Wireless Video Intercom System
Key Features
• Wireless Handset:
Check visitors on Wireless Monitor, respond promptly and talk from living room, kitchen, everywhere home and while you are doing something else. UP to 6 wireless
monitor connectable. Max wireless range is 100m with no obstacles. You can add on repeaters expand the range. UP to 2 DECT repeater connectable.
• Large Touch Panel:
The main monitor has a large, 5 inch wide screen that clearly shows each visitor's face. You can simply touch the screen to activate an approximate 2x zoom
horizontally and vertically.
• Electric Lock Release Support for Gate:
The gate or door lock can be easily and quickly released even from the second fl oor of the house.
• Wide-Angle Camera:
Wide-angle lens covers approximately 170 degrees horizontally and 115 degrees vertically.
• SD Card Recording:
Automatically record video images of visitors to SD card. It will record up to 3,000 visitors (30 seconds per visitor). (The SD Memory Card is sold separately.)
• Wireless Sensor Cameras:
By installing the optional DECT Wireless Sensor Camera, you can use human (heat) and motion sensors to monitor locations that you are concerned about.
UP to 4 wireless sensor camera connectable.
Door Station
(Doophone)
VL-V554BX
VL-V554UBX
DECT Repeater
VL-FKD2BX
Lobby Station
VL-V590BX
VL-V590CX
Wireless
Monitor Station
(Sub monitor)
VL-WD613BX
Main Monitor
Station
(Main monitor)
VL-MWD501BX
Wireless Sensor Camera
VL-WD812BX
For the Sub Monitor:
AC adaptor × 2 (PNLV226BX [2 pin AC plug] / PNLV226E [3 pin AC plug]), Rechargeable batteries × 2, Charger × 1
For the Door Station:
<VL-V554BX>
Mounting base × 1 & screw (3.8 mm x 20 mm) × 2, Screw (4 mm x 12 mm) × 4, Name plate × 2, Hex wrench × 1
<VL-V554UBX>
Flush mounting box × 1, Screw (4 mm x 25 mm) × 4, Name plate × 2, Hex wrench × 1
For the Main Monitor Station:
Power supply unit* (VL-PS241) × 1, Mounting bracket × 1, Cable binder × 1, Screw (4 mm x 16 mm) × 2
*Including AC cable × 2, Cable binder × 1, Screw (4 mm x 40 mm) × 2
Wiring Schematic Diagram
Accessory Information
Optional Accessories
Relative Product
Up to 20 Main
monitors
connectable
POWER SUPPLY UNIT
DOORPHONE 1
MAIN MONITOR
DOORPHONE 2
220-240 V AC
Connection device for option output (A contact)
• When using an optional lobby station, this terminal is used by the lobby station. (In this case, connection
devices for option output (A concatc) cannot be connected.)
NP: Non-polarised
12 V AC/DC
12 V AC/DC
Electric lock
Electric lock
(Optional lobby station can be connetcted.)
24 V DC
A
B
D
C
C
NP
NP
NP
NP
NP
NP
Power
supply
Power
supply
MAIN MONITOR STATION
LOBBY STATION
Electric lock
30 V AC/
24 V DC
NP
NP
NP
<Rear view>
<Rear view>
Power
supply
Wire type and length
Wiring run
Wire type*
1
Diameter
Length (Max.)
Main monitor – Doorphone
φ
0.65 mm
22 AWG
100 m
φ
1.0 mm
18 AWG
130 m
φ
0.5 mm
CAT 5
50 m
Main monitor – Power supply unit
φ
0.65 mm
22 AWG
10 m
φ
1.0 mm
18 AWG
20 m
Doorphone – Electric lock*
2
φ
0.5 mm -
φ
1.2 mm (24 AWG - 17 AWG)
According to specifi cation of connected device.
Main monitor – Connection device for
option output (A contact)*
2
φ
0.5 mm -
φ
1.2 mm (24 AWG - 17 AWG)
According to specifi cation of connected device.
Wireless sensor camera –
Power supply unit
–
φ
0.65 mm
22 AWG
50 m
φ
1.0 mm
18 AWG
100 m
Wireless sensor camera –
External sensor
–
φ
0.5 mm -
φ
0.8mm (24 AWG - 20 AWG)
According to specifi cation of connected device.
Must be no longer than 20 m.
*1 Type: Single-pair cable with outer sheath (jacket) Conductor: Copper
solid
• A certifi ed power supply wiring has to be used with this equipment.
The relevant national installation and/or equipment regulations shall
be considered. A certifi ed power supply wiring not lighter than ordinary
polyvinyl chloride fl exible wiring according to IEC 60227 shall be used.
*2 When using an electric lock or a connection device for option output (A
contact), select a device that meets the following guidelines:
• Electric lock connection terminal (S1/S2):
- N/O dry closure contact
- 12 V AC/DC, less than 1 A
• Connection device for option output (A contact) terminal (OUT1/OUT2):
- 24 V AC/DC, less than 0.3 A (minimum contact: 5 V DC 1 mA)