2007 Matsushita Electric Industrial Co., Ltd. All
rights
reserved.
Unauthorized
copying
and
distribution is a violation of law.
TH-58PH10UK
GPH10D Chassis
High Definition Plasma Display
Specifications
Power Source
120 V AC, 50/60 Hz
Power Consumption
Power on
660 W
Stand-by condition
Save OFF 0.6 W, Save ON 0.4 W
Power off condition
0.1 W
Plasma Display panel
Drive method: AC type 58-inch,
16:9 aspect ratio
Screen size
50.7” (1,287 mm) (W) × 28.5” (723 mm) (H) × 58” (1,476 mm) (diagonal)
(No. of pixels)
1,049,088 (1,366 (W) × 768 (H)) [4,098 × 768 dots]
Operating condition
Temperature
32 °F - 104 °F (0 °C - 40 °C)
Humidity
20 % - 80 %
Applicable signals
Color System
NTSC, PAL, PAL60, SECAM, Modified NTSC
Scanning format
525 (480) / 60i 60p, 625 (575) / 50i 50p, 750 (720) / 60p 50p, 1125 (1080) / 60i 50i 24p 25p
30p 24sF .... SMPTE274M, 1250 (1080) / 50i
PC signals
VGA, SVGA, XGA,
SXGA, UXGA ..... (compressed)
Horizontal scanning frequency 15 - 110 kHz
Vertical scanning frequency 48 - 120 Hz
Connection terminals
AV IN
VIDEO IN (BNC)
1.0 Vp-p (75-ohm)
S VIDEO IN (MINI DIN 4PIN)
Y: 1.0 Vp-p (75-ohm), C: 0.286 Vp-p (75-ohm)
AUDIO IN (RCA PIN JACK × 4)
0.5 Vrms (high impedance)
COMPONENT / RGB IN
Y / G (BNC)
with / sync 1.0 Vp-p (75-ohm)
P
B
/B (BNC), P
R
/R (BNC)
0.7 Vp-p (75-ohm)
AUDIO IN (RCA PIN JACK × 2)
0.5 Vrms (high impedance)
PC IN
(HIGH-DENSITY MINI-D-SUB 15PIN)
Y or G with / sync 1.0 Vp-p (75-ohm)
Y or G without / sync 0.7 Vp-p (75-ohm)
B / P
B
/ C
B
:0.7 Vp-p (75-ohm)
ORDER NO. MTNC070622CE
B34 Canada: D10
Содержание TH58PH10UK - 58" Plasma Panel
Страница 4: ...1 Applicable signals 4 TH 58PH10UK ...
Страница 20: ...7 2 Location of Lead Wiring 2 The lead wiring is dressed as shown in figure 20 TH 58PH10UK ...
Страница 23: ...8 4 Adjustment Volume Location 8 5 Test Point Location 23 TH 58PH10UK ...
Страница 27: ...9 2 IIC mode structure following items value is sample data 27 TH 58PH10UK ...
Страница 29: ...29 TH 58PH10UK ...
Страница 31: ...31 TH 58PH10UK ...
Страница 34: ...3 Remarks Above Fan function is operated during the fans are installed 34 TH 58PH10UK ...
Страница 37: ...12 Option Setting 37 TH 58PH10UK ...
Страница 67: ...14 Block and Schematic Diagram 14 1 Schematic Diagram Notes TH 58PH10UK 67 ...
Страница 118: ...NOTE TH 58PH10UK 118 ...
Страница 119: ...15 Parts Location 15 1 Exploded View 119 TH 58PH10UK ...
Страница 120: ...15 2 Escutcheon part location enlarged view 15 3 Fan part location enlarged view 120 TH 58PH10UK ...
Страница 121: ...15 4 Cable relation 121 TH 58PH10UK ...
Страница 122: ...15 5 Packing summary 122 TH 58PH10UK ...
Страница 124: ...17 Replacement Parts List 17 1 Replacement Parts List Notes 124 TH 58PH10UK ...