11.3.2. When replacing BBIC and X’tal
n
Preparation:
1. PC setting refer to “
2. Supply DC 2.6V at CL5.
Note:
Test points: Refer to
• After finishing the adjustment, turn off and disconnect the 3-Wire cable.
No.
Items
Check Point
Procedure
1 1.8 V Supply Adjustment
CL3(BB1.8V)
1.Confirm that the voltage between test point CL3 and CL9 (GND) is
1.8 V ± 0.02 V.
2.Execute the command “VDD”, then check the current value.
3.Adjust the 1.8V voltage of VDD1 executing command “VDD XX” (XX is the
value).
2 3.0 V Supply Confirmation CL4(BB3.0V)
1.Confirm that the voltage between test point CL4 and CL9 (GND) is
3.0 V ± 0.2 V.
3 BBIC Clock Adjustment
CL1 (BXTAL)
1.Confirm frequency between CL1 and CL9 (GND).
2.Input Command “sfr”, then you can confirm the current value.
3.Check X’ tal Frequency. (10.368 MHz ± 100 Hz).
4.If the frequency is not 10.368 MHz ± 100 Hz, adjust the frequency of CKM
executing the command “sfr xx xx” (where xx xx is the value: d) so that the
reading of the frequency counter is 10.368000 MHz ± 5 Hz.
4 Transmitted Power
Check and Adjustment
TP-ANT1
Remove the wire Antenna before starting step from 1 to 5.
1.Configure the DECT tester (CMD60) as follows;
<Setting>
- Test mode: PP
- RFPI: 0102030405
- Traffic Carrier: 5
- Traffic Slot: 4
- Mode: Loopback/RF LEVEL = -70 dBm
- PACKET: PP32Z
2.Execute the command “PAP”.
3.Execute the command “TST 01 02 03 04 05”.
4.Initiate connection from DECT tester.
5.Confirm that the NTP value at ANT is 20 dBm ~ 24 dBm.
executing the command “PAP 29 70” (“PAP 2* 70” where * is the value:
* = 7~9~B)
so that the reading of the NTP value is 22 ± 2 dBm.
Be care NOT to make Cable-loss between DECT tester and Target Set.
5 Modulation Check and
Adjustment
TP-ANT1
Follow steps 1 to 4 of (4).
5.Confirm that the B-Field Modulation is -350 ± 50/+350 ± 50 kHz/div using
datatype Fig31.
6 Frequency Offset Check
TP-ANT1
Follow steps 1 to 4 of (4).
5.Confirm that the frequency offset is < ± 20 kHz.
7 Sensitivity Receiver Confir-
mation
TP-ANT1
Follow steps 1 to 4 of (4).
5.Set DECT tester power to -88 dBm.
6.Confirm that the BER is < 1000 ppm.
8 Power RAMP Confirmation TP-ANT1
Follow steps 1 to 4 of (4).
5.Confirm that Power RAMP is matching.
Содержание VL-SWD272BX
Страница 2: ...2 VL SWD272BX SWD272CX SWD272CX1 SWD272AZ VL WD613CX VL WD613CX1 ...
Страница 21: ...21 VL SWD272BX SWD272CX SWD272CX1 SWD272AZ VL WD613CX VL WD613CX1 8 1 2 Wireless Monitor Station ...
Страница 30: ...30 VL SWD272BX SWD272CX SWD272CX1 SWD272AZ VL WD613CX VL WD613CX1 ...
Страница 31: ...31 VL SWD272BX SWD272CX SWD272CX1 SWD272AZ VL WD613CX VL WD613CX1 ...
Страница 50: ...50 VL SWD272BX SWD272CX SWD272CX1 SWD272AZ VL WD613CX VL WD613CX1 ...
Страница 51: ...51 VL SWD272BX SWD272CX SWD272CX1 SWD272AZ VL WD613CX VL WD613CX1 ...
Страница 52: ...52 VL SWD272BX SWD272CX SWD272CX1 SWD272AZ VL WD613CX VL WD613CX1 ...
Страница 53: ...53 VL SWD272BX SWD272CX SWD272CX1 SWD272AZ VL WD613CX VL WD613CX1 ...
Страница 54: ...54 VL SWD272BX SWD272CX SWD272CX1 SWD272AZ VL WD613CX VL WD613CX1 ...
Страница 108: ...108 VL SWD272BX SWD272CX SWD272CX1 SWD272AZ VL WD613CX VL WD613CX1 16 1 4 Charger 305 M PCB301 305 303 304 306 301 302 ...