© Panasonic Corporation 2017
1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8501, Japan
http://www.panasonic.com
PNQW5442ZA
C0917MM1
Model No.
VL-V591
Installation Guide for the Flush Mounted Box and the Power Supply Unit
Before installation
Important:
L
To avoid malfunction or communication disturbances, do not install the lobby station in the following locations:
– Places where vibration or any other kind of impact occurs.
– Places near hydrogen sulfide.
L
Do not place other devices or obstacles in the area around
the main unit shown in the figure.
L
Do not install the power supply unit in the following places:
– Places where the power supply unit may be splashed with water or
chemicals.
– Places where there is a high concentration of dust, or high humidity.
Top view
Image range:
960 mm
500 mm
87°
Installation position of the main unit and camera range
5 mm 5 mm
15 mm
20 cm
Main
unit
Installing on a vertical flat wall
Installing on a tilted pedestal
L
Do not install on a pedestal tilted at less than 45°.
The camera angle can be
adjusted using the camera
angle control lever on the
rear of the upper cabinet,
so that the image range can
be changed. Refer to the
main unit’s installation and
operation guide.
(Pitch of fixing screw)
(Pitch of fixing screw)
(Aperture dimension)
148 mm
136 mm
162 mm
280 mm 326 mm
340 mm
<Side view>
80 mm
340 mm
Drilling dimension of wall surface for the flush mounted box
Open the kn
ockout holes of the flush mounted box, and
put the wires from each room and the door opener, and the
DC cable from the power supply unit through the holes.
Mount the box in the wall.
Knockout holes
Wall
DC cable connected to
the power supply unit
Wires connected to
rooms and the door
opener
Installing the flush mounted box in the wall
L
Please read the main unit’s installation and operation guide with this guide before installation.
L
If you intend to install the power supply unit later, return it to the box, and keep it until required.
Side view when the camera is
installed lower than the standard
position, and facing upwards at 15°.
Example: Installation height is 980 mm.
Side view when the camera is facing
forwards at 0° (de
fault).
Example: Installation height is 1330 mm
(standard position).
Side view when the camera is installed on a pedestal
tilted at 60°, and facing forwards at 0° (default)
.
Example: Installation height is 1100 mm.
Side view when the camera is installed on a
pedestal tilted at 45°, and facing downwards at 5°.
Example: Installation height is 1120 mm.
1330 mm
1810 mm
Center of
main unit
66° 650 mm
Image
range
1160 mm
500 mm
PP
PP
PP
PP
PP
,PDJH
UDQJH
&HQWHURI
PDLQXQLW
1690 mm
980 mm
710 mm
500 mm
980 mm
Image
range
Center of
main unit
66°
PP
PP
PP
PP
PP
,PDJH
UDQJH
&HQWHURI
PDLQXQLW
Installing the power supply unit on the wall
A DC cable is not included. You need to prepare one. For details, refer to the wire type and distance section in the main
unit’s installation and operation guide.
About the installation location
L
The AC cable plug is used as the main disconnect device.
Ensure that the power outlet is installed near the product
and is easily accessible.
L
A readily accessible disconnect device shall be
incorporated external to the equipment.
–
External disconnect device must be certified and have a
creepage and clearance distance of 3 mm or more.
Precautions for wiring
L
Make sure that the power supply unit is unplugged before
performing any wiring work.
L
Always connect AC or DC cables to the appropriate
connector or connection terminal.
L
To prevent the DC cable from disconnecting and to prevent
electric shock, secure the DC cable using the cable binder
(accessory) and attach the cable cover.
How to connect the AC cable and DC cable:
Connect the power supply unit (accessory), the AC cable
(accessory), and a DC cable (locally procured).
A
B
Power Supply Unit (VL-PS241) side:
1
25 mm
2
7 mm
Lobby Station (VL-V591) side:
1
52 mm or more
2
12 mm
Front view
E
F
G H
*1
C
D
*1
Make sure that there are no bare wires exposed outside
the product.
Power supply unit (with cable cover removed)
K
I
J
Bottom view
Top view
k
DC cable binder hole
1
Strip the DC cables as follows:
DC cable (
1
,
2
)
2
Remove the screws (
3
) and then remove the cable
cover (
4
).
3
Connect the AC cable (
5
) (accessory) to the AC IN
connector (
9
) on the top of the power supply unit. Next,
connect the DC cable (
7
) (locally procured) to the DC
OUT terminal (
j
) on the bottom of the power supply
unit, and then secure the wires by tightening the screws
(
6
).
L
Recommended torque: 0.45 N·m {4.6 kgf·cm}
Insert the cables firmly all the way into the
connector and terminals. If the cables are not
inserted all the way, heat may be generated.
CAUTION
4
Use the cable binder (
8
) (accessory) to secure the DC
cable (
7
) (double-coated area) to the power supply
unit.
5
Make sure to replace the cable cover (
4
).
Wall mounting
Attach the power supply unit to the wall securely.
1
Screws (accessory) x
2
A
V590CX_Flush Mount box leaflet.indd 1
2017/09/22 19:00:07