113
UF-5500 / 4500
10.1.4.4. Binary Signal (V.34)
This Service Mode is used to check the binary signal output. Signals can be output to the line using the
following procedure. (V.34)
Binary Signal Table
Service Mode 4 - Binary Signal
Step
Operation or Unit Condition
LCD Display
(The pictured model is UF-5500.)
1
Standby
2
Press “FUNCTION” and then “7”.
3
Press “MONITOR” four times, then press “*”.
4
Enter the key operator password (The factory default ID is 00000000.) and press
"Set".
5
Press “4”.
6
Press “5” and “START”.
7
Enter the signal number (01-61) and press [START] to select the binary signal.
8
Press "CLEAR" to end the signal generation. To select another signal, repeat step 7.
9
Press "STOP" twice to return to standby.
Number
Signals
Number
Signals
Number
Signals
01
V34 2400 sr 2400 bps
22
V34 3000 sr 9600 bps
43
V34 3429 sr 4800 bps
02
V34 2400 sr 4800 bps
23
V34 3000 sr 12000 bps
44
V34 3429 sr 7200 bps
03
V34 2400 sr 7200 bps
24
V34 3000 sr 14400 bps
45
V34 3429 sr 9600 bps
04
V34 2400 sr 9600 bps
25
V34 3000 sr 16800 bps
46
V34 3429 sr 12000 bps
05
V34 2400 sr 12000 bps
26
V34 3000 sr 19200 bps
47
V34 3429 sr 14400 bps
06
V34 2400 sr 14400 bps
27
V34 3000 sr 21600 bps
48
V34 3429 sr 16800 bps
07
V34 2400 sr 16800 bps
28
V34 3000 sr 24000 bps
49
V34 3429 sr 19200 bps
08
V34 2400 sr 19200 bps
29
V34 3000 sr 26400 bps
50
V34 3429 sr 21600 bps
09
V34 2400 sr 21600 bps
30
V34 3000 sr 28800 bps
51
V34 3429 sr 24000 bps
10
V34 2800 sr 4800 bps
31
V34 3200 sr 4800 bps
52
V34 3429 sr 26400 bps
11
V34 2800 sr 7200 bps
32
V34 3200 sr 7200 bps
53
V34 3429 sr 28800 bps
12
V34 2800 sr 9600 bps
33
V34 3200 sr 9600 bps
54
V34 3429 sr 31200 bps
13
V34 2800 sr 12000 bps
34
V34 3200 sr 12000 bps
55
V34 3429 sr 33600 bps
14
V34 2800 sr 14400 bps
35
V34 3200 sr 14400 bps
56
ANSam
15
V34 2800 sr 16800 bps
36
V34 3200 sr 16800 bps
57
CM
16
V34 2800 sr 19200 bps
37
V34 3200 sr 19200 bps
58
JM
17
V34 2800 sr 21600 bps
38
V34 3200 sr 21600 bps
59
INFO0c & TONEB
18
V34 2800 sr 24000 bps
39
V34 3200 sr 24000 bps
60
INFO0c & TONEA
19
V34 2800 sr 26400 bps
40
V34 3200 sr 26400 bps
61
PPh & AC & ALT
20
V34 3000 sr 4800 bps
41
V34 3200 sr 28800 bps
21
V34 3000 sr 7200 bps
42
V34 3200 sr 31200 bps
Содержание UF-4500
Страница 180: ...180 UF 5500 4500 ...
Страница 248: ...248 UF 5500 4500 13 5 Test Chart 13 5 1 ITU T No 1 Test Chart ...
Страница 249: ...249 UF 5500 4500 13 5 2 ITU T No 2 Test Chart ...
Страница 281: ...281 UF 5500 4500 10 10 11 15 12 17 18 19 20 21 22 23 24 28 29 30 27 25 26 21 13 14 16 30 ...
Страница 287: ...287 UF 5500 4500 130 131 132 133 134 135 136 137 138 139 140 141 PCB2 A UF 5500 only CN1 ...
Страница 289: ...289 UF 5500 4500 PCB8 PCB4 160 161 163 162 164 167 168 171 177 178 172 173 174 173 176 169 170 162 164 A A 165 ...
Страница 297: ...297 UF 5500 4500 ...
Страница 305: ...305 UF 5500 4500 ...
Страница 309: ...309 UF 5500 4500 A1 A3 A4 A6 A7 A8 A9 A10 P1 P2 P3 P4 P5 P6 P7 P8 P7 Drum Cartridge Toner Cartridge P9 A11 ...
Страница 311: ...311 UF 5500 4500 501 502 503 504 506 507 505 508 509 511 510 514 513 512 P51 P53 P54 A51 P52 ...
Страница 362: ...362 UF 5500 4500 ...
Страница 365: ...365 UF 5500 4500 Published in Japan ...