Functions
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
124
■Changing the muting sensor output setting
The muting sensor output setting can be changed to NONC (Normally Open / Normally Closed)
to validate operation even when there is no input time difference.
<NONO [Normally Open / Normally Open (factory default setting)]>
Auxiliary output
Muting input
Input time
difference
Operation
when ON
Operation
when OFF
NO (Normally Open) type
ON when light not received (photo
-
electric sensor, etc.)
ON when object approaches (proxim
-
ity sensor, etc.)
ON when contact occurs (position
switch, etc.)
A, B
0.03 to 3 sec.
*Can be changed
0V or +V
Open
<NONC [Normally Open / Normally Closed]>
Auxiliary output
Muting input
Input time
difference
Operation
when ON
Operation
when OFF
NO (Normally Open) type
ON when light not received (photo
-
electric sensor, etc.)
ON when object approaches (proxim
-
ity sensor, etc.)
ON when contact occurs (position
switch, etc.)
A
0 to 3 sec.
(Simultaneous
input possible)
*Can be changed
0V or +V
Open
NC (Normally Closed) type
ON when light received (photoelectric
sensor, etc.)
ON when object moves away (prox
-
imity sensor, etc.)
ON when contact does not occur (posi
-
tion switch, etc.)
B
■Exit-only muting function
When the exit-only muting function is used, a muting sensor is only installed on the danger zone
side. There is no need for installation on the safe zone side. The conditions required for the exit-
only muting function are described below.
<Installation conditions for exit-only muting>
●
The detected object must move from the danger zone to the safe zone.
● One-way movement only.
●
The detected object must pass through the sensing area within 4 seconds after muting sen-
sor 1 or 2 turns OFF.
<Start conditions for muting>
Same.
<Release conditions for muting>
The following release conditions change when exit-only muting is used.
● Blocking continues even after an elapse of 4 seconds after muting input A or B is OFF at ap
-
prox. 20ms or more.
●
When the device changes to the light receiving state.
Содержание WUME-SF4D-4
Страница 2: ... Panasonic Industrial Devices SUNX Co Ltd 2017 2 MEMO ...
Страница 126: ...Functions Panasonic Industrial Devices SUNX Co Ltd 2017 126 MEMO ...
Страница 130: ...Maintenance Panasonic Industrial Devices SUNX Co Ltd 2017 130 MEMO ...
Страница 140: ...Troubleshooting Panasonic Industrial Devices SUNX Co Ltd 2017 140 MEMO ...
Страница 174: ... Panasonic Industrial Devices SUNX Co Ltd 2017 174 MEMO ...