43
When an all reset is carried out, the main unit settings that can be set using the menu functions of this equipment are all reset to
their initial states.
Since the main unit settings are reset to the initial states, first-time setup will be necessary when the power to this equipment is
switched ON next and this equipment is started again. For details, refer to “First-time Setup” (
☞
The settings that are initialized by an all reset are the following.
• Display/Buzzer Adjustment
• Joystick settings
• Network settings
• Auto Login/Auto Logout Setting
• Settings of the administrator
• Settings of operators
• Function Level settings
Operation procedure
1
Switch ON the power supply while keeping pressed
+
+
The all reset execution confirmation screen is displayed.
2
Press
The all rest execution screen is displayed for a few seconds.
After that, the display transitions to the all reset execution
completion screen.
3
Switch OFF the power supply
Maintenance
(continued)
All Reset