background image

Wireless Video Intercom System

Key Features

• Wireless Handset: 

Check visitors on Wireless Monitor, respond promptly and talk from living room, kitchen, everywhere home and while you are doing something else. UP to 6 wireless 

monitor connectable. Max wireless range is 100m with no obstacles. You can add on repeaters expand the range. UP to 2 DECT repeater connectable.

• Large Touch Panel:

The main monitor has a large, 5 inch wide screen that clearly shows each visitor's face. You can simply touch the screen to activate an approximate 2x zoom 

horizontally and vertically. 

• Electric Lock Release Support for Gate:

 

The gate or door lock can be easily and quickly released even from the second fl oor of the house.

• Wide-Angle Camera:

 Wide-angle lens covers approximately 170 degrees horizontally and 115 degrees vertically.

 

• SD Card Recording: 

Automatically record video images of visitors to SD card. It will record up to 3,000 visitors (30 seconds per visitor). (The SD Memory Card is sold separately.)

 

• Wireless Sensor Cameras:

By installing the optional DECT Wireless Sensor Camera, you can use human (heat) and motion sensors to monitor locations that you are concerned about. 
UP to 4 wireless sensor camera connectable.

 

Door Station

(Doophone)

VL-V554BX

VL-V554UBX

DECT Repeater

VL-FKD2BX

Lobby Station

VL-V590BX

VL-V590CX

Wireless 

Monitor Station

(Sub monitor)

VL-WD613BX

Main Monitor 

Station 

(Main monitor)

VL-MWD501BX

Wireless Sensor Camera

VL-WD812BX

For the Sub Monitor:

 AC adaptor × 2 (PNLV226BX [2 pin AC plug] / PNLV226E [3 pin AC plug]), Rechargeable batteries × 2, Charger × 1

For the Door Station: 

<VL-V554BX> 

Mounting base × 1 & screw (3.8 mm x 20 mm) × 2, Screw (4 mm x 12 mm) × 4, Name plate × 2, Hex wrench × 1

<VL-V554UBX> 

Flush mounting box × 1, Screw (4 mm x 25 mm) × 4, Name plate × 2, Hex wrench × 1

For the Main Monitor Station: 

Power supply unit* (VL-PS241) × 1, Mounting bracket × 1, Cable binder × 1, Screw (4 mm x 16 mm) × 2

*Including AC cable × 2, Cable binder × 1, Screw (4 mm x 40 mm) × 2

Wiring Schematic Diagram

Accessory Information

Optional Accessories

Relative Product

Up to 20 Main 

monitors 

connectable

POWER SUPPLY UNIT

DOORPHONE 1

MAIN MONITOR

DOORPHONE 2

220-240 V AC

Connection device for option output (A contact)

• When using an optional lobby station, this terminal is used by the lobby station. (In this case, connection 

devices for option output (A concatc) cannot be connected.)

NP: Non-polarised

12 V AC/DC

12 V AC/DC

Electric lock

Electric lock 

(Optional lobby station can be connetcted.)

24 V DC

A

B

D

C

C

NP

NP

NP

NP

NP

NP

Power 

supply

Power 

supply

MAIN MONITOR STATION

LOBBY STATION

Electric lock

30 V AC/

24 V DC

NP

NP

NP

<Rear view>

<Rear view>

Power 

supply

 Wire type and length

Wiring run

Wire type*

1

Diameter

Length (Max.) 

Main monitor – Doorphone

φ

 0.65 mm

22 AWG

100 m

φ

 1.0 mm

18 AWG

130 m

φ

 0.5 mm

CAT 5

50 m

Main monitor – Power supply unit

φ

 0.65 mm

22 AWG

10 m

φ

 1.0 mm

18 AWG

20 m

Doorphone – Electric lock*

2

φ

 0.5 mm - 

φ

 1.2 mm (24 AWG - 17 AWG)

According to specifi cation of connected device.

Main monitor – Connection device for 

option output (A contact)*

2

φ

 0.5 mm - 

φ

 1.2 mm (24 AWG - 17 AWG)

According to specifi cation of connected device.

Wireless sensor camera –

Power supply unit

φ

 0.65 mm

22 AWG

50 m

φ

 1.0 mm

18 AWG

100 m

Wireless sensor camera –

External sensor

φ

 0.5 mm - 

φ

 0.8mm (24 AWG - 20 AWG)

According to specifi cation of connected device. 

Must be no longer than 20 m.

*1 Type: Single-pair cable with outer sheath (jacket) Conductor: Copper 

solid

• A certifi ed power supply wiring has to be used with this equipment. 

The relevant national installation and/or equipment regulations shall 
be considered. A certifi ed power supply wiring not lighter than ordinary 
polyvinyl chloride fl exible wiring according to IEC 60227 shall be used.

*2 When using an electric lock or a connection device for option output (A 

contact), select a device that meets the following guidelines:

• Electric lock connection terminal (S1/S2): 
- N/O dry closure contact
- 12 V AC/DC, less than 1 A
• Connection device for option output (A contact) terminal (OUT1/OUT2): 
- 24 V AC/DC, less than 0.3 A (minimum contact: 5 V DC 1 mA)