background image

• Select and add input devices (e.g. buttons). Should you already 

have installed Touch4Light functions, these can be selected here 
as well.

• Once an input device has been selected, diverse parameters 

can be defined for the functions performed by the input device. 
These settings then apply to the selected group.  
ADVANTAGE: Input devices can be used with various functions 
and parameters in different groups.

• If input devices are to be used to activate a light scene, the 

"Scene [M]" function must be assigned to the respective input 
devices.

Definition of Light Scenes

Configuration -> Scenes 

• Up to 16 different light scenes can be defined per group.
• All scenes assigned in the "Group Functions" menu item are 

displayed in the "Scene" menu item.

• Within a scene, all the luminaires in the respective group are 

listed and individual light values can be adjusted.

• Individual scenes can thus be created for each group.

 

„

ADVANCED FUNCTIONS

 

The "Advanced Functions" menu item contains useful additional 
functions with which luminaire groups can be controlled, system 
architecture can be displayed or maintenance functions can be 
optimised. These must subsequently be integrated into the "Group 
Functions" menu.
• Daily Schedule -> Weekly Schedule*
• Astronomical control*
• Room plan
• Component replacement
• Flexible room usage (EnOcean)
• Night-guard*
• Group dynamics
• Random RGB behavior

IMPORTANT

N

This is dependent on the correct system time being 
set in the LightBox.

 

„

NOTES ON USING VS EXTENDERS

VS Extenders provide an affordable option for simultaneously 
addressing (bundling) up to 64 DALI control gear units with only 
one DALI address. Integrating a VS Extender into a light manage-
ment system that includes a VS Light Controller will limit the entire 
system to its basic control and adjustment functions. Sensors can 
nevertheless be integrated via the primary DALI line. However, all 
functions that are based on luminaire feedback will no longer func-
tion properly as long as the VS Extender is connected. These limi-
tations are particularly relevant with regard to Vossloh-Schwabe’s 
Light Controller IP DALI since functions such as individual addres-
sing, component exchange and automatic error detection and 
many others will no longer be available for use.

4

Quick Start Guide Light Controller IP/DALI

Quick-Star

t-Guide_Light Controller IP_EN_08. Juli, 2019

Vossloh-Schwabe Deutschland GmbH

 · Hohe Steinert 8 · 58509 Lüdenscheid · Germany · Tel. +49 (0) 23 51/10 10 · Fax +49 (0) 23 51/10 12 17 · www.vossloh-schwabe.com

A Member of the Panasonic Group

Содержание Vossloh-Schwabe Light Controller IP/DALI 2CH

Страница 1: ... N Only one DHCP server may be installed in the network at any time Operating Option 1 Server based Installation LightBox DHCP Connect a monitor via HDMI We recommend setting the pre installed Mozilla Firefox browser as your default browser Open browser and enter the following URL http 127 0 0 1 Operating Option 2 Client based Installation e g tablet or PC For LightBox DHCP Ref No 186513 Wireless ...

Страница 2: ...ires Line B Group 1 Group 2 Menu Luminaire Search Setup Menu Functional Mapping Buttons Touch 4 Light DALI Scene Sensors Advanced Functions e g timer program Menu Grouping Quick Start Guide Light Controller IP DALI Quick Start Guide_Light Controller IP_EN_08 Juli 2019 Vossloh Schwabe Deutschland GmbH Hohe Steinert 8 58509 Lüdenscheid Germany Tel 49 0 23 51 10 10 Fax 49 0 23 51 10 12 17 www vossloh...

Страница 3: ...ting call up lighting scenes and activate time controlled light sequences IMPORTANT Integrating VS Extenders will limit the entire system to its basic control and adjustment functions Please observe the information provided on page 5 3 CONFIGURATION OF SYSTEM COMPONENTS Creation of Luminaire Groups Configuration Groups Allocate group name e g office kitchen hallway etc Assign luminaires to the gro...

Страница 4: ...ed into the Group Functions menu Daily Schedule Weekly Schedule Astronomical control Room plan Component replacement Flexible room usage EnOcean Night guard Group dynamics Random RGB behavior IMPORTANT N This is dependent on the correct system time being set in the LightBox NOTES ON USING VS EXTENDERS VS Extenders provide an affordable option for simultaneously addressing bundling up to 64 DALI co...

Страница 5: ...c to their position and function via the Extended Functions Replace Components menu Data Storage System configuration settings can be saved under System Settings Download Current Settings We recommend this download step is performed after every relevant change of the configuration settings This file should not be saved on the server but at another storage location as a backup file Restore System S...

Страница 6: ...40 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 Secure Area Inadmissible Area Quick Start Guide Light Controller IP DALI Quick Start Guide_Light Controller IP_EN_08 Juli 2019 Vossloh Schwabe Deutschland GmbH Hohe Steinert 8 58509 Lüdenscheid Germany Tel 49 0 23 51 10 10 Fax 49 0 23 51 10 12 17 www vossloh schwabe com A Member of the Panasonic Group 6 ...

Отзывы: