Functions
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
125
3-11-8 Override Function
Item
Description
Settings / ranges
Factory default
setting
Override valid time
You can change the maximum
time that the override state can
be maintained.
0 (invalid)
1 to 600 sec. (increments of 1 sec.)
60 sec.
When the muting disconnection detection function is valid, the override function is released
when a circuit break occurs.
3-11-9 Protection Function
Item
Description
Settings / ranges
Factory default
setting
Protection function
You can require that a pass-
word (4 alphanumeric digits)
be entered in order to change
device settings.
Invalid (settings can be changed
without entering a password)
Invalid
Valid (password required to
change settings)
3-11-10 I/O Setting Function
Item
Description
Settings / ranges
Factory default
setting
I/O setting function
You can select from placement
patterns with a determined input
signal and non-safety output
signal.
This depends on the selected
cable.
For details, refer to the “
SF4D-TM1
User's Manual
”.
Invalid
<Reference>
Some inputs and outputs such as the control outputs (OSSD 1 / 2) and power cabling cannot be
changed.
Содержание WUME-SF4D-4
Страница 2: ... Panasonic Industrial Devices SUNX Co Ltd 2017 2 MEMO ...
Страница 126: ...Functions Panasonic Industrial Devices SUNX Co Ltd 2017 126 MEMO ...
Страница 130: ...Maintenance Panasonic Industrial Devices SUNX Co Ltd 2017 130 MEMO ...
Страница 140: ...Troubleshooting Panasonic Industrial Devices SUNX Co Ltd 2017 140 MEMO ...
Страница 174: ... Panasonic Industrial Devices SUNX Co Ltd 2017 174 MEMO ...