 cation :  Open collector output (maximum applied voltage: 20 V DC)

Open 

:  4 V - 5 V DC by internal pull-up

Close 

:  Output voltage 1 V DC or less (maximum drive current: 50 mA)

* The default of EXT I/O terminals is “Off”.

SD MOUNT indicator

SD ERROR/ABF indicator

NTSC/PAL switch

INITIAL SET button

1 2 3 4

For U.S. and Canada:

Panasonic System Communications 
Company of North America,
Unit of Panasonic Corporation 
of North America

www.panasonic.com/business/
For customer support, call 1.800.528.6747
Two Riverfront Plaza, Newark, NJ 07102-5490

Panasonic Canada Inc.

5770 Ambler Drive, Mississauga, 
Ontario, L4W 2T3 Canada 
(905)624-5010
www.panasonic.ca

For Europe and other countries:

Panasonic Corporation

http://panasonic.net

Panasonic System Networks Co., Ltd. 
Fukuoka, Japan

Authorised Representative in EU:   

Panasonic Testing Centre
Panasonic Marketing Europe GmbH
Winsbergring 15, 22525 Hamburg, Germany

Installation Guide

Included Installation Instructions

Panasonic System Networks Co., Ltd. 2014

*1 Network connector RJ45

MONITOR OUT terminal
(factory shipment: NTSC monitor)

*1 Microphone/line input connector

*1 Audio output connector

*1 EXT I/O terminals

*1 12 V DC power supply terminal

The component names of the camera are as follows. Refer to the illustration when installing or 

adjusting the camera.

When data is being sent via the network camera 

Blinks green (accessing)

 

When the camera is able to communicate with  

Lights orange

 

the connected device

ACT indicator

LINK indicator

− +

B

IMPORTANT:

The 12 V DC power supply shall be insulated from the commercial AC power.

 

Be sure to use the power cable plug provided with this product.

 

Be sure to fully insert the power cable plug into the 12 V DC power supply terminal. 

 

Otherwise, it may damage the camera or cause malfunction.
When installing the camera, make sure that excessive force is not applied to the 

 

power cable.
Be sure to use an AC adaptor compliant with the Specifications (written in the indi-

 

cation label on the bottom side of this unit) regarding power source and power con-
sumption.

Caution:

A READILY ACCESSIBLE DISCONNECT DEVICE SHALL BE INCORPORATED 

 

TO THE EQUIPMENT POWERED BY 12 V DC POWER SUPPLY.
ONLY CONNECT 12 V DC CLASS 2 POWER SUPPLY (UL 1310/CSA 223) or 

 

LIMITED POWER SOURCE (IEC/EN/UL/CSA 60950-1).

Connect the power cable

Connect the output cable of the DC power supply to the power cable plug (accessory).

q  

Loosen the screw of the power cable plug (accessory), strip 3 mm to 7 mm {1/8 inches to 
9/32 inches} from the end of the wire, twist the stripped part of the wire sufficiently to avoid 
short circuit, and then connect the output cable to the power cable plug (accessory).

 Tighten the screw of the power cable plug. (Recommended tightening torque: 0.34 N·m 
{0.25 lbf·ft})

Note:

Check whether the stripped part of the wire is not exposed and is securely con-

 

nected.
When connecting an external power supply to the camera, use the AWG 16 to 

 

AWG 24 single-wired or stranded wired cables.

ALARM IN1, DAY/NIGHT IN
(Alarm input terminal 1, DAY/NIGHT input terminal)
ALARM IN2, ALARM OUT
(Alarm input terminal 2, Alarm output terminal)
ALARM IN3, AUX OUT
(Alarm input terminal 3, AUX output terminal)
GND

External I/O terminal plug

button

Отзывы: